{"product_id":"ge-fanuc-ic695pnc001-pacsystems-rx3i-profinet-controller-module","title":"GE Fanuc IC695PNC001 PACSystems RX3i PROFINET Controller Module","description":"\u003ch3\u003e\u003cstrong\u003eEngineering Overview \u0026amp; Network Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695PNC001\u003c\/strong\u003e\u003c\/span\u003e is an advanced PROFINET controller module engineered by \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Intelligent Platforms \/ GE Fanuc\u003c\/strong\u003e\u003c\/span\u003e (now supported by Emerson Automation) for the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003ePACSystems RX3i Series\u003c\/strong\u003e\u003c\/span\u003e. This communication module bridges RX3i control systems to high-speed industrial PROFINET networks, delivering deterministic data exchange, robust ring\/star\/daisy-chain topologies, and time-stamped system diagnostics.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; height: 333.239px;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: rgb(242, 242, 242); height: 39.2045px;\"\u003e\n\u003cth style=\"height: 39.2045px;\"\u003e\u003cstrong\u003ePerformance Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"height: 39.2045px;\"\u003e\u003cstrong\u003eEngineering Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc \/ GE Intelligent Platforms (Emerson)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"height: 39.2045px;\"\u003e\u003cstrong\u003eCatalog \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.2045px;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695PNC001\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003e\u003cstrong\u003eProduct Series \u0026amp; Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003ePACSystems RX3i\u003c\/a\u003e PROFINET Controller\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003e\u003cstrong\u003eChassis Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003eSingle slot, universal backplane support (Main rack only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003e\u003cstrong\u003eCPU Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003eRX3i CPU315 or CPU320 (Firmware version 7.0 or higher)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003ePROFINET Version 2.2 General Class A IO-Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"height: 39.2045px;\"\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.2045px;\"\u003eTwo (2) RJ-45 copper ports, Two (2) SFP cages, One (1) Micro USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003e\u003cstrong\u003eDevice Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003eUp to 64 I\/O devices per controller; 128 devices per network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003e\u003cstrong\u003eData Update Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.6023px;\"\u003eConfigurable from 1 ms up to 512 ms intervals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"height: 39.2045px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.2045px;\"\u003e1.5A @ 5V DC max; 0.5A @ 3.3V DC; up to 1.2A total with dual SFP devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"height: 39.2045px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 39.2045px;\"\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Constraints \u0026amp; Structural Hierarchy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSlot Limitations:\u003c\/strong\u003e\u003c\/span\u003e Maximum of four (4) \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695PNC001\u003c\/strong\u003e\u003c\/span\u003e modules can operate along a single CPU backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eRack Restriction:\u003c\/strong\u003e\u003c\/span\u003e Must be installed exclusively in the main RX3i CPU rack; remote racks are not supported for controller hosting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eHot-Swap Capability:\u003c\/strong\u003e\u003c\/span\u003e Fully supports Removal and Insertion Under Power (RIUP) without disrupting un-associated backplane communications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eMemory Allocation:\u003c\/strong\u003e\u003c\/span\u003e Allocates 128 Kbytes of combined input\/output memory per PROFINET controller instance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRX3i CPU Controllers:\u003c\/strong\u003e Directly pairs with PACSystems CPU315 and CPU320 executing firmware 7.0 or newer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed I\/O Drops:\u003c\/strong\u003e Interfaces with modular VersaMax and RX3i distributed I\/O blocks across PROFINET lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Ethernet Switches:\u003c\/strong\u003e Connects via standard copper RJ-45 or optical fiber SFP transceivers (SFP units sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineering Workstations:\u003c\/strong\u003e Links via Micro USB for command-line interface configuration and diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Control Applications \u0026amp; Diagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695PNC001\u003c\/strong\u003e\u003c\/span\u003e coordinates high-performance automation networks across continuous process and high-speed discrete manufacturing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDistributed Motion \u0026amp; Drive Networks:\u003c\/strong\u003e\u003c\/span\u003e Manages synchronous data exchange with multi-axis servo drives and variable frequency drives over industrial Ethernet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eRedundant Ring Topologies:\u003c\/strong\u003e\u003c\/span\u003e Implements fault-tolerant ring architectures to ensure zero packet loss during media breaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eCommand-Line Interface (CLI) Diagnostics:\u003c\/strong\u003e\u003c\/span\u003e Built-in Telnet and micro-USB toolsets provide direct monitoring, parameter tweaking, and firmware updates via WinLoader.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSynchronized Event Logging:\u003c\/strong\u003e\u003c\/span\u003e Features an internal hardware clock matched to the RX3i CPU for precise time-stamped error logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen deploying the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695PNC001\u003c\/strong\u003e\u003c\/span\u003e in high-density engineering environments, power budgeting requires careful attention. While the base module draws 0.5A at 3.3V DC, inserting two high-performance SFP optical transceivers adds 0.35A per module, pushing total backplane power draw higher. Furthermore, always verify that your RX3i CPU firmware is flashed to version 7.0 or higher before installation to prevent backplane handshaking faults during initial rack power-up.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics, Fulfillment \u0026amp; Quality Guarantee\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition Status:\u003c\/strong\u003e 100% Brand New and Original Factory Sealed Inventory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFulfillment Lead Time:\u003c\/strong\u003e Guaranteed order processing and dispatch within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Express Logistics:\u003c\/strong\u003e Secure worldwide air transit delivered via FedEx, UPS, or DHL with end-to-end tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Assurance:\u003c\/strong\u003e Fully protected by a comprehensive 12-Month Factory Defect Warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why must the IC695PNC001 module be installed exclusively in the main CPU rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module relies on high-speed backplane data exchanges and direct CPU clock synchronization that can only be achieved when placed directly on the main universal backplane alongside the CPU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How do I update the firmware on this PROFINET controller if standard PAC Machine Edition tools fail?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Technicians can utilize the dedicated WinLoader software utility connecting directly through the front panel micro-USB interface or Ethernet network port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What precautions should I take when installing SFP transceivers into the SFP cages?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Ensure you account for the additional 0.35A power draw per SFP device against your rack power supply budget, and always use factory-approved optical transceivers to maintain link integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the purpose of the manual restart pushbutton on the faceplate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The physical restart pushbutton allows field engineers to manually reboot the PROFINET controller processor for troubleshooting without needing to power-cycle the entire RX3i chassis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How should I choose between star, ring, and daisy-chain topologies when planning my network layout?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Choose a ring topology (such as MRP) for high-availability applications requiring redundant path recovery, and use daisy-chaining or star configurations for straightforward linear machine cells or cabinet drops.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014010888374,"sku":"IC695PNC001","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695PNC001.jpg?v=1784620994","url":"https:\/\/www.plcsparehub.com\/products\/ge-fanuc-ic695pnc001-pacsystems-rx3i-profinet-controller-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}