{"product_id":"ge-fanuc-ic693cpu360-25-mhz-series-90-30-processor","title":"GE Fanuc IC693CPU360 25 MHz Series 90-30 Processor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eGE Fanuc IC693CPU360\u003c\/span\u003e\u003c\/strong\u003e is a high-performance CPU module for the \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eSeries 90-30 PLC\u003c\/span\u003e\u003c\/strong\u003e platform. It executes application logic and coordinates industrial control operations across local and remote I\/O systems.\u003c\/p\u003e\n\u003cp\u003ePowered by an \u003cstrong\u003e80386EX microprocessor\u003c\/strong\u003e, this controller operates at \u003cstrong\u003e25 MHz\u003c\/strong\u003e. It delivers a typical Boolean logic scan rate of \u003cstrong\u003e0.22 ms per 1K logic\u003c\/strong\u003e. Its \u003cstrong\u003e240 KB user memory\u003c\/strong\u003e supports application programs and control data.\u003c\/p\u003e\n\u003cp\u003eThe module occupies one slot in a Series 90-30 baseplate. It supports up to eight baseplates, including the local rack and seven additional I\/O baseplates. This architecture provides flexibility for distributed control configurations.\u003c\/p\u003e\n\u003cp\u003eUnlike CPUs with an onboard serial connector, the \u003cstrong\u003eIC693CPU360\u003c\/strong\u003e accesses serial communications through the RS-485 port on the power supply. This arrangement supports programming and controller communication through the power supply interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eIC693CPU360\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries 90-30\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePLC CPU \/ Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e80386EX Microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Clock Speed\u003c\/td\u003e\n\u003ctd\u003e25 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e240 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Scan Rate\u003c\/td\u003e\n\u003ctd\u003e0.22 ms per 1K Boolean logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003eSingle Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n\u003ctd\u003e670 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Communication\u003c\/td\u003e\n\u003ctd\u003eRS-485 via power supply module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated CPU Serial Connector\u003c\/td\u003e\n\u003ctd\u003eNot provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 baseplates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 2,048 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 2,048 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Global Memory\u003c\/td\u003e\n\u003ctd\u003e1,280 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Coils\u003c\/td\u003e\n\u003ctd\u003e4,096\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemporary Outputs\u003c\/td\u003e\n\u003ctd\u003e256 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegister Memory\u003c\/td\u003e\n\u003ctd\u003e9999 words on pre-Release 9 firmware; configurable on later firmware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimers and Counters\u003c\/td\u003e\n\u003ctd\u003eMore than 2,000 supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Storage\u003c\/td\u003e\n\u003ctd\u003eRAM and Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30 PLC baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMemory Architecture and Processing Capacity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eIC693CPU360\u003c\/span\u003e\u003c\/strong\u003e combines program execution, register storage, and discrete data management. Its memory configuration supports different application requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Program Memory:\u003c\/strong\u003e 240 KB for application logic and control instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Inputs:\u003c\/strong\u003e Up to 2,048 input points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Outputs:\u003c\/strong\u003e Up to 2,048 output points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Data:\u003c\/strong\u003e 1,280 discrete global memory points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Coils:\u003c\/strong\u003e 4,096 internal control bits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemporary Outputs:\u003c\/strong\u003e 256 temporary output bits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTimers and Counters:\u003c\/strong\u003e Supports more than 2,000 instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRegister memory requires firmware verification.\u003c\/strong\u003e Firmware before Release 9 provides a fixed 9,999-word configuration. Release 9 and later support configurable register memory.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogicmaster:\u003c\/strong\u003e 128 to 16,384 words in 128-word increments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Version 2.2:\u003c\/strong\u003e 128 to 32,640 words in 128-word increments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and Programming Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC693CPU360\u003c\/strong\u003e uses the RS-485 communication interface located on the power supply module. Technicians can access this connector by opening the power supply swing door.\u003c\/p\u003e\n\u003cp\u003eSupported programming environments include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogicmaster 90:\u003c\/strong\u003e Supports Series 90-30 PLC programming and configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Provides controller programming and register configuration functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersaPro:\u003c\/strong\u003e Supports legacy Series 90-30 application development.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCIMPLICITY Machine Edition:\u003c\/strong\u003e Provides Logic Developer programming capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHand-Held Programmer (HHP):\u003c\/strong\u003e Supports legacy programming and maintenance operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify software versions, firmware compatibility, and communication settings before commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the Rack:\u003c\/strong\u003e Confirm that the baseplate supports the IC693CPU360 processor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the Power Supply:\u003c\/strong\u003e Verify the 5 VDC backplane supply capacity. Allow at least 670 mA for this CPU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Disconnect rack power before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the Slot:\u003c\/strong\u003e Check the backplane connector and module alignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall the CPU:\u003c\/strong\u003e Insert the processor into its designated single-width slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect Communications:\u003c\/strong\u003e Access the RS-485 connector on the power supply module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigure the System:\u003c\/strong\u003e Verify rack assignments, I\/O addresses, and memory settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestore Power:\u003c\/strong\u003e Start the controller and check its diagnostic status.