{"product_id":"ic200cpu002-ge-fanuc-versamax-cpu-module-compact-plc-processor","title":"IC200CPU002 GE Fanuc VersaMax CPU Module | Compact PLC Processor","description":"\u003ch3\u003e\u003cstrong\u003eCompact PLC Intelligence for Reliable Machine Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC200CPU002\u003c\/span\u003e\u003c\/strong\u003e is a compact \u003cstrong\u003eGE Fanuc VersaMax CPU Module\u003c\/strong\u003e designed to deliver dependable logic processing, flexible communications, and stable control performance.\u003c\/p\u003e\n\u003cp\u003eThe controller combines Flash memory, serial communication, real-time clock functions, and industrial reliability into a compact PLC platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC200CPU002\u003c\/span\u003e\u003c\/strong\u003e provides an efficient solution for distributed automation systems, OEM machinery, and standalone industrial control applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Engineering Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEngineering Capability\u003c\/th\u003e\n\u003cth\u003ePractical Advantage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e42 KB User Memory\u003c\/td\u003e\n\u003ctd\u003eSupports flexible PLC program development.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory Storage\u003c\/td\u003e\n\u003ctd\u003eProtects application programs during power interruptions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual Serial Interfaces\u003c\/td\u003e\n\u003ctd\u003eSimplifies communication with multiple industrial devices.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Real-Time Clock\u003c\/td\u003e\n\u003ctd\u003eSupports time-based automation functions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eHandles complex machine control applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200CPU002\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003eVersaMax\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Program Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-volatile Flash Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Languages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLadder Diagram (LD), Instruction List (IL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSNP Slave, RTU Slave, Serial I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Digital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Digital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun Mode Selector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRUN \/ STOP Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated RTC Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Battery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRTC Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime-of-Day Clock Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0023% at 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal or Vertical DIN Rail Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Recommendation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrounded DIN Rail Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCPU Operating Status and Communication Activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFloating Point Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal Data Processing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eWhere IC200CPU002 Performs Best\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFactory automation equipment\u003c\/li\u003e\n\u003cli\u003ePackaging machinery\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems\u003c\/li\u003e\n\u003cli\u003eWater treatment automation\u003c\/li\u003e\n\u003cli\u003eProcess control panels\u003c\/li\u003e\n\u003cli\u003eOEM machine control\u003c\/li\u003e\n\u003cli\u003eBuilding automation systems\u003c\/li\u003e\n\u003cli\u003eEnergy management applications\u003c\/li\u003e\n\u003cli\u003eRemote equipment monitoring\u003c\/li\u003e\n\u003cli\u003eDistributed PLC architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCPU reliability depends on more than processor performance. Stable power quality and proper communication wiring have a significant impact on long-term controller operation.\u003c\/p\u003e\n\u003cp\u003eDuring one conveyor retrofit project, intermittent communication errors appeared several times each shift. Engineers initially suspected controller hardware. Field inspection later revealed improper RS-485 cable termination. Correcting the wiring eliminated every communication interruption.\u003c\/p\u003e\n\u003cp\u003eFor industrial PLC installations, routine inspection of battery status and communication connections often prevents unexpected production downtime.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuilt-in Diagnostic Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic Function\u003c\/th\u003e\n\u003cth\u003eMaintenance Benefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Status Monitoring\u003c\/td\u003e\n\u003ctd\u003eProvides immediate operating feedback.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRUN \/ STOP Selector\u003c\/td\u003e\n\u003ctd\u003eSimplifies maintenance and commissioning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTC Battery Backup\u003c\/td\u003e\n\u003ctd\u003eMaintains critical system timing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Communication Status\u003c\/td\u003e\n\u003ctd\u003eAssists network troubleshooting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory Protection\u003c\/td\u003e\n\u003ctd\u003ePreserves application programs after power loss.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGround the DIN rail before installing the controller.\u003c\/li\u003e\n\u003cli\u003eSeparate communication cables from power wiring.\u003c\/li\u003e\n\u003cli\u003eInspect battery condition during scheduled maintenance.\u003c\/li\u003e\n\u003cli\u003eVerify communication parameters before downloading programs.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate cabinet ventilation for long-term stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for GE Fanuc VersaMax PLC systems.\u003c\/li\u003e\n\u003cli\u003eSupports distributed industrial automation architectures.\u003c\/li\u003e\n\u003cli\u003eCommunicates with serial industrial devices.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard VersaMax I\/O modules.\u003c\/li\u003e\n\u003cli\u003eSuitable for OEM equipment integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Shipping \u0026amp; Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200CPU002\u003c\/strong\u003e\u003c\/span\u003e CPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial anti-static packaging with reinforced cushioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-Month Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Services\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFedEx, UPS, DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDispatch Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrders typically ship within 24–48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow much PLC logic can the IC200CPU002 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 42 KB user memory is suitable for compact to medium-sized machine control programs requiring reliable execution and efficient memory utilization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should engineers verify before commissioning serial communications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm baud rate, protocol selection, node address, cable shielding, grounding, and termination before placing the controller into operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is Flash memory valuable in industrial PLC applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlash memory retains application programs without external power, reducing recovery time after unexpected shutdowns or maintenance activities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maintenance practice extends long-term controller reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExperienced engineers periodically inspect battery condition, communication terminals, cabinet temperature, and power supply stability during preventive maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should engineers evaluate whether IC200CPU002 is the right CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReview required I\/O capacity, communication interfaces, program size, installation space, future expansion plans, and compatibility with existing VersaMax hardware before selecting the controller.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Selection Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelect \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC200CPU002\u003c\/span\u003e\u003c\/strong\u003e for compact PLC applications requiring dependable processing performance.\u003c\/li\u003e\n\u003cli\u003eChoose this CPU when serial communication flexibility is essential.\u003c\/li\u003e\n\u003cli\u003eUse Flash memory advantages for projects requiring secure program retention.\u003c\/li\u003e\n\u003cli\u003eConsider future I\/O expansion requirements during system planning.\u003c\/li\u003e\n\u003cli\u003eImplement proper grounding and communication practices to maximize controller reliability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45013992964278,"sku":"IC200CPU002","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200CPU002.jpg?v=1786008589","url":"https:\/\/www.plcsparehub.com\/products\/ic200cpu002-ge-fanuc-versamax-cpu-module-compact-plc-processor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}