{"product_id":"hidmux2700-pepperl-fuchs-32-channel-hart-multiplexer-primary-module","title":"HiDMux2700 Pepperl+Fuchs 32-Channel HART Multiplexer Primary Module","description":"\u003ch2\u003ePepperl+Fuchs HiDMux2700 Engineering Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003ePepperl+Fuchs HiDMux2700\u003c\/strong\u003e functions as a high-density, 32-channel HART Multiplexer Primary Module engineered for continuous digital field device integration within H-System termination boards. Designed for non-intrinsically safe process loops, this primary module bridges analog 4–20 mA field instrumentation with asset management systems over a multi-drop RS-485 network. By consolidating up to 31 daisy-chained units on a single serial bus, control engineers can poll and configure up to 992 HART field transmitters (revisions 5 through 7) without interrupting critical process control signals.\u003c\/p\u003e\n\u003ch3\u003eSystem Architecture \u0026amp; Signal Integrity Highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Loop Polling:\u003c\/strong\u003e Scans 32 individual HART channels per module with capacitive coupling (≤ 100 Ω output resistance) to ensure zero interference with standard 4–20 mA analog control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Drop Bus Scalability:\u003c\/strong\u003e Addresses 1 to 31 via side-mounted DIP switches, expanding single-port RS-485 host interfaces to manage nearly 1,000 smart field instruments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust 3-Port Galvanic Isolation:\u003c\/strong\u003e Separates RS-485 interface, 24 V DC power supply, and field channels up to 1000 V\u003csub\u003eeff\u003c\/sub\u003e, reinforced by dual-capacitor isolation on every individual HART input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety \u0026amp; Hazardous Location Compliance:\u003c\/strong\u003e Rated up to SIL 3 per IEC\/EN 61508 and certified for Zone 2 \/ Division 2 installation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Loop Diagnostics:\u003c\/strong\u003e Front-panel LEDs provide immediate visual verification of power status (Green PWR ON), active bus traffic (Yellow HART TX), and field wiring anomalies (Red FAULT).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eComprehensive Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter Category\u003c\/th\u003e\n\u003cth\u003eTechnical Specification\u003c\/th\u003e\n\u003cth\u003eEngineering Value \/ Standard\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHART Field Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported Revisions \u0026amp; Channels\u003c\/td\u003e\n\u003ctd\u003eHART Rev. 5 to 7; 32 non-IS channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Voltage \u0026amp; Carrier Detect\u003c\/td\u003e\n\u003ctd\u003e0.12 to 1.5 V\u003csub\u003epp\u003c\/sub\u003e; Active \u0026gt; 0.12 V\u003csub\u003epp\u003c\/sub\u003e \/ Inactive \u0026lt; 0.08 V\u003csub\u003epp\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Impedance \u0026amp; External Terminator\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 5 kΩ input; 230 to 500 Ω standard (up to 1000 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmit Amplitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Dependent Output\u003c\/td\u003e\n\u003ctd\u003e0.43–0.49 V\u003csub\u003epp\u003c\/sub\u003e (200 Ω load); 1.1–1.2 V\u003csub\u003epp\u003c\/sub\u003e (500 Ω load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransient Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDifferential \u0026amp; Common Mode Clamping\u003c\/td\u003e\n\u003ctd\u003e±5.2 V differential; ±10 V common mode (30 V max CMV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRS-485 Host Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBaud Rate \u0026amp; Addressing\u003c\/td\u003e\n\u003ctd\u003e9600, 19200, or 38400 bit\/s (up to 57.6 kbaud); DIP 1–31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDielectric Withstand\u003c\/td\u003e\n\u003ctd\u003e500 V\u003csub\u003erms\u003c\/sub\u003e (Bus\/Power); 1000 V\u003csub\u003eeff\u003c\/sub\u003e (Bus\/Field \u0026amp; Power\/Field)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated Voltage \u0026amp; Dissipation\u003c\/td\u003e\n\u003ctd\u003e20.4 to 30 V DC (24 V DC nominal); ~0.7 W dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temp \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 °C (-4 to 140 °F); 5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHousing Size, Weight \u0026amp; Ingress\u003c\/td\u003e\n\u003ctd\u003e18 × 114 × 130 mm (W × H × D); ~140 g; IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEMC \u0026amp; Functional Safety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61508 (SIL 3); EN 61326-1:2013; NE 21:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eField Engineering \u0026amp; Commissioning FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why does the red FAULT LED illuminate during commissioning even when the 4–20 mA analog loop reads accurately at the DCS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: A solid or flashing red FAULT indicator typically points to an open loop circuit, excessive line capacitance, or a missing\/improperly sized loop resistor. While the analog current may still flow, the HART FSK signal requires a minimum loop resistance of 230 Ω to develop sufficient voltage swing (\u0026gt; 0.12 V\u003csub\u003epp\u003c\/sub\u003e) for carrier detection. Verify that the termination board resistor falls within the 230–500 Ω window and check for loose shield drains.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How do we prevent communication collisions when daisy-chaining multiple multiplexers on a single RS-485 trunk?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Before snapping the housing onto the H-System termination board, set a unique binary address (1 through 31) on the side-mounted DIP switches for every unit on the bus. Ensure all dip-switch baud rates match the host OPC server or asset management gateway, and install a 120 Ω line termination resistor across the differential RS-485 pair at the physical end of the trunk to suppress signal reflections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this module be deployed directly inside Zone 1 hazardous areas to monitor intrinsically safe transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No. This unit is engineered specifically for non-intrinsically safe field loops and carries Zone 2 \/ Division 2 approval. If your field transmitters reside in Zone 0 or Zone 1, you must route those signals through appropriate intrinsically safe isolated barriers first, or utilize an IS-rated multiplexer variant designed for direct hazardous-area loop connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the practical function of the DIP-switch test mode during cabinet factory acceptance testing (FAT)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Engaging the side DIP-switch test mode forces the internal multiplexer circuitry into a self-diagnostic state, allowing commissioning engineers to verify RS-485 host polling, backplane power rail continuity, and LED status transitions without requiring live 4–20 mA transmitters wired to all 32 field terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How does the dual-capacitor channel isolation protect our host workstation during ground potential shifts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Because each of the 32 channels utilizes dedicated dual-capacitor DC isolation alongside 1000 V\u003csub\u003eeff\u003c\/sub\u003e port-to-port isolation, ground loops between separate field junction boxes are completely blocked. Even if a field transmitter experiences a common-mode voltage shift up to 30 V or transient surges up to ±10 V, the clamping circuitry prevents fault currents from propagating back into the RS-485 interface.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/HIDMUX_2700.png?v=1794901587\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":68083458638006,"sku":"HiDMux2700","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/HIDMUX2700-1.jpg?v=1794901574","url":"https:\/\/www.plcsparehub.com\/products\/hidmux2700-pepperl-fuchs-32-channel-hart-multiplexer-primary-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}