{"product_id":"honeywell-2mlr-ac13-masterlogic-power-supply-module-5vdc-8-5a","title":"Honeywell 2MLR-AC13 MasterLogic Power Supply Module 5VDC 8.5A","description":"\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eHoneywell 2MLR-AC13\u003c\/span\u003e\u003c\/strong\u003e is an AC-powered supply module for the \u003cstrong\u003eHoneywell MasterLogic control system\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eIt converts 110 VAC input power into a regulated \u003cstrong\u003e5 VDC output\u003c\/strong\u003e. The module supplies up to \u003cstrong\u003e8.5 A\u003c\/strong\u003e for compatible control system components.\u003c\/p\u003e\n\n\u003cp\u003eIts integrated protection functions help maintain stable power distribution. Built-in fuse protection addresses input-side electrical faults. Overcurrent protection helps protect the output circuit.\u003c\/p\u003e\n\n\u003cp\u003eThe module also provides a \u003cstrong\u003eRUN contact\u003c\/strong\u003e for external status monitoring. A front-panel LED indicates normal output voltage conditions.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e2MLR-AC13\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMasterLogic Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAC Input Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e110 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85–132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Power\u003c\/td\u003e\n\u003ctd\u003e176 VA \/ 72 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e20 A peak or lower, within 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Efficiency\u003c\/td\u003e\n\u003ctd\u003e65% or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC ±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e8.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e46.75 W at 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercurrent Protection\u003c\/td\u003e\n\u003ctd\u003e9.3–17.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstantaneous Interruption Tolerance\u003c\/td\u003e\n\u003ctd\u003eWithin 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Status Indicator\u003c\/td\u003e\n\u003ctd\u003eLED illuminates under normal output voltage conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRUN Contact Purpose\u003c\/td\u003e\n\u003ctd\u003eExternal operating status indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Contact Switching Capacity\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Switching Load\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Response Time\u003c\/td\u003e\n\u003ctd\u003eOFF to ON: ≤10 ms; ON to OFF: ≤12 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Contact Life\u003c\/td\u003e\n\u003ctd\u003e20 million operations or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Contact Life\u003c\/td\u003e\n\u003ctd\u003e100,000 operations or more at rated switching current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Cable Size\u003c\/td\u003e\n\u003ctd\u003e0.75–2 mm (as specified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Crimp Terminals\u003c\/td\u003e\n\u003ctd\u003eRAV1.25-3.5, RAV2-3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e55 × 95 × 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e334 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePower Conversion and Protection Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Stage:\u003c\/strong\u003e Accepts 85–132 VAC input across 47–63 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Output Stage:\u003c\/strong\u003e Provides regulated 5 VDC power with ±2% voltage tolerance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Capacity:\u003c\/strong\u003e Delivers 8.5 A and 46.75 W at 55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e Provides protection within the specified 9.3–17.0 A range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Fuse:\u003c\/strong\u003e Uses an integrated, non-user-replaceable fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRUN Contact:\u003c\/strong\u003e Supports external monitoring of the module's operating status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Indicator:\u003c\/strong\u003e Displays normal output voltage through the front-panel LED.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eIntegrated Fuse Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eAC input: 250 V \/ 3.15 A, UL-approved time-lag type.\u003c\/li\u003e\n\u003cli\u003eDC input: 125 V \/ 10 A, UL-approved time-lag type.\u003c\/li\u003e\n\u003cli\u003eBoth fuses are built into the module and are not user-replaceable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the Model:\u003c\/strong\u003e Confirm the module designation as 2MLR-AC13 before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Input Power:\u003c\/strong\u003e Verify 110 VAC nominal input and the permitted 85–132 VAC range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Wiring:\u003c\/strong\u003e Use cables within the specified 0.75–2 mm range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect Terminals:\u003c\/strong\u003e Use compatible RAV1.25-3.5 or RAV2-3.5 crimp terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Connections:\u003c\/strong\u003e Verify input polarity requirements and terminal assignments against the manufacturer's wiring documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure Installation:\u003c\/strong\u003e Mount the module in its designated system position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Clearance:\u003c\/strong\u003e Maintain sufficient space for ventilation and electrical maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApply Power:\u003c\/strong\u003e Energize the module after completing wiring and safety inspections.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Disconnect the power source before installation or wiring changes. Follow the original equipment manufacturer's grounding and electrical safety requirements.