{"product_id":"honeywell-xnxr1ss-hcl-sensor-cartridge-xnx-s3000-series","title":"Honeywell XNXR1SS HCl Sensor Cartridge XNX \u0026 S3000 Series","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNXR1SS\u003c\/strong\u003e\u003c\/span\u003e is a plug-and-play replaceable electrochemical cell sensor cartridge.\u003c\/p\u003e\n\u003cp\u003eThis unit provides accurate continuous monitoring of Hydrogen Chloride (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHCl\u003c\/strong\u003e\u003c\/span\u003e) gas in hazardous industrial environments.\u003c\/p\u003e\n\u003cp\u003eEngineered for high accuracy, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNXR1SS\u003c\/strong\u003e\u003c\/span\u003e integrates seamlessly with \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX\u003c\/strong\u003e\u003c\/span\u003e and \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eS3000\u003c\/strong\u003e\u003c\/span\u003e transmitter series.\u003c\/p\u003e\n\u003cp\u003eIt supports flexible target gas detection ranges from 0-10ppm up to 0-20ppm with precise 1.0ppm user adjustments.\u003c\/p\u003e\n\u003cp\u003eFactory-calibrated construction allows rapid field installation without complex tools or special bench equipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%; height: 372.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 30%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70%; height: 19.6px;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNXR1SS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX Series\u003c\/strong\u003e\u003c\/span\u003e \u0026amp; \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eS3000 Series\u003c\/strong\u003e\u003c\/span\u003e Cartridge Family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\"\u003eToxic Gas Sensor Cartridge (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHCl\u003c\/strong\u003e\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e\u003cstrong\u003eTarget Gas\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\"\u003eHydrogen Chloride (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHCl\u003c\/strong\u003e\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e0 to 10ppm standard (User adjustable from 10.0 to 20.0ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e1.0ppm increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\"\u003eT90 \u0026lt; 30 seconds for quick threat detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px;\"\u003e\u003cstrong\u003eSensitivity \u0026amp; Linearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.2px;\"\u003eLinear output response across full measurement scale (\u0026lt; ±2% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.2px;\"\u003e-20°C to +50°C (-4°F to +122°F) continuous operating ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px;\"\u003e\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.2px;\"\u003eIP66 hazardous area enclosure sealing against dust and heavy spray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px;\"\u003e\u003cstrong\u003eInterference Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.2px;\"\u003eCross-sensitivity filter suppresses false alarms from common industrial gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px;\"\u003e\u003cstrong\u003eSelf-Diagnostic Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.2px;\"\u003eContinuous cell health tracking, electrolyte monitoring, and zero drift detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6px;\"\u003e3.0 kg (6.61 lbs) complete with protective factory packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNXR1SS\u003c\/strong\u003e\u003c\/span\u003e module supports direct insertion into the following transmitter enclosures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell XNX Universal Transmitter Series\u003c\/strong\u003e\u003c\/span\u003e (All signal output option boards)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell Searchpoint Optima \/ S3000 Series\u003c\/strong\u003e\u003c\/span\u003e Gas Detection Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIntegrated memory chips inside the cartridge automatically transfer calibration data, gas type, and span factors directly to the transmitter host.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Commissioning Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInstalling or hot-swapping the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNXR1SS\u003c\/strong\u003e\u003c\/span\u003e cartridge requires minimal maintenance effort during routine plant updates:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate local transmitter power or initiate maintenance mode on your safety instrumented system (SIS).\u003c\/li\u003e\n\u003cli\u003eUnscrew the protective weatherproof cap from the transmitter housing base.\u003c\/li\u003e\n\u003cli\u003eAlign the internal alignment pin of the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNXR1SS\u003c\/strong\u003e\u003c\/span\u003e module with the transmitter socket.\u003c\/li\u003e\n\u003cli\u003ePush the cartridge firmly until the locking tab fully engages.\u003c\/li\u003e\n\u003cli\u003eReinstall the sensor cover tightly to preserve the IP66 environmental seal.\u003c\/li\u003e\n\u003cli\u003ePower up the transmitter; the host automatically reads sensor coefficients from onboard EEPROM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; Field Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAdvanced diagnostic features built into the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNXR1SS\u003c\/strong\u003e\u003c\/span\u003e ensure maximal plant uptime:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eActive cell monitoring alerts technicians before sensor baseline drift impacts detection accuracy.