{"product_id":"honeywell-2mlr-ac23-power-supply-module-masterlogic-200","title":"Honeywell 2MLR-AC23 Power Supply Module | MasterLogic 200","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1673b1;\"\u003eHoneywell 2MLR-AC23\u003c\/span\u003e\u003c\/strong\u003e is a power supply module designed for industrial PLC control systems. It accepts a nominal \u003cstrong\u003e220VAC input\u003c\/strong\u003e and provides a regulated \u003cstrong\u003e5VDC output\u003c\/strong\u003e. Its rated output current reaches \u003cstrong\u003e7.5A\u003c\/strong\u003e, with a maximum output power of \u003cstrong\u003e37.5W at 55°C\u003c\/strong\u003e. The module supports stable DC power distribution for compatible control hardware. It also provides a dedicated \u003cstrong\u003eRUN status contact\u003c\/strong\u003e for external monitoring. Key features include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input:\u003c\/strong\u003e 220VAC nominal voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Output:\u003c\/strong\u003e 5VDC regulated voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Output Current:\u003c\/strong\u003e 7.5A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Power:\u003c\/strong\u003e 37.5W at 55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Monitoring:\u003c\/strong\u003e LED indication for normal output voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRUN Contact:\u003c\/strong\u003e External operating status monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Built-in input fuses and output overcurrent protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Identification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1673b1;\"\u003e2MLR-AC23\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLC Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Input \/ DC Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e176–264VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e176VA \/ 72W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A peak or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65% or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot specified in the supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstantaneous Interruption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin 20ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.5W at 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.0–17.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProtection and Monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250V \/ 3.15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Input Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125V \/ 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTime-lag type, UL approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Replacement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in, not user-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Status Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eON when output voltage is normal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRUN Contact Purpose\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal RUN status monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRUN Contact Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Switching Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Switching Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Switching Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5VDC, 1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOFF-to-ON Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eON-to-OFF Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 million operations or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 operations or more at rated switching current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical and Wiring Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 × 95 × 110mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e384g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Cable Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75–2mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable Crimp Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAV1.25-3.5, RAV2-3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProper installation helps maintain stable power delivery and reliable PLC operation. \u003cstrong\u003e1. Mounting Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the installation position before mounting.\u003c\/li\u003e\n\u003cli\u003eConfirm sufficient cabinet clearance.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the module.\u003c\/li\u003e\n\u003cli\u003eSecure the module according to system instructions.\u003c\/li\u003e\n\u003cli\u003eAvoid locations with excessive vibration or moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. AC Input Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the supply voltage before connection.\u003c\/li\u003e\n\u003cli\u003eKeep the input voltage within 176–264VAC.\u003c\/li\u003e\n\u003cli\u003eUse cables within the specified 0.75–2mm² range.\u003c\/li\u003e\n\u003cli\u003eSelect suitable crimp terminals for the cable size.\u003c\/li\u003e\n\u003cli\u003eCheck terminal tightness before energizing the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. DC Output Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify output polarity before connecting the load.\u003c\/li\u003e\n\u003cli\u003eConfirm that connected equipment requires 5VDC.\u003c\/li\u003e\n\u003cli\u003eKeep the total load within the 7.5A rating.\u003c\/li\u003e\n\u003cli\u003eCheck terminal connections for loose contacts.\u003c\/li\u003e\n\u003cli\u003ePrevent short circuits during installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4. RUN Contact Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse the RUN contact for external status monitoring.\u003c\/li\u003e\n\u003cli\u003eKeep switching voltage within the 24VDC rating.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the 0.5A rated switching current.\u003c\/li\u003e\n\u003cli\u003eCheck external circuit requirements before connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA structured commissioning procedure helps identify wiring and loading problems. \u003cstrong\u003eInitial Commissioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eInspect the housing and terminals for physical damage.\u003c\/li\u003e\n\u003cli\u003eVerify the AC input wiring and supply voltage.\u003c\/li\u003e\n\u003cli\u003eCheck the DC output connections and polarity.