{"product_id":"ge-fanuc-ic697bem733-series-90-70-genius-remote-i-o-scanner-module","title":"GE Fanuc IC697BEM733 Series 90-70 Genius Remote I\/O Scanner Module","description":"\u003ch3\u003eGE Fanuc IC697BEM733 Series 90-70 Genius Remote I\/O Scanner Module\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC697BEM733\u003c\/strong\u003e is an advanced Genius Remote I\/O Scanner module engineered for the \u003cstrong\u003eSeries 90-70\u003c\/strong\u003e Programmable Logic Controller system, originally developed by \u003cstrong\u003eGE Fanuc\u003c\/strong\u003e and currently supported under \u003cstrong\u003eEmerson Automation\u003c\/strong\u003e. This robust communication interface module establishes reliable distributed I\/O architectures across industrial plant floors. It links host controllers with remote drop systems over extended distances up to 7,500 feet (2,275 meters).\u003c\/p\u003e\n\u003cp\u003eEngineered for demanding industrial environments, the \u003cstrong\u003eIC697BEM733\u003c\/strong\u003e supports complex configurations of discrete and analog signals. It features dedicated ports for programming, monitoring, and network expansion, ensuring seamless integration into legacy automation setups while maintaining high diagnostic visibility through onboard status indicators.\u003c\/p\u003e\n\u003ch3\u003eMECE Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003eGE Fanuc\u003c\/strong\u003e \/ Emerson Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-series-90-30-series-90-70\"\u003e\u003cstrong\u003eSeries 90-70\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e \u003cstrong\u003eIC697BEM733\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Description:\u003c\/strong\u003e Genius Remote I\/O Scanner Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Communication and distributed I\/O interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Slot Width:\u003c\/strong\u003e Single slot in an \u003cstrong\u003eIC697\u003c\/strong\u003e PLC rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power Consumption:\u003c\/strong\u003e 800 mA at 5VDC (1.3 Amps backplane current rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 5.0 Volts DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e One 15-pin RS-422\/485 serial port, one 9-pin IC66* handheld monitor port, and dedicated IC66* bus terminals supporting redundancy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Data Rates \u0026amp; Drop Capacities:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e153.6K baud extended: Up to 20 fully-loaded drops, or up to 30 drops if not fully-loaded\u003c\/li\u003e\n\u003cli\u003e76.8K baud: Up to 10 fully-loaded drops, or up to 30 drops if not fully-loaded\u003c\/li\u003e\n\u003cli\u003e38.4K baud: Supports up to 16 devices per bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Capacity:\u003c\/strong\u003e Up to 1024 discrete inputs, 1024 discrete outputs, 64 analog input words, and 64 analog output words\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Bus Length:\u003c\/strong\u003e 7,500 feet (2,275 meters) at 38.4K baud; 3,500 feet (1,060 meters) at 153.6K extended\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination Values:\u003c\/strong\u003e 75, 100, 120, or 150 Ohms at both electrical cable ends\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e Module OK, I\/O Enabled, and Bus Active LED indicators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage Weight:\u003c\/strong\u003e 2.0 Pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Lifecycle Status:\u003c\/strong\u003e Mature industrial automation hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower down the \u003cstrong\u003eSeries 90-70\u003c\/strong\u003e rack before inserting or removing the \u003cstrong\u003eIC697BEM733\u003c\/strong\u003e module.\u003c\/li\u003e\n\u003cli\u003eSlide the module firmly into any available single slot within the main or remote \u003cstrong\u003eIC697\u003c\/strong\u003e PLC rack.\u003c\/li\u003e\n\u003cli\u003eConnect the shielded twisted pair or Twinax bus cable to the appropriate terminal blocks, ensuring proper polarity.\u003c\/li\u003e\n\u003cli\u003eInstall matching 75, 100, 120, or 150-Ohm terminating resistors at both physical ends of the communication bus.\u003c\/li\u003e\n\u003cli\u003eVerify network baud rate jumpers and software configuration settings match connected drop devices.\u003c\/li\u003e\n\u003cli\u003ePower up the system and verify that the Module OK and Bus Active LEDs illuminate steadily.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting Efficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitor the onboard LED status lights for immediate fault identification during runtime operations.\u003c\/li\u003e\n\u003cli\u003eUtilize an IC66* handheld monitor connected directly to the 9-pin front port to isolate communication drop errors.