{"product_id":"hd2-fbps-1-500-pepperl-fuchs-fieldconnex-power-supply","title":"HD2-FBPS-1.500 Pepperl+Fuchs FieldConnex Power Supply","description":"\u003ch3\u003e\u003cstrong\u003eHD2-FBPS-1.500 | Pepperl+Fuchs High-Power Fieldbus Power Supply Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eHD2-FBPS-1.500\u003c\/span\u003e\u003c\/strong\u003e from \u003cstrong\u003ePepperl+Fuchs\u003c\/strong\u003e is a motherboard-based fieldbus power supply module. It provides a high-power trunk for FOUNDATION Fieldbus H1 and PROFIBUS PA segments.\u003c\/p\u003e\n\u003cp\u003eThe module delivers a nominal output of 28–30 V DC with a rated current of up to 500 mA. Its galvanic isolation separates the fieldbus segment from the supply circuit through functional insulation rated at 250 V AC.\u003c\/p\u003e\n\u003cp\u003eDesigned for high device counts and long cable runs, the \u003cstrong\u003eHD2-FBPS-1.500\u003c\/strong\u003e supports redundant configurations and hot swapping. Maintenance personnel can exchange the module without tools while the system operates, subject to the approved redundant system design.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Fieldbus Power Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supplies operating power to a fieldbus segment through a motherboard-based installation. Its high-power trunk design supports applications that require more field devices or longer cable lengths.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign Element\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eEngineering Significance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule architecture\u003c\/td\u003e\n\u003ctd\u003eMotherboard-based\u003c\/td\u003e\n\u003ctd\u003eUses a compatible motherboard for electrical and mechanical connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus output\u003c\/td\u003e\n\u003ctd\u003e28–30 V DC\u003c\/td\u003e\n\u003ctd\u003eProvides power to the connected fieldbus segment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current\u003c\/td\u003e\n\u003ctd\u003eUp to 500 mA\u003c\/td\u003e\n\u003ctd\u003eDefines the available segment power capacity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e550 mA\u003c\/td\u003e\n\u003ctd\u003eSpecified short-circuit current characteristic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic isolation\u003c\/td\u003e\n\u003ctd\u003eFunctional insulation, 250 V AC\u003c\/td\u003e\n\u003ctd\u003eSeparates the fieldbus segment from the supply circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported fieldbus systems\u003c\/td\u003e\n\u003ctd\u003eFOUNDATION Fieldbus H1 and PROFIBUS PA\u003c\/td\u003e\n\u003ctd\u003eSupports the two specified process fieldbus technologies.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eApplication focus:\u003c\/strong\u003e Use this module where segment power capacity, cable distance, and field-device quantity influence the fieldbus power design. Calculate the complete segment load before selecting the power supply arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Electrical Operating Window\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe input supply accepts a wide DC voltage range. The module converts this supply into the specified fieldbus output voltage and current.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical Parameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated supply voltage (Ur)\u003c\/td\u003e\n\u003ctd\u003e19.2–35 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated supply current (Ir)\u003c\/td\u003e\n\u003ctd\u003e910–490 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical power dissipation\u003c\/td\u003e\n\u003ctd\u003e1.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage (UN)\u003c\/td\u003e\n\u003ctd\u003e28–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current (IN)\u003c\/td\u003e\n\u003ctd\u003e500–10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e550 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output voltage for hazardous-area application (Uo)\u003c\/td\u003e\n\u003ctd\u003e32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDesign note:\u003c\/strong\u003e The specified 500 mA represents the maximum rated output current, not a guaranteed current for every installation condition. Check the actual segment load, cable resistance, device consumption, and voltage drop at the farthest field device.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Redundancy and Online Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe HD2-FBPS-1.500 supports hot swapping in a redundant configuration. This feature helps maintenance teams replace a module without interrupting normal system operation when the complete installation supports the required redundancy.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant operation:\u003c\/strong\u003e Supports integration into a redundant power supply arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-swap capability:\u003c\/strong\u003e Allows module exchange during operation in a suitable redundant configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTool-free replacement:\u003c\/strong\u003e The module can be exchanged without tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance planning:\u003c\/strong\u003e Confirm the active and standby module states before replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHot swapping does not mean that every single-module installation can tolerate removal without interruption. Verify the motherboard arrangement, redundancy configuration, and system maintenance procedure before removing a module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | LED Diagnostics and Fault Interpretation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTwo front-panel indicators provide basic information about output power and fault conditions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eIndicator\u003c\/th\u003e\n\u003cth\u003eState\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003cth\u003eRecommended Check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePWR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003ctd\u003eOutput voltage is above 28 V.\u003c\/td\u003e\n\u003ctd\u003eConfirm the fieldbus segment receives the expected voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eERR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed flashing\u003c\/td\u003e\n\u003ctd\u003eOutput short circuit or undervoltage.\u003c\/td\u003e\n\u003ctd\u003eInspect segment wiring, connected devices, and supply conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eField troubleshooting sequence:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eCheck the PWR LED and determine whether the output exceeds the 28 V indication threshold.\u003c\/li\u003e\n\u003cli\u003eCheck whether ERR flashes, indicating a short-circuit or undervoltage condition.\u003c\/li\u003e\n\u003cli\u003eInspect fieldbus trunk and spur wiring for shorts, damaged insulation, or incorrect terminations.\u003c\/li\u003e\n\u003cli\u003eReview the total current demand of connected field devices.\u003c\/li\u003e\n\u003cli\u003eMeasure voltage at the segment distribution point and at representative remote devices.\u003c\/li\u003e\n\u003cli\u003eCheck the upstream DC supply against the 19.2–35 V DC input range.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eA flashing ERR LED does not identify the exact fault location. Use segment measurements and wiring checks to distinguish a short circuit from an overloaded or undervoltage condition.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Mechanical Design and Installation Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module uses a compact polycarbonate housing and a motherboard-specific connection arrangement. Confirm the motherboard type before installation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting method\u003c\/td\u003e\n\u003ctd\u003eMotherboard mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection type\u003c\/td\u003e\n\u003ctd\u003eMotherboard-specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore cross section\u003c\/td\u003e\n\u003ctd\u003eMotherboard-specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e106 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e128 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation considerations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse the motherboard specified for the module and system architecture.