{"product_id":"ic200alg264-ge-fanuc-versamax-15-channel-current-input","title":"IC200ALG264 GE Fanuc VersaMax 15-Channel Current Input","description":"\u003ch3\u003e\u003cstrong\u003eIC200ALG264 | Analog Signal Acquisition Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1673b1;\"\u003eGE Fanuc IC200ALG264\u003c\/span\u003e\u003c\/strong\u003e is a 15-channel analog current input module from the \u003cstrong\u003eVersaMax I\/O series\u003c\/strong\u003e. It connects field current signals to a VersaMax PLC or compatible remote I\/O system. The module accepts \u003cstrong\u003e4–20mA and 0–20mA\u003c\/strong\u003e signals through 15 single-ended input channels. Its 15-bit conversion resolution supports detailed process signal acquisition. A maximum update rate of 7.5ms supports relatively fast monitoring of industrial process variables. The module uses the PLC backplane for its operating power. Field transmitters require their own external power supply. \u003cstrong\u003eEngineering Highlights\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e15 Input Channels:\u003c\/strong\u003e Single-ended current inputs in one group.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Input Ranges:\u003c\/strong\u003e Selectable 4–20mA or 0–20mA operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15-Bit Resolution:\u003c\/strong\u003e Supports fine analog signal conversion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Data Refresh:\u003c\/strong\u003e 7.5ms maximum module update rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Diagnostics:\u003c\/strong\u003e Detects internal power loss and open-wire conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Installation:\u003c\/strong\u003e Occupies one VersaMax I\/O slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Product Identity and System Position\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Corporate Association\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormer Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Intelligent Platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1673b1;\"\u003eIC200ALG264\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersaMax I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Current Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 Single-Ended Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne I\/O Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersaMax PLC \/ Remote I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Analog Input Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module converts field current signals into digital values for PLC processing. \u003cstrong\u003eInput Signal Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Range 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Range 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Grouping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne Group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConversion and Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADC Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 Bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution at 4–20mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5µA per count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution at 0–20mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.625µA per count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Accuracy at 25°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Accuracy Error at 25°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Accuracy Error at 0–60°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24Hz ±20% (-3dB corner frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Update Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5ms per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Isolation and Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput-to-Logic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250VAC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Withstand Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel-to-Channel Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGroup-to-Group Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Operating Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5VDC from PLC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100mA maximum at 5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Module Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics and Status\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen OK LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Power Diagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoss of Internal Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen-Wire Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable in 4–20mA mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Range Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarrier terminal jumper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Input Range Configuration Logic\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe input range depends on the jumper installed on the carrier terminals. \u003cstrong\u003eRange Selection Table\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJumper Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo jumper installed\u003c\/td\u003e\n\u003ctd\u003e4–20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumper installed between A16 and A17\u003c\/td\u003e\n\u003ctd\u003e0–20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhy This Configuration Matters\u003c\/strong\u003e The selected range affects the interpretation of every channel in the shared input group. For example, a 4–20mA transmitter uses 4mA as its live-zero reference. A 0–20mA transmitter uses zero current as its lower range boundary. The correct jumper configuration must match the connected field instruments. \u003cstrong\u003eEngineering Recommendation:\u003c\/strong\u003e Verify the carrier jumper before commissioning. Do not change the signal range based only on PLC software settings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Field Wiring and Installation Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1673b1;\"\u003eIC200ALG264\u003c\/span\u003e\u003c\/strong\u003e provides 15 single-ended inputs. All channels share a common return. \u003cstrong\u003eWiring Considerations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect each transmitter to its assigned input terminal.\u003c\/li\u003e\n\u003cli\u003eUse the designated common return terminal.\u003c\/li\u003e\n\u003cli\u003eProvide external power for field transmitters.\u003c\/li\u003e\n\u003cli\u003eKeep analog signal cables away from high-power conductors.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cables for analog connections.\u003c\/li\u003e\n\u003cli\u003eFollow the carrier terminal assignment in the hardware manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding\u003c\/strong\u003e The manufacturer recommends grounding the cable shield at the source device when practical. If source-side grounding is unavailable, ground the shield at the I\/O module. Use the appropriate auxiliary I\/O terminal where required. Avoid unintended multiple grounding paths. They can introduce circulating currents and signal interference. \u003cstrong\u003eBackplane Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the VersaMax carrier compatibility.