{"product_id":"horiba-sec-z514mgx-z500-series-digital-mass-flow-controller","title":"HORIBA SEC-Z514MGX Z500 Series Digital Mass Flow Controller","description":"\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0000FF;\"\u003eHORIBA SEC-Z514MGX\u003c\/span\u003e\u003c\/strong\u003e is a digital mass flow controller from the \u003cstrong\u003e\u003cspan style=\"color: #0000FF;\"\u003eZ500 Series\u003c\/span\u003e\u003c\/strong\u003e. It provides precise gas flow regulation for semiconductor manufacturing and industrial process systems.\u003c\/p\u003e\n\n\u003cp\u003eThis model combines thermal mass flow measurement with an integrated control valve. Its variable PID control system delivers a full-scale response within one second. Engineers can use it to maintain stable gas delivery during process transitions.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSEC-Z514MGX\u003c\/strong\u003e supports DeviceNet communication and a 24 VDC power supply. Its wetted components use polished 316L stainless steel. These features support reliable operation in demanding gas delivery environments.\u003c\/p\u003e\n\n\u003cp\u003eHORIBA also offers the \u003cstrong\u003eSEF-Z514MGX\u003c\/strong\u003e as the corresponding mass flow meter configuration. The SEC model regulates flow, while the SEF model measures flow without integrated control valve regulation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHORIBA STEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eZ500 Series \/ Z500X\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSEC-Z514MGX\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeter Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSEF-Z514MGX\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Mass Flow Controller \/ Mass Flow Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 4.0 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolished 316L Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 to 45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Fitting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4-inch VCR equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree orientation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFlow Range and Measurement Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSEC-Z514MGX\u003c\/strong\u003e supports multiple nitrogen-equivalent full-scale flow configurations. Actual flow capacity depends on the selected range and process gas.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eRange Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eN2 Equivalent Full Scale\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#R01\u003c\/td\u003e\n\u003ctd\u003e10 SCCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#R1.5\u003c\/td\u003e\n\u003ctd\u003e17.5 SCCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#01\u003c\/td\u003e\n\u003ctd\u003e30 SCCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#1.5\u003c\/td\u003e\n\u003ctd\u003e55 SCCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#02\u003c\/td\u003e\n\u003ctd\u003e100 SCCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#2.5\u003c\/td\u003e\n\u003ctd\u003e175 SCCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#03\u003c\/td\u003e\n\u003ctd\u003e300 SCCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#3.5\u003c\/td\u003e\n\u003ctd\u003e550 SCCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#04\u003c\/td\u003e\n\u003ctd\u003e1 SLM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#4.5\u003c\/td\u003e\n\u003ctd\u003e1.75 SLM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#05\u003c\/td\u003e\n\u003ctd\u003e3 SLM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#5.5\u003c\/td\u003e\n\u003ctd\u003e5.5 SLM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e#06\u003c\/td\u003e\n\u003ctd\u003e10 SLM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eMeasurement and Control Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Range:\u003c\/strong\u003e 2–100% of full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0–100% of full scale for the SEF meter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy Above 25% F.S.:\u003c\/strong\u003e ±1.0% of setpoint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy At or Below 25% F.S.:\u003c\/strong\u003e ±0.25% of full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e ≤1 second across the full flow range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e ≤±0.5% of full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e ≤±0.2% of full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Valve Leakage:\u003c\/strong\u003e ≤2% of full scale.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePressure and Environmental Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Differential Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50–300 kPa(d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh-Flow Differential Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–300 kPa(d) for #5.5 and #06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEF Differential Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤300 kPa(d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 kPa(g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 kPa(g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHelium Leak Integrity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤5 × 10⁻¹² Pa·m³\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e The differential pressure requirements vary by flow range. Verify upstream and downstream pressure conditions before installation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eElectrical and Communication Features\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Interface:\u003c\/strong\u003e DeviceNet protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 24 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 4.0 VA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Variable PID control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Configuration:\u003c\/strong\u003e Normally open or normally closed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe supplied configuration determines the available communication and electrical options. Confirm the complete model code before integrating the unit with a PLC or gas delivery controller.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eModel Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe SEC-Z514MGX model code identifies the product family and configuration. The following options require confirmation against the manufacturer's complete ordering information.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEC:\u003c\/strong\u003e Mass flow controller configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEF:\u003c\/strong\u003e Mass flow meter configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZ514MGX:\u003c\/strong\u003e Model designation within the Z500 family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Range:\u003c\/strong\u003e Selected through the corresponding range configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Action:\u003c\/strong\u003e Normally open (O) or normally closed (C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFitting:\u003c\/strong\u003e Standard 1\/4-inch VCR equivalent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eOptional fitting configurations include 1.125-inch IGS and 1.5-inch IGS. Confirm the selected fitting and valve action before ordering.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the Model:\u003c\/strong\u003e Check the model code, gas type, flow range, and valve action.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Connections:\u003c\/strong\u003e Examine the fittings and sealing surfaces before assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm Gas Compatibility:\u003c\/strong\u003e Verify wetted material compatibility with the process gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Pressure:\u003c\/strong\u003e Maintain the specified differential pressure during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect Power:\u003c\/strong\u003e Provide a regulated 24 VDC supply within the equipment requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect DeviceNet:\u003c\/strong\u003e Verify network wiring, node address, and communication settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Gas Lines:\u003c\/strong\u003e Perform an appropriate leak test before introducing process gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart Operation:\u003c\/strong\u003e Apply the approved startup procedure and inspect flow stability.