{"product_id":"honeywell-3001b0501-sensepoint-xcd-industrial-gas-detection","title":"Honeywell 3001B0501 Sensepoint XCD Industrial Gas Detection","description":"\n\u003ch3\u003e\u003cstrong\u003eHoneywell 3001B0501 Sensepoint XCD Gas Detector – Industrial Gas Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1677cc;\"\u003eHoneywell 3001B0501\u003c\/span\u003e\u003c\/strong\u003e belongs to the \u003cstrong\u003e\u003cspan style=\"color: #1677cc;\"\u003eSensepoint XCD Series\u003c\/span\u003e\u003c\/strong\u003e. It provides continuous gas detection for industrial safety applications.\u003c\/p\u003e\n\n\u003cp\u003eThis detector supports \u003cstrong\u003e4–20 mA analog output\u003c\/strong\u003e and \u003cstrong\u003eRS485 Modbus RTU communication\u003c\/strong\u003e. It connects directly to compatible control and monitoring systems.\u003c\/p\u003e\n\n\u003cp\u003eIts epoxy-painted aluminum alloy housing supports demanding industrial environments. Pole and wall mounting options simplify field installation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e1. Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677cc;\"\u003e3001B0501\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677cc;\"\u003eSensepoint XCD\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial Gas Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage – ATEX\/IECEx\/AP Versions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16–32 VDC, 24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage – UL\/CSA Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12–32 VDC, 24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 W at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, source or sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy-painted aluminum alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePole mounting or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003e2. Measurement and Performance Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe supplied specifications define the electrical and communication characteristics. They do not identify the installed sensor type or gas measurement range.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e Depends on the installed gas sensor and detector configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e Requires confirmation against the applicable sensor datasheet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e Depends on the target gas and sensing element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e Requires verification using the selected sensor specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e Depends on the sensor and configured measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Confirm the permitted operating temperature for the exact detector version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resistance:\u003c\/strong\u003e The epoxy-painted aluminum alloy housing supports industrial field installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Performance:\u003c\/strong\u003e Refer to the applicable certification and installation documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e Do not assume identical measurement performance across different Sensepoint XCD sensor configurations. Confirm the target gas, sensor type, and measuring range before ordering.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e3. Installation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eCorrect positioning improves gas detection coverage and simplifies maintenance access.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Location:\u003c\/strong\u003e Select a wall or pole installation point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Characteristics:\u003c\/strong\u003e Consider gas density, ventilation, and potential leakage locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Access:\u003c\/strong\u003e Keep the sensor assembly accessible for inspection and calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Provide a stable 24 VDC nominal supply within the applicable voltage range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Separate signal wiring from high-voltage and high-current circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Follow Honeywell's grounding and shielding recommendations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Connection:\u003c\/strong\u003e Verify the selected 4–20 mA source or sink configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAlways follow the installation manual for the specific certification and sensor configuration.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e4. Commissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eStructured commissioning helps verify detector operation before process startup.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInspection Stage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Action\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitial Inspection\u003c\/td\u003e\n\u003ctd\u003eCheck the housing, mounting hardware, cable entries, and terminal connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Verification\u003c\/td\u003e\n\u003ctd\u003eMeasure the supply voltage at the detector terminals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eConfirm the 4–20 mA source or sink arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Test\u003c\/td\u003e\n\u003ctd\u003eVerify RS485 wiring and Modbus RTU communication settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003ePerform zero and span calibration using approved procedures and test gas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Test\u003c\/td\u003e\n\u003ctd\u003eApply suitable test gas and verify the complete alarm response.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoutine Maintenance\u003c\/td\u003e\n\u003ctd\u003eInspect sensor condition and repeat calibration at the specified intervals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003ePractical Maintenance Tip:\u003c\/strong\u003e A normal 4–20 mA reading does not prove accurate gas measurement. Perform functional gas testing to verify the sensing element and alarm response.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e5. System Compatibility and Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1677cc;\"\u003e3001B0501 Sensepoint XCD\u003c\/span\u003e\u003c\/strong\u003e supports two common industrial integration methods.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC Systems:\u003c\/strong\u003e Connect through a compatible 4–20 mA analog input channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Systems:\u003c\/strong\u003e Transfer gas concentration signals to compatible distributed control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus Networks:\u003c\/strong\u003e Use RS485 and Modbus RTU for digital communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Safety Systems:\u003c\/strong\u003e Integrate with suitable gas monitoring and alarm architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Infrastructure:\u003c\/strong\u003e Check the applicable voltage range before connecting the detector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eVerify the receiving controller's input configuration, communication settings, and signal requirements. Confirm source or sink compatibility before wiring.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e6. Certifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe supplied product information identifies different voltage requirements for several certification versions.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ IECEx \/ AP Versions:\u003c\/strong\u003e 16–32 VDC input range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL \/ CSA Version:\u003c\/strong\u003e 12–32 VDC input range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eConfirm the exact certification markings on the product nameplate before installation. Do not assume every 3001B0501 configuration carries all listed approvals.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e7. Packaging and Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × Honeywell \u003cstrong\u003e\u003cspan style=\"color: #1677cc;\"\u003e3001B0501 Sensepoint XCD Gas Detector\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProtective packaging for transportation.\u003c\/li\u003e\n\u003cli\u003eProduct identification and model verification before dispatch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupply Condition:\u003c\/strong\u003e New and original product.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, DHL, or UPS international delivery options.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailability:\u003c\/strong\u003e Contact our sales team for current stock and lead-time confirmation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e8. Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: Can the 3001B0501 connect directly to a PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. The detector provides a 4–20 mA output for compatible PLC analog input channels. Check the input type and source or sink configuration before wiring.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What is the difference between 4–20 mA and Modbus RTU integration?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe 4–20 mA output transfers an analog measurement signal. Modbus RTU provides digital communication through RS485. Select the method that matches your control system architecture.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can I replace an existing gas detector with the 3001B0501?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eNot without checking the original detector configuration. Compare the target gas, sensor type, measuring range, mounting arrangement, supply voltage, and output requirements.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Why does a detector show a normal current output but fail a gas test?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eA normal current signal does not guarantee sensor accuracy. Sensor aging, contamination, incorrect calibration, or unsuitable test gas can affect detection performance. Check the sensor and perform an approved calibration and functional test.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What should I confirm before purchasing the 3001B0501?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eConfirm the complete model number, target gas, sensor configuration, certification version, supply voltage, and communication requirements. Also check whether your PLC or DCS requires a sourcing or sinking current input.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e9. Ordering Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eTo avoid configuration mismatches, provide the following information when requesting a quotation:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Model:\u003c\/strong\u003e Honeywell 3001B0501.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Gas:\u003c\/strong\u003e Specify the gas requiring detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e ATEX, IECEx, AP, UL, or CSA requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Confirm the available DC voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Interface:\u003c\/strong\u003e 4–20 mA or RS485 Modbus RTU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Wall-mounted or pole-mounted arrangement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eContact us for a quotation, product availability, and technical assistance. Our team can help verify the model against your existing gas detection system.\u003c\/p\u003e\n","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68045556777142,"sku":"3001B0501","price":147.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/3001B0501-3.jpg?v=1794452476","url":"https:\/\/www.plcsparehub.com\/products\/honeywell-3001b0501-sensepoint-xcd-industrial-gas-detection","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}