{"product_id":"honeywell-hc900-900h01-0102-digital-output-relay-module-8-channel","title":"Honeywell HC900 900H01-0102 Digital Output Relay Module 8-Channel","description":"\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003e900H01-0102\u003c\/span\u003e\u003c\/strong\u003e is essential for high-current requirements. Its mechanical relay design offers physical circuit isolation. This feature is superior to solid-state outputs for safety interlocks. Engineering data confirms high reliability in harsh electrical environments. It is compatible with \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003eHC900\u003c\/span\u003e\u003c\/strong\u003e C30, C50, and C70 controllers.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: Honeywell\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003e900H01-0102\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSeries: \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003eHC900\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Parameters\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Type: Digital Relay (SPST)\u003c\/li\u003e\n\u003cli\u003eNumber of Channels: 8 Outputs\u003c\/li\u003e\n\u003cli\u003eAC Voltage Range: Up to 250 VAC\u003c\/li\u003e\n\u003cli\u003eDC Voltage Range: Up to 30 VDC\u003c\/li\u003e\n\u003cli\u003eCurrent Rating: 4 Amps per relay maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003eHumidity: 5% to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: 2500 VAC (input to output)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerformance Data\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eResponse Time: 10 ms maximum (Turn-on\/off)\u003c\/li\u003e\n\u003cli\u003eCoil Consumption: 1.2 W per relay\u003c\/li\u003e\n\u003cli\u003eAnti-Interference: High galvanic isolation design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003eHC900\u003c\/span\u003e\u003c\/strong\u003e rack power is off.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the backplane connector pins.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the top and bottom fasteners.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Convenience\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eThe module supports easy removal without tools.\u003c\/li\u003e\n\u003cli\u003eFront-facing LEDs show the status of each relay.\u003c\/li\u003e\n\u003cli\u003eNo periodic calibration is required for relay outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMotor starter contactor activation.\u003c\/li\u003e\n\u003cli\u003eSolenoid valve control in fluid systems.\u003c\/li\u003e\n\u003cli\u003eExternal alarm and notification lamp switching.\u003c\/li\u003e\n\u003cli\u003eSafety interlock circuits for industrial furnaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics \u0026amp; Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time LED indicators for channel logic states.\u003c\/li\u003e\n\u003cli\u003eIntegrated health monitoring via the \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003eHC900\u003c\/span\u003e\u003c\/strong\u003e CPU.\u003c\/li\u003e\n\u003cli\u003eInput-to-output isolation protects internal controller logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics \u0026amp; Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Time\u003c\/strong\u003e: 24-48 hours after payment confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Methods\u003c\/strong\u003e: FedEx, UPS, DHL express services.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 12 months comprehensive coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePacking List\u003c\/strong\u003e: One \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003eHoneywell 900H01-0102\u003c\/span\u003e\u003c\/strong\u003e, Factory Test Report.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ \u0026amp; Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQuestion: Can I switch 220V AC and 24V DC on the same module?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAnswer: Yes, the relays are independent and support mixed voltages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQuestion: What is the benefit of the 4A rating compared to standard modules?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAnswer: It allows direct control of larger loads without external relays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQuestion: Is this module hot-swappable?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAnswer: Yes, the \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003e900H01-0102\u003c\/span\u003e\u003c\/strong\u003e supports hot-swapping in powered racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePurchasing Advice\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAlways confirm your current load stays below 4 Amps.\u003c\/li\u003e\n\u003cli\u003eUse surge suppressors for highly inductive loads.\u003c\/li\u003e\n\u003cli\u003eEnsure the \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003eHC900\u003c\/span\u003e\u003c\/strong\u003e firmware supports the 0102 revision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45013999452342,"sku":"900H01-0102","price":122.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/900H01-0102.jpg?v=1775115186","url":"https:\/\/www.plcsparehub.com\/products\/honeywell-hc900-900h01-0102-digital-output-relay-module-8-channel","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}