\u003c\/li\u003e\n\u003cli\u003eInspect serial connections and shield grounding periodically to prevent electromagnetic interference in noisy environments.\u003c\/li\u003e\n\u003cli\u003eReview PLC diagnostic registers via programming software to track transient bus dropouts or configuration mismatches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; System Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC Platforms:\u003c\/strong\u003e Fully compatible with \u003cstrong\u003eSeries 90-70\u003c\/strong\u003e systems, IC660 programmable logic controllers, and IC655 controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Requirements:\u003c\/strong\u003e Requires MS-DOS programming software release 3.0 or later and CPU firmware release 2.0 or later for \u003cstrong\u003eIC697\u003c\/strong\u003e setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThird-Party Integration:\u003c\/strong\u003e Supports host computers equipped with Personal Computer Interface Module (PCIM) or Q-bus Interface Module (QBIM) cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandheld Devices:\u003c\/strong\u003e Compatible with version 4.0 or later Hand Held Monitors (catalog number IC660HHM501G).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertification, Logistics \u0026amp; Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Assurance:\u003c\/strong\u003e Rigorously tested hardware backed by a comprehensive \u003cstrong\u003e12-month\u003c\/strong\u003e replacement warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e Expedited global dispatch via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Window:\u003c\/strong\u003e Guaranteed processing and dispatch within \u003cstrong\u003e24 to 48 hours\u003c\/strong\u003e from order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Packaging:\u003c\/strong\u003e Anti-static bubble wrapping enclosed in heavy-duty industrial cardboard boxes for safe transit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Industrial Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge-scale discrete manufacturing plants requiring distributed control over wide physical areas.\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment facilities utilizing remote pump station telemetry networks.\u003c\/li\u003e\n\u003cli\u003ePower generation plants integrating legacy industrial automation nodes with centralized control rooms.\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems needing high-speed communication across multiple production line drops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/h3\u003e\n\u003cp\u003eIndustrial automation engineers managing legacy \u003cstrong\u003eSeries 90-70\u003c\/strong\u003e architectures frequently encounter communication dropouts caused by improper bus termination or degraded cable shielding. In high-noise environments near heavy variable frequency drives, field technicians should ensure that the bus cable shield is grounded at a single point only.\u003c\/p\u003e\n\u003cp\u003eFor example, a mid-sized automotive stamping facility experienced intermittent bus faults on an \u003cstrong\u003eIC697BEM733\u003c\/strong\u003e network spanning 4,000 feet. Field analysis revealed that technicians had installed mismatched 120-Ohm resistors on a line configured for extended 153.6K baud operations using standard twinax cabling. Replacing the termination blocks with correct 100-Ohm resistors and verifying backplane power distribution immediately stabilized packet transmission and eliminated drop timeout errors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat should I check first if the Bus Active LED remains unlit on the IC697BEM733?\u003c\/h4\u003e\n\u003cp\u003eVerify that both ends of the communication bus feature correct matching terminating resistors and check physical cable continuity.\u003c\/p\u003e\n\u003ch4\u003eCan the IC697BEM733 module be hot-swapped in an active PLC rack?\u003c\/h4\u003e\n\u003cp\u003eNo, you must remove power from the \u003cstrong\u003eIC697\u003c\/strong\u003e rack before inserting or extracting communication modules to prevent backplane damage.\u003c\/p\u003e\n\u003ch4\u003eWhat causes communication lag in extended remote drop configurations?\u003c\/h4\u003e\n\u003cp\u003eExceeding maximum specified cable lengths for specific baud rates or encountering excessive electromagnetic interference along unshielded cable runs.\u003c\/p\u003e\n\u003ch4\u003eHow do I select the correct baud rate for my application setup?\u003c\/h4\u003e\n\u003cp\u003eBalance your physical distance requirements against data throughput needs; use lower baud rates like 38.4K for maximum distances up to 7,500 feet.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014012625078,"sku":"IC697BEM733","price":122.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC697BEM733-3.jpg?v=1788847330","url":"https:\/\/www.plcsparehub.com\/products\/ge-fanuc-ic697bem733-series-90-70-genius-remote-i-o-scanner-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}