{"product_id":"ge-mark-vi-series-is200tturh1bcc-turbine-termination-board","title":"GE Mark VI Series IS200TTURH1BCC Turbine Termination Board","description":"\u003ch3\u003eTurbine Control Excellence: IS200TTURH1BCC\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d35400;\"\u003eGeneral Electric\u003c\/span\u003e\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #d35400;\"\u003eIS200TTURH1BCC\u003c\/span\u003e\u003c\/strong\u003e is a critical Primary Protection Input Board designed for the \u003cstrong\u003e\u003cspan style=\"color: #d35400;\"\u003eMark VI\u003c\/span\u003e\u003c\/strong\u003e Speedtronic control series. This module enables essential turbine operations, including precise speed measurement and automatic generator synchronization.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e \u003cspan style=\"color: #d35400;\"\u003eGeneral Electric\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #d35400;\"\u003eIS200TTURH1BCC\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Compatibility:\u003c\/strong\u003e \u003cspan style=\"color: #d35400;\"\u003eMark VI\u003c\/span\u003e Speedtronic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed Sensing:\u003c\/strong\u003e 12 passive pulse rate inputs (2 Hz to 20 kHz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Output:\u003c\/strong\u003e Generator breaker coil (5A at 125 V dc)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Conformal PCB coating; 1,500 V rms magnetic isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d35400;\"\u003eIS200TTURH1BCC\u003c\/span\u003e\u003c\/strong\u003e is the industry standard for power generation protection. Its ability to process signals from potential transformers and shaft voltage sensors provides unmatched operational visibility. For technicians, proper jumper (JP1\/JP2) management is key to successful TMR\/Simplex integration and long-term hardware reliability.\u003c\/p\u003e\n\u003ch3\u003eDiagnostic Capability \u0026amp; Applications\u003c\/h3\u003e\n\u003cp\u003eThis board is essential for high-reliability applications, such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain breaker sequencing and generator synchronization.\u003c\/li\u003e\n\u003cli\u003eMonitoring turbine speed via toothed wheel pulse detection.\u003c\/li\u003e\n\u003cli\u003eAdvanced shaft voltage and current measurement.\u003c\/li\u003e\n\u003cli\u003eRedundant system operations using TMR (Triple Modular Redundancy) architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Warranty\u003c\/h3\u003e\n\u003cp\u003eWe provide a \u003cstrong\u003e12-month quality warranty\u003c\/strong\u003e on every \u003cstrong\u003e\u003cspan style=\"color: #d35400;\"\u003eIS200TTURH1BCC\u003c\/span\u003e\u003c\/strong\u003e unit. Orders are processed for rapid \u003cstrong\u003e24-48 hour dispatch\u003c\/strong\u003e. We support your global operations with reliable shipping via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow should I configure the JP1\/JP2 jumpers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSet these jumpers based on your turbine's architecture—choose Simplex for standard operations or TMR for triple modular redundancy to ensure fault tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the TB3 terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTB3 is specifically designated for TTL connections for active speed pickups, ensuring seamless integration for high-precision turbine speed monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to maintain signal integrity over long distances?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor potential transformer connections extending up to 1,000 feet, always utilize 18 AWG wiring to minimize signal loss and electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelection Guide: Why check the 52G breaker coil rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure your breaker coil operates at the nominal 125 V dc as required by the board’s K25\/K25P\/K25A relay logic to prevent failure during synchronization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is magnetic isolation included on PT inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1,500 V rms barrier protects the control system from high-voltage transients on the generator\/bus lines, significantly improving system reliability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45262688616630,"sku":"IS200TTURH1BCC","price":426.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IS200TTURH1BCC.jpg?v=1784109470","url":"https:\/\/www.plcsparehub.com\/products\/ge-mark-vi-series-is200tturh1bcc-turbine-termination-board","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}