{"product_id":"ic200alg230-ge-fanuc-versamax-4-channel-analog-input-module","title":"IC200ALG230 GE Fanuc VersaMax 4-Channel Analog Input Module","description":"\u003ch3\u003eIC200ALG230 GE Fanuc VersaMax 4-Channel Analog Input Module\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200ALG230\u003c\/strong\u003e is a high-precision Analog Input Module engineered for the \u003cstrong\u003eVersaMax\u003c\/strong\u003e modular automation platform, originally designed by \u003cstrong\u003eGE Fanuc\u003c\/strong\u003e and currently supported under \u003cstrong\u003eEmerson Automation\u003c\/strong\u003e. This compact hardware card provides four (4) single-ended analog input channels capable of processing both voltage and current signals, including unipolar\/bipolar voltage spans and standard industrial 4-20 mA current loops.\u003c\/p\u003e\n\u003cp\u003eFeaturing a 12-bit analog-to-digital converter, hardware jumper configuration blocks, and robust optical isolation, the \u003cstrong\u003eIC200ALG230\u003c\/strong\u003e delivers dependable signal conversion for complex industrial measurement loops. It draws operating power directly from the VersaMax rack backplane, eliminating the need for an external auxiliary power supply while maintaining fast filter response times.\u003c\/p\u003e\n\u003ch3\u003eMECE Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \/ Manufacturer:\u003c\/strong\u003e \u003cstrong\u003eGE Fanuc\u003c\/strong\u003e \/ GE Intelligent Platforms \/ Emerson Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003e\u003cstrong\u003eVersaMax\u003c\/strong\u003e\u003c\/a\u003e modular control architecture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e \u003cstrong\u003eIC200ALG230\u003c\/strong\u003e (VersaMax Analog Input Module)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Channel Count:\u003c\/strong\u003e 4 single-ended analog input channels in 1 group\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Input Signals:\u003c\/strong\u003e 4-20 mA current, 0 to 10 VDC unipolar voltage, and +\/-10 VDC bipolar voltage (default)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConverter Resolution:\u003c\/strong\u003e 12 bits (equivalent to 4 uA = 8 counts for current; 2.5 mV = 8 counts for voltage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse \u0026amp; Update Rates:\u003c\/strong\u003e 0.4 ms nominal update rate with a 5.0 ms filter response time\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power Draw:\u003c\/strong\u003e 125 mA at 5 VDC output (supplied directly from rack power supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Method:\u003c\/strong\u003e 2 physical onboard mode\/range selection jumpers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Reaction Modes:\u003c\/strong\u003e Configurable to hold last known state or transition to a pre-defined fallback value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Rating:\u003c\/strong\u003e 250 VAC continuous optical isolation; 1500 VAC dielectric strength for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Carrier Bases:\u003c\/strong\u003e IC200CHS001, 002, 003, 005, IC200CHS022, 025; Terminal blocks IC200TBM001, 002, 005\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Lifecycle Status:\u003c\/strong\u003e Mature industrial automation hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Hardware Setup\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure all system rack power is fully isolated and switched off before snapping the \u003cstrong\u003eIC200ALG230\u003c\/strong\u003e module onto its carrier base.\u003c\/li\u003e\n\u003cli\u003eConfigure the two physical onboard jumpers correctly to match your application requirements for current versus voltage and unipolar versus bipolar input modes.\u003c\/li\u003e\n\u003cli\u003eTerminate field signal wires into compatible VersaMax terminal blocks (such as IC200TBM001 or IC200CHS series carriers).\u003c\/li\u003e\n\u003cli\u003eGround signal cable shields securely at the source transmitter or at the module terminal strip to minimize electromagnetic noise coupling.\u003c\/li\u003e\n\u003cli\u003eVerify backplane seating and check that module retention latches are securely locked into position.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaintenance \u0026amp; Diagnostic Troubleshooting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitor the front-panel INT PWR LED to confirm internal field power generation is healthy.\u003c\/li\u003e\n\u003cli\u003eObserve the OK status LED to verify active backplane communication and processor handshaking.\u003c\/li\u003e\n\u003cli\u003eCheck diagnostic registers in your programming software if the module enters a fault state to verify configuration parameter validity.