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Follow the applicable GE Fanuc installation manual. Confirm the exact baseplate and power supply configuration before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Verification:\u003c\/strong\u003e Check the 5 VDC backplane supply under normal operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Testing:\u003c\/strong\u003e Verify RS-485 wiring, connector condition, and communication parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgram Validation:\u003c\/strong\u003e Confirm the downloaded application and memory configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan Performance:\u003c\/strong\u003e Monitor scan time during representative machine operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Diagnostics:\u003c\/strong\u003e Compare controller status with field device feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup Management:\u003c\/strong\u003e Maintain verified program copies and configuration records.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Inspection:\u003c\/strong\u003e Keep the rack within its specified operating temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck firmware and programming software compatibility before changing controller configurations. Record all program modifications during maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegration Item\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility Consideration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC Platform\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Series 90-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate\u003c\/td\u003e\n\u003ctd\u003eCompatible Series 90-30 rack configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eMust provide sufficient 5 VDC backplane current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O\u003c\/td\u003e\n\u003ctd\u003eSupports up to seven additional baseplates beyond the local rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Interface\u003c\/td\u003e\n\u003ctd\u003eRS-485 connector on the power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003eLogicmaster 90, Control, VersaPro, Logic Developer, and HHP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Integration\u003c\/td\u003e\n\u003ctd\u003eNo integrated Ethernet port; additional communication hardware may be required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eIntegration Note:\u003c\/strong\u003e The IC693CPU360 does not provide an onboard Ethernet interface. Confirm the required communication architecture before connecting it to supervisory systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification and Environmental Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 5 VDC backplane supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Load:\u003c\/strong\u003e 670 mA typical specified backplane current consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Installation:\u003c\/strong\u003e Use a suitable industrial control cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e Verify applicable approvals against the exact product revision and manufacturer documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSpecific EMC, electrical safety, hazardous-area, and environmental protection ratings require confirmation. Do not assume an IP rating or certification without supporting documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging and Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × GE Fanuc \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eIC693CPU360\u003c\/span\u003e\u003c\/strong\u003e CPU Module\u003c\/li\u003e\n\u003cli\u003eProtective packaging for transportation.\u003c\/li\u003e\n\u003cli\u003eProduct identification and model verification before dispatch.\u003c\/li\u003e\n\u003cli\u003e12-month warranty.\u003c\/li\u003e\n\u003cli\u003eShipping support through DHL, FedEx, or UPS, subject to destination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact our sales team to confirm stock status, product condition, delivery arrangements, and order requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the IC693CPU360 communicate directly through an onboard RS-485 connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This CPU uses the RS-485 connector on the power supply module. Technicians must access the power supply interface for serial communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should engineers check when the IC693CPU360 fails to communicate with programming software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, inspect the power supply communication connector and cable. Then verify serial parameters, software compatibility, and controller operating status. Incorrect communication settings can prevent successful programming access.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How does firmware Release 9 affect register memory configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRelease 9 introduces configurable register memory. Logicmaster supports up to 16,384 words, while Control Version 2.2 supports up to 32,640 words. Earlier firmware uses a fixed 9,999-word configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can the IC693CPU360 control multiple remote I\/O racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The controller supports up to eight baseplates. This includes one local rack and seven additional distributed or remote I\/O baseplates. Engineers must verify the complete rack architecture and communication requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Can the IC693CPU360 connect directly to an Ethernet network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This CPU does not include an integrated Ethernet port. Applications requiring Ethernet communication need compatible external communication hardware or an appropriate system-level interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: What should buyers verify before replacing an existing Series 90-30 CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the complete part number, baseplate configuration, power supply capacity, firmware revision, program memory requirements, and communication interface. Also verify the existing I\/O architecture before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ7: Is the 240 KB user memory the same as register memory?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. User memory and register memory serve different purposes. The 240 KB specification describes user program memory, while register memory stores application data in configurable word locations.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013993717942,"sku":"IC693CPU360","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC693CPU360-1.jpg?v=1795412256","url":"https:\/\/www.plcsparehub.com\/products\/ge-fanuc-ic693cpu360-25-mhz-series-90-30-processor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}