\u003c\/li\u003e\n\u003cli\u003eEnergize the module under controlled conditions.\u003c\/li\u003e\n\u003cli\u003eConfirm that the voltage status LED turns ON.\u003c\/li\u003e\n\u003cli\u003eMeasure the output voltage with a calibrated multimeter.\u003c\/li\u003e\n\u003cli\u003eVerify the RUN contact response through the external circuit.\u003c\/li\u003e\n\u003cli\u003eApply the operating load and check output stability.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eRoutine Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect terminal connections during scheduled maintenance.\u003c\/li\u003e\n\u003cli\u003eCheck output voltage under normal operating loads.\u003c\/li\u003e\n\u003cli\u003eMonitor abnormal temperature increases.\u003c\/li\u003e\n\u003cli\u003eInvestigate unexpected PLC power interruptions.\u003c\/li\u003e\n\u003cli\u003eInspect the RUN monitoring circuit when signals become unreliable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eField Troubleshooting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED OFF:\u003c\/strong\u003e Check AC input voltage, wiring, and internal protection status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow DC Output:\u003c\/strong\u003e Measure output voltage under load and inspect connected circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeated Power Loss:\u003c\/strong\u003e Check input voltage fluctuations and load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRUN Signal Abnormal:\u003c\/strong\u003e Test external wiring and contact switching circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Overload:\u003c\/strong\u003e Disconnect unnecessary loads and verify total current demand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe internal fuse is not user-replaceable. Follow approved Honeywell service procedures when internal protection operates.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Selection Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1673b1;\"\u003eHoneywell 2MLR-AC23\u003c\/span\u003e\u003c\/strong\u003e supplies 5VDC power for compatible control system hardware. Check the following conditions before ordering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Compatibility:\u003c\/strong\u003e Connected equipment must accept a 5VDC supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Capacity:\u003c\/strong\u003e Total load must remain within 7.5A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Budget:\u003c\/strong\u003e Connected loads must respect the 37.5W rating at 55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e The cabinet supply must support 176–264VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRUN Monitoring:\u003c\/strong\u003e External circuits must support the specified contact ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Compatibility:\u003c\/strong\u003e Verify dimensions and mounting arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Confirm the module position and configuration against Honeywell hardware documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not select a replacement based only on matching voltage and dimensions. Check connector assignments, mounting requirements, and system power architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied specifications identify the following fuse characteristics:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Fuse:\u003c\/strong\u003e 250V \/ 3.15A, time-lag type, UL approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Fuse:\u003c\/strong\u003e 125V \/ 10A, time-lag type, UL approved.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese approvals apply to the specified fuse components. They do not independently establish complete module certification. Confirm the applicable module certification documents before project approval.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eStandard product package:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color: #1673b1;\"\u003eHoneywell 2MLR-AC23\u003c\/span\u003e Power Supply Module\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMounting accessories, cables, and additional documentation depend on the confirmed order configuration. Please verify package contents before purchase.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the rated output of the Honeywell 2MLR-AC23?\u003c\/strong\u003e The module provides 5VDC output with a rated current of 7.5A. Its rated output power reaches 37.5W at 55°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the 2MLR-AC23 operate with a 200VAC input?\u003c\/strong\u003e Yes. Its specified input range covers 176–264VAC. A 200VAC supply falls within this range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should engineers check when the output voltage LED remains OFF?\u003c\/strong\u003e First, measure the AC input voltage. Then inspect the input wiring and connected load. Check for short circuits or abnormal loading. The internal fuse is not user-replaceable. Follow the approved service procedure if protection operates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can the RUN contact directly drive a large external relay or contactor?\u003c\/strong\u003e Not necessarily. The RUN contact supports 24VDC and 0.5A maximum switching ratings. Check the external device's coil current and switching characteristics. Use an appropriately rated interface relay when the load exceeds these limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How should engineers select a replacement for the 2MLR-AC23?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart by checking the original module model and system configuration. Then verify the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAC input voltage range.\u003c\/li\u003e\n\u003cli\u003e5VDC output requirement.\u003c\/li\u003e\n\u003cli\u003eMinimum 7.5A rated current requirement.\u003c\/li\u003e\n\u003cli\u003eOutput power and loading conditions.\u003c\/li\u003e\n\u003cli\u003eRUN contact specifications.\u003c\/li\u003e\n\u003cli\u003eMechanical dimensions and terminal assignments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA replacement must satisfy both electrical and system-level requirements. Do not rely on output voltage alone. \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68034820669622,"sku":"2MLR-AC23","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/2MLR-AC23-1.jpg?v=1794369321","url":"https:\/\/www.plcsparehub.com\/products\/honeywell-2mlr-ac23-power-supply-module-masterlogic-200","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}