\u003c\/li\u003e\n\u003cli\u003eCheck the module position and mechanical alignment before insertion.\u003c\/li\u003e\n\u003cli\u003eKeep the installation area clean and free from conductive debris.\u003c\/li\u003e\n\u003cli\u003eObserve the IP20 limitation when selecting the cabinet or enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient cabinet space for wiring access and heat dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Environmental Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified environmental limits support installation in demanding industrial control cabinets.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironmental Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003eLess than 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock resistance\u003c\/td\u003e\n\u003ctd\u003e15 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration resistance\u003c\/td\u003e\n\u003ctd\u003e1 g, 10–150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution degree\u003c\/td\u003e\n\u003ctd\u003eMaximum 2, according to IEC 60664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion resistance\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985, severity level G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor corrosive industrial environments, consider the cabinet atmosphere and the actual installation location. The G3 classification provides an environmental reference, but it does not eliminate the need for suitable enclosure and corrosion-control measures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Standards and Hazardous-Area Approvals\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied technical information lists the following standards and approvals.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC directive\u003c\/td\u003e\n\u003ctd\u003e2014\/30\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC standard\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1:2013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC recommendation\u003c\/td\u003e\n\u003ctd\u003eNE 21:2011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61158-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock testing\u003c\/td\u003e\n\u003ctd\u003eEN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration testing\u003c\/td\u003e\n\u003ctd\u003eEN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous-area certification details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApproval System\u003c\/th\u003e\n\u003cth\u003eCertificate\u003c\/th\u003e\n\u003cth\u003eMarking\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX\u003c\/td\u003e\n\u003ctd\u003eTÜV 04 ATEX 2500 X\u003c\/td\u003e\n\u003ctd\u003eII 3 G Ex nA IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM\u003c\/td\u003e\n\u003ctd\u003eFM 19 US 0015 X and FM 19 CA 0011 X\u003c\/td\u003e\n\u003ctd\u003eAEx\/Ex ec IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIECEx\u003c\/td\u003e\n\u003ctd\u003eIECEx TUN 13.0038X\u003c\/td\u003e\n\u003ctd\u003eEx nA IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation in classified areas:\u003c\/strong\u003e The module is specified for Zone 2 and Class I, Division 2 applications. Confirm the certificate conditions, installation instructions, temperature class, and permitted system configuration before use.\u003c\/p\u003e\n\u003cp\u003eThe hazardous-area output parameter Uo is specified as 32 V. Do not use this value alone to determine field-device compatibility. Check the complete certified entity parameters and system documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Field Engineering: Segment Design and Selection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting a fieldbus power supply, engineers should evaluate the complete segment rather than relying only on the maximum output current.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice count:\u003c\/strong\u003e Add the current consumption of every connected field device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable length:\u003c\/strong\u003e Calculate voltage drop across the trunk and spur cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrunk loading:\u003c\/strong\u003e Confirm the current demand remains within the module's rated output capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Check whether the selected motherboard and power architecture support redundant operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous-area design:\u003c\/strong\u003e Verify the required approval and entity parameters for the installed segment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental conditions:\u003c\/strong\u003e Confirm temperature, humidity, corrosion, and cabinet protection requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePractical selection advice:\u003c\/strong\u003e A segment may remain below the 500 mA current limit yet experience low voltage at remote devices. Cable resistance, connector losses, and spur distribution can affect the available voltage. Include these factors in the fieldbus power budget.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I determine whether a fieldbus segment needs a high-power trunk supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the total device current and the longest cable path. Then calculate the voltage available at the most distant device under full load. A high-power supply is useful when device count or cable distance creates a demanding power budget, but the complete segment design must still meet fieldbus voltage requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can this module support both FOUNDATION Fieldbus H1 and PROFIBUS PA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe product information specifies both fieldbus technologies. However, engineers should confirm the host system, motherboard, segment coupler, and configuration support the intended protocol. A compatible power supply does not replace protocol-specific segment components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should be checked when the PWR LED is green but remote devices still lose communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe green PWR indication confirms output voltage above 28 V at the module. It does not prove that every remote device receives sufficient voltage. Measure voltage along the trunk, inspect spur connections, and review device current consumption and cable resistance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does hot swapping guarantee uninterrupted operation during every module replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The hot-swap feature applies to a suitable redundant configuration. Confirm that the redundant partner is operational and that the motherboard and system architecture support online replacement. Follow the approved maintenance procedure before removing the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should buyers provide when sourcing a replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete model number HD2-FBPS-1.500, installed motherboard type, fieldbus protocol, redundancy arrangement, and hazardous-area requirements. If replacing an existing unit, compare the nameplate and certification details. These checks help prevent a mechanically compatible but electrically unsuitable selection.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/HD2-FBPS-1.500.png?v=1795421825\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":68128909131958,"sku":"HD2-FBPS-1.500","price":110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/HD2-FBPS-1.500-3.jpg?v=1795421825","url":"https:\/\/www.plcsparehub.com\/products\/hd2-fbps-1-500-pepperl-fuchs-fieldconnex-power-supply","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}