{"product_id":"fu20-05-t1-npt-nss-industrial-ph-orp-sensor-yokogawa-fu20-widebody","title":"FU20-05-T1-NPT-NSS Industrial pH\/ORP Sensor Yokogawa FU20 Widebody","description":"\u003ch3\u003e\u003cb\u003eEngineering Overview \u0026amp; Process Value\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eYokogawa FU20-05-T1-NPT-NSS\u003c\/b\u003e\u003c\/font\u003e is an all-in-one, 26 mm wide-body combination sensor designed for continuous liquid analysis in demanding chemical, wastewater, and industrial process loops. Integrating four distinct sensing elements—pH glass electrode, solid platinum ORP electrode, Ag\/AgCl double-junction reference, and an IEC 751 Pt1000 temperature compensator—into a single ruggedized assembly eliminates the need for multiple process penetrations.\u003c\/p\u003e\n\u003cp\u003eConstructed with a chemically resistant 40% glass-filled polyphenylene sulfide (PPS GF40) body and a dome-shaped G-glass membrane, the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eFU20-05-T1-NPT-NSS\u003c\/b\u003e\u003c\/font\u003e delivers rapid dynamic response and high mechanical durability under pressures up to 1000 kPa (10 bar).\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003ePart Number \u0026amp; Configuration Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eVerify the exact suffix architecture of the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eFU20-05-T1-NPT-NSS\u003c\/b\u003e\u003c\/font\u003e against your process piping and transmitter specifications:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eModel \/ Suffix Code\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cb\u003eSpecification Definition\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cb\u003eEngineering Impact\u003c\/b\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cfont color=\"#0056b3\"\u003e\u003cb\u003eFU20\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e\n      \u003ctd\u003eWide Body 4-in-1 Combination Sensor\u003c\/td\u003e\n      \u003ctd\u003e26 mm outer diameter housing combining pH, ORP, reference, and temperature\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003e-05\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e5-Meter Integrated Cable\u003c\/td\u003e\n      \u003ctd\u003eFactory-sealed low-noise coaxial and signal cable for direct transmitter wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003e-T1\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003ePt1000 Temperature Element\u003c\/td\u003e\n      \u003ctd\u003eHigh-accuracy RTD (IEC 751) dedicated to automatic pH temperature compensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003e-NPT\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eTapered Thread \/ Dome Membrane\u003c\/td\u003e\n      \u003ctd\u003ePPS GF40 wetted body rated up to 1000 kPa with low-impedance dome glass (100–300 MΩ)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003e\/NSS\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\" NPT Process Adapter\u003c\/td\u003e\n      \u003ctd\u003eIncludes 1-inch NPT mounting adapter for direct inline tee or tank immersion installation\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eElectrochemical \u0026amp; Physical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eMeasurement Ranges:\u003c\/b\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cb\u003epH Scale:\u003c\/b\u003e 0 to 14 pH (Isothermal point at pH 7 \/ 3.3M KCl)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eORP (Redox) Potential:\u003c\/b\u003e -1500 to +1500 mV\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003erH Value:\u003c\/b\u003e 0 to 100 rH\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eMinimum Process Conductivity:\u003c\/b\u003e \u0026gt; 50 µS\/cm\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eElectrochemical Performance (at 25°C):\u003c\/b\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cb\u003epH Linearity (Slope):\u003c\/b\u003e \u0026gt; 96% of theoretical Nernstian value\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eAsymmetry Potential:\u003c\/b\u003e 8 ± 15 mV\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eDome Glass Impedance:\u003c\/b\u003e 100 to 300 MΩ\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eReference Junction Resistance:\u003c\/b\u003e \u0026lt; 10 kΩ (Non-flow double junction with FDA-approved KCl)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eDynamic Step Response (at 25°C):\u003c\/b\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cb\u003epH Step (7 to 4):\u003c\/b\u003e \u0026lt; 15 seconds for 90% response\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eTemperature Step (10°C):\u003c\/b\u003e \u0026lt; 1 minute for 90% response (Dome shape)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eStabilization Time:\u003c\/b\u003e \u0026lt; 2 minutes (within 0.02 pH unit \/ 10 