{"product_id":"ge-ds200adgih1aaa-ex2000-auxiliary-dc-generator-control-card","title":"GE DS200ADGIH1AAA EX2000 Auxiliary DC Generator Control Card","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe General Electric \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eDS200ADGIH1AAA\u003c\/strong\u003e\u003c\/span\u003e serves as an auxiliary DC 2000V generator interlock control card. This advanced board integrates into legacy \u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eMark V\u003c\/strong\u003e\u003c\/span\u003e turbine control systems and \u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eEX2000\u003c\/strong\u003e\u003c\/span\u003e excitation environments. It manages critical safety logic for high-voltage direct current auxiliary systems. Engineers rely on this module to orchestrate field flashing execution safely. It monitors breaker status and drives critical system interlocks continuously. The board prevents destructive generator operation by enforcing hardware-level permissive sequences. It secures the turbine-generator unit during startup, synchronization, and emergency shutdown phases.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e General Electric (GE)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eDS200ADGIH1AAA\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Series:\u003c\/strong\u003e \u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eMark V\u003c\/strong\u003e\u003c\/span\u003e \/ \u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eEX2000\u003c\/strong\u003e\u003c\/span\u003e Excitation Control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Auxiliary Interface and Generator Interlock Board\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnalog Output Current:\u003c\/strong\u003e 0-20 mA loop configuration\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Demand:\u003c\/strong\u003e Requires stable +5 V dc logic power\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e Monitored auxiliary voltage levels up to 2000V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e Optimized for rapid sub-millisecond fault detection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHardware Interface:\u003c\/strong\u003e Contains one 40-pin connector and one 6-pin connector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration Jumpers:\u003c\/strong\u003e Includes 60 on-board hardware jumpers for signal routing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e Performance certified from -30 to +65 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhysical Form Factor:\u003c\/strong\u003e Measures 17.8 cm width by 33.02 cm length\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAssembly Classification:\u003c\/strong\u003e Normal assembly utilizing 3 hardware revision layers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility:\u003c\/strong\u003e Enhanced shielding for superior high-voltage noise immunity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Manufactured in the United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Hardware Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eDS200ADGIH1AAA\u003c\/strong\u003e\u003c\/span\u003e interfaces directly with high-voltage excitation cabinets. It connects seamlessly with standard generator control panels. This board supports legacy \u003cspan style=\"color: #0000ff;\"\u003e\u003cstrong\u003eEX2000\u003c\/strong\u003e\u003c\/span\u003e frameworks alongside modern Mark VIe migration architectures. It works efficiently with Basler DECS regulators and Woodward governors. The card bridges the gap between field-level hardware and protection relays. It communicates flawlessly with Allen-Bradley PLCs. It links with breaker management modules like the SEL-751 and GE Multilin SR489. Engineers establish connections via discrete I\/O paths or Modbus\/TCP networks.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostics \u0026amp; Protection Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFast-Acting Trips:\u003c\/strong\u003e Instantly transmits fault signals to the turbine control system during overvoltage events.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHardware Test Points:\u003c\/strong\u003e Features multiple built-in test points for precise voltage and waveform tracking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterlock Logic Enforcement:\u003c\/strong\u003e Blocks crucial operations if field flashing permissives fail to clear.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eANSI Relay Coordination:\u003c\/strong\u003e Integrates seamlessly with ANSI 59, 64, 87G, and 40 protective relays.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReal-Time Monitoring:\u003c\/strong\u003e Supplies accurate 0-20 mA feedback loops to track generator field status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEquipment Suitability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis control card provides optimal performance across specific heavy-duty power generation assets. It integrates perfectly with General Electric frame-size gas turbines. The board functions reliably within large-scale utility steam turbine assemblies. It operates perfectly within static excitation systems that utilize high-capacity thyristor bridges. It supports industrial power distribution setups and synchronization panels. Plant operators install this card within critical turbine supervisory instrument loops.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFrom an engineering perspective, the \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eDS200ADGIH1AAA\u003c\/strong\u003e\u003c\/span\u003e represents robust industrial design. GE built this module to endure severe electrical noise. The 60 onboard hardware jumpers provide versatile loop configuration options. Maintenance teams appreciate the dedicated test points. These test points simplify routine diagnostics during turnarounds. This card remains a vital asset for maintaining uptime. It secures critical infrastructure installations worldwide.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Grounding Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Deployment:\u003c\/strong\u003e Always house the card within shielded excitation or generator control cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection Requirements:\u003c\/strong\u003e Service technicians must wear a grounded wrist strap during hardware handling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatic Dissipation:\u003c\/strong\u003e Touch the protective anti-static bag to a metallic ground structure before unboxing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Secure the card onto the board rack utilizing the four factory-aligned corner screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Segregation:\u003c\/strong\u003e Route high-voltage 2kV cabling away from sensitive low-voltage signaling lines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShield Termination:\u003c\/strong\u003e Ensure all signal shields terminate at a single clean instrumentation ground point.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTroubleshooting \u0026amp; Maintenance Convenience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eDS200ADGIH1AAA\u003c\/strong\u003e\u003c\/span\u003e features hardware-driven test architectures. It simplifies complex troubleshooting tasks significantly. Technicians measure system health directly across isolated trace paths. They utilize calibrated multimeter probes for safe diagnostics. The multi-revision layout ensures straightforward backward compatibility with existing field installations. Maintenance remains safe due to galvanic isolation structures. These structures segment logic circuits from the 2kV bus. Regular inspection schedules require minimal tool kits, shortening plant downtime.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping, Warranty, \u0026amp; Commercial Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e Contains one factory-sealed \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eDS200ADGIH1AAA\u003c\/strong\u003e\u003c\/span\u003e interface board safely packed in ESD wrapping.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Duration:\u003c\/strong\u003e Includes an extensive 12-month comprehensive warranty coverage period.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Methods:\u003c\/strong\u003e Dispatched globally via premium courier services including FedEx, UPS, and DHL.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcessing Speed:\u003c\/strong\u003e Orders qualify for fast 24-48 hour dispatch from our inventory hubs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStock Availability:\u003c\/strong\u003e Maintained in high-priority stock reserves to minimize critical industrial downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the card manage backward compatibility across its hardware revisions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe current \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eDS200ADGIH1AAA\u003c\/strong\u003e\u003c\/span\u003e design supports direct backward compatibility with the first two production revisions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat specific tools are required to test the onboard circuit loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians require a calibrated high-impedance digital multimeter along with properly insulated test probes.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy does this module contain sixty physical jumpers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware jumpers allow manual configuration of signal routing, isolation preferences, and specific logic paths.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow do you prevent static damage if a wrist strap is unavailable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTouch the sealed anti-static bag against a grounded metal desk structure before extracting the circuit card.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat control signals are used to interface with external turbine panels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board utilizes 0-20 mA analog output current loops alongside hardwired discrete relay logic.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProcurement \u0026amp; Selection Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eVerify the full alphanumeric string matching \u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eDS200ADGIH1AAA\u003c\/strong\u003e\u003c\/span\u003e when replacing a card. Check that your cabinet layout aligns with the physical board dimensions. Review your existing jumper settings on the active board prior to removal. Document every jumper position to ensure identical hardware behavior. Always match the logic compatibility levels with your current turbine control baseline version.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45244403318966,"sku":"DS200ADGIH1AAA","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DS200ADGIH1AAA.jpg?v=1783409054","url":"https:\/\/www.plcsparehub.com\/products\/ge-ds200adgih1aaa-ex2000-auxiliary-dc-generator-control-card","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}