\u003c\/li\u003e\n\u003cli\u003ePre-calibrated internal profiles eliminate the need for immediate field span gas calibration upon swap.\u003c\/li\u003e\n\u003cli\u003eOnboard diagnostics issue warning codes to the host controller when cell output degrades below critical thresholds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications \u0026amp; Standards Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell XNXR1SS\u003c\/strong\u003e\u003c\/span\u003e sensor complies with global industrial safety and hazardous location standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eATEX \/ IECEx zone approval for explosive gas atmospheres\u003c\/li\u003e\n\u003cli\u003eUL and CSA approval for hazardous locations Class I, Division 1\u003c\/li\u003e\n\u003cli\u003eSIL2 rating suitable for integrated safety shutdown systems\u003c\/li\u003e\n\u003cli\u003eCE compliant for electromagnetic compatibility (EMC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Insights \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEngineering teams at Global PLC Spare HUB consistently select the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell XNXR1SS\u003c\/strong\u003e\u003c\/span\u003e for high-corrosion plant installations.\u003c\/p\u003e\n\u003cp\u003eDuring a chemical plant upgrade in Texas, field technicians replaced aging toxic gas cells with \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNXR1SS\u003c\/strong\u003e\u003c\/span\u003e cartridges in under five minutes per unit without recalibrating host transmitter controllers.\u003c\/p\u003e\n\u003cp\u003eThe plug-and-play architecture reduced system commissioning downtime by 60% compared to traditional wired sensor replacements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell XNXR1SS\u003c\/strong\u003e\u003c\/span\u003e toxic gas cartridge provides reliable service across heavy industrial environments:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChemical processing facilities and hazardous material storage vaults\u003c\/li\u003e\n\u003cli\u003eSemiconductor manufacturing cleanrooms using specialty etching gases\u003c\/li\u003e\n\u003cli\u003ePharmaceutical synthesis plants handling corrosive acidic vapors\u003c\/li\u003e\n\u003cli\u003eIndustrial wastewater treatment facilities with specialized gas scrubber lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics \u0026amp; Quality Guarantee\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe ensure fast delivery and reliable quality for all automation spares:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Time:\u003c\/strong\u003e Ships within 24 to 48 hours directly from stock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Express Partners:\u003c\/strong\u003e Express global delivery via DHL, FedEx, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Complete 12-Month comprehensive warranty cover included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Checklist\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEvery shipment contains factory-verified original items:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHoneywell XNXR1SS\u003c\/strong\u003e\u003c\/span\u003e Replaceable \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHCl\u003c\/strong\u003e\u003c\/span\u003e Sensor Cartridge\u003c\/li\u003e\n\u003cli\u003eFactory Calibration Certificate\u003c\/li\u003e\n\u003cli\u003eInstallation instruction manual and sealing O-ring set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSelection Guide \u0026amp; Buyer Advice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFollow these quick steps to choose the correct sensor cartridge for your plant safety setup:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm target gas type matches Hydrogen Chloride (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHCl\u003c\/strong\u003e\u003c\/span\u003e) requirements.\u003c\/li\u003e\n\u003cli\u003eVerify host transmitter series; ensure compatibility with \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eXNX\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eS3000\u003c\/strong\u003e\u003c\/span\u003e hardware.\u003c\/li\u003e\n\u003cli\u003eCheck operating range needs; the standard setting is 0-10ppm, adjustable up to 20ppm.\u003c\/li\u003e\n\u003cli\u003eEnsure environmental temperature range falls within -20°C to +50°C for stable operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I change the detection range from 10ppm to 15ppm directly in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. You can adjust the detection range through the host transmitter UI in 1.0ppm steps up to 20ppm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is field calibration required immediately after inserting a new XNXR1SS module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The unit arrives factory-calibrated and automatically transfers calibration factors to the transmitter host.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the cell handle high-humidity industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The IP66 protective enclosure and specialized cell hydrophobic membrane prevent moisture intrusion during operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What express carrier options do you provide for urgent breakdowns?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: We ship orders worldwide using premium courier services including FedEx, DHL, and UPS within 24-48 hours.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45379990814902,"sku":"XNXR1SS","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/XNXO1SS.jpg?v=1787561502","url":"https:\/\/www.plcsparehub.com\/products\/honeywell-xnxr1ss-hcl-sensor-cartridge-xnx-s3000-series","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}