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eProper commissioning helps maintain measurement accuracy and stable gas delivery. Engineers should verify the following conditions:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eConfirm the correct gas conversion and full-scale range.\u003c\/li\u003e\n\u003cli\u003eCheck zero-flow readings before applying the process gas.\u003c\/li\u003e\n\u003cli\u003eVerify the DeviceNet connection and controller communication.\u003c\/li\u003e\n\u003cli\u003eCompare actual flow readings with a suitable reference instrument.\u003c\/li\u003e\n\u003cli\u003eInspect pressure stability during low-flow and high-flow operation.\u003c\/li\u003e\n\u003cli\u003eCheck valve response when changing flow setpoints.\u003c\/li\u003e\n\u003cli\u003eInspect fittings and seals during scheduled maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDo not adjust PID parameters without reviewing the application requirements. Avoid introducing contamination during gas-line maintenance. Follow the manufacturer's procedures for calibration and internal servicing.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility and Application\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eHORIBA SEC-Z514MGX\u003c\/strong\u003e supports gas flow control systems that require DeviceNet communication and compatible 24 VDC power.\u003c\/p\u003e\n\n\u003cp\u003eTypical application areas include:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemiconductor Manufacturing:\u003c\/strong\u003e Precise gas delivery for process chambers and gas panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThin-Film Deposition:\u003c\/strong\u003e Stable gas flow during deposition processes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtching Systems:\u003c\/strong\u003e Controlled delivery of compatible process gases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Gas Systems:\u003c\/strong\u003e Flow regulation in automated gas distribution equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResearch Equipment:\u003c\/strong\u003e Gas measurement and control in laboratory process systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eBefore system integration, verify the PLC interface, DeviceNet configuration, gas compatibility, fitting dimensions, and pressure requirements. RS-485 and analog interfaces depend on the specific product configuration. Do not assume their availability on every SEC-Z514MGX unit.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe supplied technical information identifies DeviceNet communication and ODVA-conforming power requirements. It does not establish specific safety or hazardous-area certifications.\u003c\/p\u003e\n\n\u003cp\u003eRequest the applicable manufacturer's declaration and product documentation when your installation requires regulatory approval. Verify the exact configuration before specifying compliance requirements.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × HORIBA SEC-Z514MGX Digital Mass Flow Controller, according to the ordered configuration.\u003c\/li\u003e\n\u003cli\u003eProduct identification and model information.\u003c\/li\u003e\n\u003cli\u003eStandard accessories, only when included in the confirmed order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor the SEF-Z514MGX configuration, the supplied unit is a mass flow meter. Confirm the package contents and accessories with the supplier before purchase.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What is the difference between SEC-Z514MGX and SEF-Z514MGX?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe SEC-Z514MGX combines mass flow measurement with an integrated control valve. The SEF-Z514MGX measures mass flow without providing the same integrated flow regulation function.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How should engineers select the correct flow range?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFirst, identify the process gas and required operating flow. Then select a nitrogen-equivalent full-scale range that accommodates normal operating conditions. Avoid choosing a range that places most operating points near the minimum control limit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Why can actual flow differ from the nitrogen-equivalent rating?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe listed ranges use nitrogen as the reference gas. Different gases have different physical properties and conversion requirements. Engineers should confirm the correct gas calibration before commissioning.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: What should engineers check when the controller responds slowly?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eStart by checking differential pressure and gas supply stability. Next, inspect DeviceNet communication and the requested setpoint. Confirm the selected gas configuration and verify that the process line has no restrictions. These checks help isolate pneumatic and control-related problems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: Can the SEC-Z514MGX connect directly to any PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eNo. The PLC must support a compatible DeviceNet interface or use an appropriate network gateway. Engineers should also verify node addressing, communication parameters, power requirements, and control data mapping.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ6: How should buyers choose between normally open and normally closed valves?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eConsider the required gas-line behavior during power loss or control interruption. Normally open and normally closed configurations provide different default valve positions. Select the option that matches the process safety philosophy and equipment design.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ7: What information should buyers provide when requesting a quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eProvide the complete model number, process gas, required full-scale flow, valve action, fitting type, and communication interface. Also specify the operating pressure and temperature. These details help prevent configuration mismatches.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eWhy Choose Global PLC Spare HUB?\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eGlobal PLC Spare HUB supports industrial automation users with component selection and sourcing assistance.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical Support:\u003c\/strong\u003e Assistance with model identification and configuration checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Sourcing:\u003c\/strong\u003e Support for industrial control and process instrumentation requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-Month Warranty:\u003c\/strong\u003e Warranty coverage according to the confirmed sales terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Options:\u003c\/strong\u003e International shipping through FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Arrangement:\u003c\/strong\u003e Typical shipping arrangement within 24–48 hours, subject to stock confirmation and order processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eRequest a Quote Today\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eLooking for the \u003cstrong\u003eHORIBA SEC-Z514MGX\u003c\/strong\u003e or \u003cstrong\u003eSEF-Z514MGX\u003c\/strong\u003e? Contact Global PLC Spare HUB with your required gas, flow range, and connection details. Our team can assist with model verification and quotation inquiries.\u003c\/p\u003e\n","brand":"HORIBA","offers":[{"title":"Default Title","offer_id":68018403934390,"sku":"SEC-Z514MGX","price":203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/SEC-Z517_1.jpg?v=1794203423","url":"https:\/\/www.plcsparehub.com\/products\/horiba-sec-z514mgx-z500-series-digital-mass-flow-controller","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}