{"product_id":"ic200alg263-ge-fanuc-versamax-15-bit-voltage-analog-input-module","title":"IC200ALG263 GE Fanuc VersaMax 15-Bit Voltage Analog Input Module","description":"\u003ch3\u003e\u003cb\u003eGE Fanuc VersaMax IC200ALG263 Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eGE Fanuc VersaMax IC200ALG263\u003c\/b\u003e\u003c\/span\u003e is a high-density 15-channel analog input module. Engineeers design this unit for precise voltage monitoring in industrial control systems. It accepts up to 15 single-ended inputs across a single isolated group. The module derives operational power directly from the backplane. Consequently, field transceivers require a separate external power supply. It provides 15 words of continuous analog data to the host CPU. Robust 1500 VAC frame ground isolation protects your system against field noise.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eGE Fanuc\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eSeries\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eVersaMax\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003ePart Number\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eIC200ALG263\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eNumber of Inputs\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e15 single-ended channels (1 group)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eMeasurement Range\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e-10 VDC to +10 VDC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e+\/- 15 bits\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eInput Impedance\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e100k Ohms minimum\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eUpdate Rate (Frequency Response)\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e7.5 ms full-scan refresh rate\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eSensitivity \u0026amp; Linearity\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eHigh-accuracy 15-bit conversion across full span\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eBackplane Power Requirements\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e5 VDC @ 150 mA maximum\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eIsolation Rating\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e250 VAC continuous user to logic; 1500 VAC user to frame ground (1 min)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eOperating Temperature Range\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e0°C to 60°C (32°F to 140°F) standard industrial\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eEnvironmental Endurance \u0026amp; Noise Immunity\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eIndustrial EMI\/RFI immunity; requires shielded twisted-pair cabling\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eSystem Compatibility\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eFits terminal-style, compact terminal-style, and connector-style I\/O carriers\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eCertifications\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eUL, CE, RoHS compliant industrial standards\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eAdvanced Diagnostic Capabilities\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eIC200ALG263\u003c\/b\u003e\u003c\/span\u003e features robust internal hardware monitoring to ensure data integrity.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIt continuously detects internal power loss on field-side circuits.\u003c\/li\u003e\n  \u003cli\u003eIt monitors the internal analog-to-digital (A\/D) conversion process for operational faults.\u003c\/li\u003e\n  \u003cli\u003eIt injects a known internal reference stimulus to verify conversion path accuracy.\u003c\/li\u003e\n  \u003cli\u003eIt halts scanning automatically if unexpected conversion errors occur three consecutive times.\u003c\/li\u003e\n  \u003cli\u003eIt turns off the OK LED to notify operators of critical module failures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eInstallation \u0026amp; Cable Wiring Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the module onto a compatible \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eVersaMax\u003c\/b\u003e\u003c\/span\u003e I\/O carrier before applying backplane power.\u003c\/li\u003e\n  \u003cli\u003eUse high-quality shielded twisted-pair cables for all 15 input channel connections.\u003c\/li\u003e\n  \u003cli\u003eGround signal shielding at one end only to eliminate ground loop interference.\u003c\/li\u003e\n  \u003cli\u003eProvide an external 24 VDC supply to power system field transceivers.\u003c\/li\u003e\n  \u003cli\u003eVerify that field wiring voltage strictly stays within the +\/-10 VDC operational limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eCommissioning \u0026amp; Maintenance Tips\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCheck the front-panel OK LED during initial system power-up.\u003c\/li\u003e\n  \u003cli\u003eA solid green OK LED confirms successful backplane configuration and hardware initialization.\u003c\/li\u003e\n  \u003cli\u003eNote that the OK LED does not display external sensor or wiring faults.\u003c\/li\u003e\n  \u003cli\u003eVerify analog registers in software during active commissioning to validate field voltage levels.\u003c\/li\u003e\n  \u003cli\u003eReplace damaged sensor lines promptly if signal drift appears in diagnostic software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eTypical Application Scenarios\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eGE Fanuc IC200ALG263\u003c\/b\u003e\u003c\/span\u003e performs reliably across multiple industrial automation sectors:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eProcess Control:\u003c\/b\u003e Monitoring multi-point +\/-10V transmitter outputs in chemical processing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eFactory Automation:\u003c\/b\u003e Tracking position feedback from linear voltage transducers on assembly lines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003ePower \u0026amp; Energy:\u003c\/b\u003e Recording system voltage signals in remote power distribution panels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eHVAC Monitoring:\u003c\/b\u003e Gathering multi-zone damper position feedback across large facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003ePackaging List \u0026amp; Express Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003ePackage Contents:\u003c\/b\u003e 1x \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eGE Fanuc IC200ALG263\u003c\/b\u003e\u003c\/span\u003e Analog Input Module, factory sealed in anti-static packaging.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e Includes full 12-Month Comprehensive Warranty cover.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eFast Dispatch:\u003c\/b\u003e Ships out within 24 to 48 hours from order confirmation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eCourier Partners:\u003c\/b\u003e Worldwide express delivery via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eOur field engineering team regularly reviews \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eVersaMax\u003c\/b\u003e\u003c\/span\u003e system deployments. In one notable plant retrofit, a customer reported intermittent voltage spikes on channel 4 of their \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eIC200ALG263\u003c\/b\u003e\u003c\/span\u003e. Our team diagnosed an ungrounded cable shield routing near a high-voltage variable frequency drive. Grounding the shielded twisted-pair cable at the carrier terminal resolved the interference immediately. The module's built-in self-test feature helps isolate real A\/D conversion faults from external field noise quickly.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eSelection Guide \u0026amp; Selection Considerations\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eSignal Type:\u003c\/b\u003e Choose \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eIC200ALG263\u003c\/b\u003e\u003c\/span\u003e specifically for +\/-10 VDC voltage signals. Use current modules for 4-20mA loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eChannel Density:\u003c\/b\u003e This unit offers 15 single-ended channels. Ensure your sensors share a common ground reference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eCarrier Selection:\u003c\/b\u003e Select terminal-style, compact terminal-style, or connector-style carriers based on cabinet space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: Does the \u003cspan style=\"color: #0056b3;\"\u003eIC200ALG263\u003c\/span\u003e require an external power supply for basic backplane operation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The backplane 5 VDC supply powers the module directly. However, field transceivers require external power.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: What does it mean when the OK LED turns off during operation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: It indicates a backplane configuration failure, power loss, or three consecutive internal diagnostic test failures.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Why am I reading unstable voltage values on my PLC programming software?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Unshielded cables or ground loops usually cause instability. Ensure you use grounded shielded twisted-pair cables.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Can I connect current (4-20mA) inputs directly to this module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. This module only accepts -10 VDC to +10 VDC inputs natively. You must use precision external shunt resistors for current inputs.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013999976630,"sku":"IC200ALG263","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200ALG263.jpg?v=1790666732","url":"https:\/\/www.plcsparehub.com\/products\/ic200alg263-ge-fanuc-versamax-15-bit-voltage-analog-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}