\u003c\/li\u003e\n\u003cli\u003eConfirm that the backplane has sufficient 5V power capacity.\u003c\/li\u003e\n\u003cli\u003eVerify the module position and terminal arrangement.\u003c\/li\u003e\n\u003cli\u003eInstall the module according to the system documentation.\u003c\/li\u003e\n\u003cli\u003eCheck the OK LED after system startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Diagnostics and Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides diagnostic information for field-side circuit conditions. \u003cstrong\u003eLoss of Internal Power\u003c\/strong\u003e This diagnostic identifies a problem with the internally generated field-side power circuit. Recommended checks:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the module and carrier connections.\u003c\/li\u003e\n\u003cli\u003eCheck the backplane supply condition.\u003c\/li\u003e\n\u003cli\u003eInspect the field-side circuit connections.\u003c\/li\u003e\n\u003cli\u003eReview the PLC diagnostic status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOpen-Wire Detection\u003c\/strong\u003e The module supports open-wire detection for individual channels in 4–20mA mode. This feature helps identify broken signal wiring or disconnected current loops. Recommended checks:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the transmitter power supply.\u003c\/li\u003e\n\u003cli\u003eCheck loop wiring continuity.\u003c\/li\u003e\n\u003cli\u003eVerify terminal tightness.\u003c\/li\u003e\n\u003cli\u003eMeasure the loop current with a suitable instrument.\u003c\/li\u003e\n\u003cli\u003eConfirm the selected input range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOK LED Interpretation\u003c\/strong\u003e The green OK LED indicates successful module startup and configuration recognition. The indicator also confirms the required backplane power and internally generated field-side power conditions. If the LED remains OFF, inspect the module seating, carrier connections, backplane supply, and PLC configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | PLC Integration and Software Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supplies 15 words of analog input data to the host system. The CPU or Network Interface Unit performs the intelligent processing. The PLC application then maps the input data to engineering variables. \u003cstrong\u003eConfiguration Checks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the correct module identification.\u003c\/li\u003e\n\u003cli\u003eVerify the selected current input range.\u003c\/li\u003e\n\u003cli\u003eCheck the input data allocation.\u003c\/li\u003e\n\u003cli\u003eConfirm the channel-to-variable mapping.\u003c\/li\u003e\n\u003cli\u003eConfigure the required fault response.\u003c\/li\u003e\n\u003cli\u003eVerify the analog scaling in the PLC program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModule Identification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4–20mA Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFFFFB50F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0–20mA Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFFFFB40F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eLoss-of-Module Behavior\u003c\/strong\u003e The module supports software-configurable behavior when module operation is lost. The application can select default values or hold the last state. Engineers should evaluate the process safety requirements before selecting either option.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Environmental and EMC Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer's documentation specifies operation across an ambient range of 0–60°C for the stated accuracy limits. \u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy Reference at 25°C:\u003c\/strong\u003e ±0.3% typical, ±0.5% maximum of full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy Reference at 0–60°C:\u003c\/strong\u003e ±1% maximum of full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Derating:\u003c\/strong\u003e None specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEMC Performance\u003c\/strong\u003e Under severe RF interference conditions, the manufacturer identifies possible accuracy degradation to ±2%. The stated test condition references IEC 1000-4-3 at 10V\/m. For electrically noisy installations, engineers should review cable routing, shield grounding, cabinet bonding, and nearby variable-frequency drives.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | System Compatibility and Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1673b1;\"\u003eGE Fanuc IC200ALG264\u003c\/span\u003e\u003c\/strong\u003e belongs to the VersaMax I\/O hardware family. Before ordering, verify the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible VersaMax CPU or Network Interface Unit.\u003c\/li\u003e\n\u003cli\u003eSupported carrier and terminal arrangement.\u003c\/li\u003e\n\u003cli\u003eRequired 4–20mA or 0–20mA input configuration.\u003c\/li\u003e\n\u003cli\u003eAvailable backplane 5V current capacity.\u003c\/li\u003e\n\u003cli\u003ePLC firmware and programming software compatibility.\u003c\/li\u003e\n\u003cli\u003eRequired module identification and configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module documentation identifies VersaPro Version 2.0 or later and specified VersaMax CPU and NIU firmware requirements. Check the applicable hardware manual before integrating the module into an existing system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Certifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG264 documentation identifies industrial installation and hazardous-location markings. The documented product information includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL\/cUL recognition markings.\u003c\/li\u003e\n\u003cli\u003eCE marking.\u003c\/li\u003e\n\u003cli\u003eClass I, Division 2 hazardous-location markings.\u003c\/li\u003e\n\u003cli\u003eClass I, Zone 2 application markings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerify the exact module revision, nameplate, and applicable certification documentation before installation in a classified area.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Package Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eStandard product supply:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color: #1673b1;\"\u003eGE Fanuc IC200ALG264\u003c\/span\u003e Analog Current Input Module\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCarrier terminals, terminal blocks, jumpers, and additional installation accessories depend on the ordered configuration. Confirm the required carrier and wiring accessories separately when planning a replacement.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200ALG264.png?v=1794383023\" alt=\"\"\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013992833206,"sku":"IC200ALG264","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200ALG2642-1.jpg?v=1794383043","url":"https:\/\/www.plcsparehub.com\/products\/ic200alg264-ge-fanuc-versamax-15-channel-current-input","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}