sec)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eEnvironmental \u0026amp; Wetted Materials:\u003c\/b\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cb\u003eOperating Temperature:\u003c\/b\u003e -10°C to 105°C (14°F to 221°F) for dome-shaped glass\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eOperating Pressure:\u003c\/b\u003e 1.5 kPa to 1000 kPa (10 bar \/ 1 MPa) across 25°C to 105°C\u003c\/li\u003e\n      \u003cli\u003e\n\u003cb\u003eWetted Construction:\u003c\/b\u003e PPS GF40 body, G-glass dome membrane, lead-free glass tube, solid platinum ORP\/earthing pin, porous PTFE reference junction, FKM\/FFKM O-rings\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eAnalyzer Compatibility \u0026amp; Field Deployment\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eSupported Transmitters:\u003c\/b\u003e Engineered for direct integration with \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eYokogawa\u003c\/b\u003e\u003c\/font\u003e 2-wire and 4-wire liquid analyzers, including \u003cb\u003eFLXA202\u003c\/b\u003e, \u003cb\u003eFLXA21\u003c\/b\u003e, \u003cb\u003eFLXA402\u003c\/b\u003e, and \u003cb\u003ePH450G\u003c\/b\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eDifferential Grounding Advantage:\u003c\/b\u003e The solid platinum pin acts simultaneously as the ORP measuring electrode and a solution ground (earthing pin), allowing differential pH measurement that eliminates ground-loop drift and enables advanced sensor diagnostics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eInstallation Notes:\u003c\/b\u003e Mount the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eFU20-05-T1-NPT-NSS\u003c\/b\u003e\u003c\/font\u003e at least 15° above horizontal to keep the internal KCl electrolyte in constant contact with the glass bulb and reference junction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eWarranty \u0026amp; Global Logistics Terms\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eWarranty Coverage:\u003c\/b\u003e Backed by a \u003cb\u003e12-Month Warranty\u003c\/b\u003e covering factory material and workmanship defects from the date of shipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eExpedited Shipping Options:\u003c\/b\u003e Fast international dispatch via \u003cb\u003eFedEx\u003c\/b\u003e, \u003cb\u003eUPS\u003c\/b\u003e, and \u003cb\u003eDHL\u003c\/b\u003e express air freight to minimize plant downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eEngineering Selection \u0026amp; Troubleshooting FAQ\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: Can I use the integrated Pt1000 element to regulate my process heating loop?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The built-in Pt1000 sensor is engineered exclusively for Nernstian pH temperature compensation and transmitter display indication; always use a dedicated process thermowell for closed-loop thermal control.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Why choose the dome-shaped (-NPT) membrane over the flat-surface option?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The dome geometry provides lower glass impedance (100–300 MΩ), faster thermal response (\u0026lt; 1 min vs. \u0026lt; 4 min), and operates down to -10°C, making it ideal for general chemical dosing and cold process lines without heavy abrasive slurries.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: How does the porous PTFE double-junction prevent reference poisoning?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Heavy metals, sulfides, and cyanides typically react with silver ions to clog standard ceramic junctions. The non-flow Ag\/AgCl double junction paired with a hydrophobic porous PTFE diaphragm blocks back-diffusion and resists fouling in dirty industrial effluent.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: What happens if my process water conductivity drops below 50 µS\/cm?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: In ultra-pure water or boiler feedwater below 50 µS\/cm, high solution resistance causes streaming potentials and unstable readings; select a specialized pure-water flowing-reference sensor instead of the standard wide-body model.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: How should I store spare sensors prior to plant turnaround installation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Keep the protective wetting cap filled with 3.3M KCl solution tightly secured over the glass bulb and PTFE junction at all times, and store indoors between 0°C and 40°C to prevent diaphragm dehydration.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68083424592054,"sku":"FU20-05-T1-NPT-NSS","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/FU20-05-T1-NPT-NSS-3.jpg?v=1794895709","url":"https:\/\/www.plcsparehub.com\/products\/fu20-05-t1-npt-nss-industrial-ph-orp-sensor-yokogawa-fu20-widebody","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}