\u003c\/li\u003e\n\u003cli\u003eInspect analog signal wiring and shielding periodically if fluctuating process values or ground loop interference are detected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility \u0026amp; Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC Backplanes:\u003c\/strong\u003e Fully compatible with standard \u003cstrong\u003eVersaMax\u003c\/strong\u003e snap-together carrier bases and CPU backplane racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming Environment:\u003c\/strong\u003e Configured seamlessly using Proficy Machine Edition or legacy GE programming software suites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Sources:\u003c\/strong\u003e Optimized for interfacing with industrial transmitters, temperature transducers, pressure sensors, and flow meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics, Certification \u0026amp; Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Assurance:\u003c\/strong\u003e Fully tested and inspected hardware backed by a comprehensive \u003cstrong\u003e12-month\u003c\/strong\u003e replacement warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Shipping Partners:\u003c\/strong\u003e Fast, secure worldwide transit via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling \u0026amp; Dispatch Window:\u003c\/strong\u003e Guaranteed processing and dispatch within \u003cstrong\u003e24 to 48 hours\u003c\/strong\u003e of order verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Packaging:\u003c\/strong\u003e Enclosed in anti-static shielding bags and cushioned industrial packaging boxes to ensure safe arrival.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Industrial Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess control loops monitoring tank level, pressure, and flow rates in water treatment facilities.\u003c\/li\u003e\n\u003cli\u003eChemical dosing skids requiring precise 4-20 mA sensor feedback tracking.\u003c\/li\u003e\n\u003cli\u003eHVAC environmental monitoring systems capturing multi-channel analog temperature and humidity readings.\u003c\/li\u003e\n\u003cli\u003eManufacturing test benches acquiring high-resolution voltage signals from mechanical load cells.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/h3\u003e\n\u003cp\u003eAutomation technicians deploying legacy \u003cstrong\u003eVersaMax\u003c\/strong\u003e analog cards often encounter calibration drift or erratic input readings when switching between current and voltage modes if the physical hardware jumpers are overlooked. Because the \u003cstrong\u003eIC200ALG230\u003c\/strong\u003e relies on manual jumper settings on the module board alongside software configuration, a mismatch between the jumper position and software range scaling will cause severe conversion errors.\u003c\/p\u003e\n\u003cp\u003eFor example, a wastewater treatment plant technician replaced a faulted analog card with a spare \u003cstrong\u003eIC200ALG230\u003c\/strong\u003e but neglected to move the internal mode jumpers from the default bipolar voltage setting to the required 4-20 mA current setting. Although the software configuration was updated, the hardware jumper mismatch caused constant out-of-range scaling faults. Verifying and repositioning the physical jumpers instantly aligned the hardware conversion scale and restored accurate loop feedback.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhy am I getting scaling or out-of-range errors after wiring a 4-20mA transmitter?\u003c\/h4\u003e\n\u003cp\u003eCheck that the physical onboard configuration jumpers are correctly set for current operation; software settings alone will not override incorrect hardware jumper placement.\u003c\/p\u003e\n\u003ch4\u003eDoes the IC200ALG230 module require an external 24VDC power supply?\u003c\/h4\u003e\n\u003cp\u003eNo, this module draws all necessary operating current directly from the VersaMax rack backplane (125 mA at 5 VDC), simplifying panel power distribution.\u003c\/p\u003e\n\u003ch4\u003eWhat happens to input data if a module communication error occurs?\u003c\/h4\u003e\n\u003cp\u003eYou can configure the module through programming software either to hold its last known good input state or transition to a pre-defined fallback value during an error.\u003c\/p\u003e\n\u003ch4\u003eHow do I choose the correct terminal style carrier base for this module?\u003c\/h4\u003e\n\u003cp\u003eYou can pair the module with standard VersaMax compact terminal-style carriers like the IC200CHS001, IC200CHS002, or IC200CHS022 depending on your cabinet wiring preferences.\u003c\/p\u003e\n\u003ch4\u003eWhat is the purpose of the INT PWR and OK LEDs on the front panel?\u003c\/h4\u003e\n\u003cp\u003eThe INT PWR LED indicates internal power availability, while the OK LED verifies that backplane communication and module health are functioning normally.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013999878326,"sku":"IC200ALG230","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200ALG230-3.jpg?v=1788857506","url":"https:\/\/www.plcsparehub.com\/products\/ic200alg230-ge-fanuc-versamax-4-channel-analog-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}