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eCheck the module's input and output conditions during initial commissioning. Use the following inspection points:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e Confirm the supply remains within 85–132 VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e Verify the 5 VDC output within its ±2% tolerance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Loading:\u003c\/strong\u003e Keep the operating current within the 8.5 A rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Status:\u003c\/strong\u003e Confirm the voltage indicator illuminates under normal conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRUN Contact:\u003c\/strong\u003e Check contact switching through the connected monitoring circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Condition:\u003c\/strong\u003e Inspect wiring tightness and signs of overheating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Keep surrounding airflow paths free from obstructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe integrated fuse is not user-replaceable. Replace the complete module if internal fuse failure occurs.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003e2MLR-AC13\u003c\/strong\u003e belongs to the Honeywell MasterLogic product family.\u003c\/li\u003e\n\u003cli\u003eIts 5 VDC output supports compatible system power requirements.\u003c\/li\u003e\n\u003cli\u003eVerify the rack, base, and controller power specifications before installation.\u003c\/li\u003e\n\u003cli\u003eCheck the system's total power consumption against the module's output capacity.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal assignments and mechanical mounting compatibility with the original system documentation.\u003c\/li\u003e\n\u003cli\u003eDo not assume compatibility with other MasterLogic power supply models based on appearance alone.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e The supplied specifications do not identify a complete list of compatible controller models or rack configurations. Confirm the exact hardware combination before replacement or system expansion.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCertification and Compliance Information\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Approval:\u003c\/strong\u003e The specified AC and DC time-lag fuses carry UL approval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Certification:\u003c\/strong\u003e No complete module-level certification list was provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Compliance:\u003c\/strong\u003e Follow applicable industrial electrical installation standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Consult the original manufacturer documentation for certification and regulatory details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e1 × Honeywell \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e2MLR-AC13\u003c\/span\u003e\u003c\/strong\u003e Power Supply Module\u003c\/li\u003e\n\u003cli\u003eProtective packaging for transportation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAdditional accessories, cables, and terminal connectors require separate confirmation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main function of the Honeywell 2MLR-AC13?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe module converts AC input power into regulated 5 VDC power. It supplies compatible MasterLogic system components with up to 8.5 A.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can the 2MLR-AC13 operate with a 120 VAC power source?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. Its specified input range covers 85–132 VAC. A 120 VAC source falls within this range.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What should engineers check when the output voltage LED does not illuminate?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFirst, measure the AC input voltage and inspect the input wiring. Then check the connected load and output terminals. An internal fuse or power circuit fault may require module replacement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: How should engineers evaluate the 8.5 A output capacity?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCalculate the combined current demand of all connected loads. Keep the total within 8.5 A. Also consider the specified 46.75 W output rating at 55°C.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What information should buyers confirm before ordering a replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eConfirm the complete 2MLR-AC13 model number, input voltage, output rating, mounting arrangement, and terminal configuration. Compare the existing module's specifications with the replacement requirements. This reduces commissioning delays and avoids power supply mismatches.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eOrdering and Technical Support\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eWe supply Honeywell industrial automation components for control system maintenance and spare parts planning.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 2MLR-AC13\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e MasterLogic AC Power Supply Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 5 VDC, 8.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, DHL, UPS, and other available international services.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eContact our team for pricing, stock confirmation, delivery arrangements, and technical assistance. Please provide your system model and application requirements when requesting a quotation.\u003c\/p\u003e\n","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68034818048182,"sku":"2MLR-AC13","price":201.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/2MLR-AC13-1.jpg?v=1794369029","url":"https:\/\/www.plcsparehub.com\/products\/honeywell-2mlr-ac13-masterlogic-power-supply-module-5vdc-8-5a","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}