{"product_id":"fsl100-uvir-honeywell-fsl100-flame-detector-uvir-fire-safety-sensor","title":"FSL100-UVIR Honeywell FSL100 Flame Detector UVIR Fire Safety Sensor","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eFSL100-UVIR\u003c\/span\u003e Honeywell FSL100 Series Flame Detector\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eHoneywell FSL100-UVIR\u003c\/span\u003e\u003c\/strong\u003e combines ultraviolet and infrared sensing technologies for industrial fire detection.\u003c\/p\u003e\n\n\u003cp\u003eThe detector delivers rapid flame recognition in hazardous operating environments.\u003c\/p\u003e\n\n\u003cp\u003eThe compact housing supports stable outdoor and indoor installation.\u003c\/p\u003e\n\n\u003cp\u003eThe detector minimizes false alarms through dual-spectrum analysis.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eFSL100 Series\u003c\/span\u003e\u003c\/strong\u003e detectors support critical plant safety strategies and fire shutdown systems.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineered Detection Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eDetects a 1 ft² n-heptane fire within 10 seconds\u003c\/li\u003e\n\u003cli\u003eDetection range reaches 25 meters for UV\/IR applications\u003c\/li\u003e\n\u003cli\u003e90-degree cone of vision improves area coverage\u003c\/li\u003e\n\u003cli\u003eFast alarm response improves equipment protection\u003c\/li\u003e\n\u003cli\u003eIntegrated optical supervision improves operational reliability\u003c\/li\u003e\n\u003cli\u003eBuilt-in automatic self-test supports continuous monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCore Technical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eFSL100-UVIR\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e FSL100 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector Type:\u003c\/strong\u003e UV\/IR Flame Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 10-28 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 12-24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Distance:\u003c\/strong\u003e 25 m \/ 80 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField of View:\u003c\/strong\u003e 90° horizontal and vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Glass Reinforced Polyester\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Protection:\u003c\/strong\u003e UV resistant and self-extinguishing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Outputs:\u003c\/strong\u003e Alarm relay and fault relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Output:\u003c\/strong\u003e 4-20 mA stepped output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStartup Time:\u003c\/strong\u003e Less than 10 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Response Time:\u003c\/strong\u003e 8 to 30 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Current:\u003c\/strong\u003e 25 mA at 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Current:\u003c\/strong\u003e ±75 mA at 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Entry:\u003c\/strong\u003e M20 gland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 465 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 125 × 80 × 57 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eVisual Status and Diagnostic Intelligence\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe detector provides local LED indicators for rapid field diagnostics.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eGreen LED indicates normal operation\u003c\/li\u003e\n\u003cli\u003eYellow LED identifies fault conditions\u003c\/li\u003e\n\u003cli\u003eFlashing yellow LED requests self-test verification\u003c\/li\u003e\n\u003cli\u003eRed LED confirms alarm condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe integrated self-test function reduces manual inspection frequency.\u003c\/p\u003e\n\n\u003cp\u003eOptical fault detection improves preventive maintenance efficiency.\u003c\/p\u003e\n\n\u003cp\u003e4-20 mA signaling simplifies remote system diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:#c00000;\"\u003eFSL100-UVIR\u003c\/span\u003e\u003c\/strong\u003e performs effectively in facilities requiring stable flame discrimination.\u003c\/p\u003e\n\n\u003cp\u003eThe detector suits applications with strong ambient light interference.\u003c\/p\u003e\n\n\u003cp\u003eEngineers value the fast optical response and integrated self-testing capability.\u003c\/p\u003e\n\n\u003cp\u003eThe dual-spectrum sensing method improves detection stability near hydrocarbon risks.\u003c\/p\u003e\n\n\u003cp\u003eThe compact structure simplifies retrofit projects inside existing fire systems.\u003c\/p\u003e\n\n\u003cp\u003eThe detector integrates efficiently with industrial PLC and fire control platforms.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRecommended Equipment Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eFire alarm control panels\u003c\/li\u003e\n\u003cli\u003eIndustrial PLC systems\u003c\/li\u003e\n\u003cli\u003eDCS safety monitoring systems\u003c\/li\u003e\n\u003cli\u003eGas turbine protection systems\u003c\/li\u003e\n\u003cli\u003eFuel storage monitoring systems\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown systems\u003c\/li\u003e\n\u003cli\u003eIndustrial burner management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eOil and gas processing facilities\u003c\/li\u003e\n\u003cli\u003ePetrochemical plants\u003c\/li\u003e\n\u003cli\u003ePower generation stations\u003c\/li\u003e\n\u003cli\u003eFuel loading terminals\u003c\/li\u003e\n\u003cli\u003eOffshore production platforms\u003c\/li\u003e\n\u003cli\u003eChemical manufacturing plants\u003c\/li\u003e\n\u003cli\u003eIndustrial boiler protection systems\u003c\/li\u003e\n\u003cli\u003eHazardous material storage areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Mechanical Durability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eUV-resistant enclosure supports outdoor installation\u003c\/li\u003e\n\u003cli\u003ePressure compensating element reduces internal moisture build-up\u003c\/li\u003e\n\u003cli\u003eSelf-extinguishing housing improves fire resistance\u003c\/li\u003e\n\u003cli\u003eIP65 protection supports dusty industrial locations\u003c\/li\u003e\n\u003cli\u003eStainless steel fixings improve long-term durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eIntegration and Wiring Flexibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eSupports relay-based alarm integration\u003c\/li\u003e\n\u003cli\u003eCompatible with PLC analog input modules\u003c\/li\u003e\n\u003cli\u003eSupports end-of-line resistor configurations\u003c\/li\u003e\n\u003cli\u003eSuitable for centralized fire monitoring systems\u003c\/li\u003e\n\u003cli\u003eFlexible terminal support simplifies field wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping and Warranty Support\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e12-month warranty included\u003c\/li\u003e\n\u003cli\u003eFast dispatch within 24-48 hours\u003c\/li\u003e\n\u003cli\u003eWorldwide shipping available\u003c\/li\u003e\n\u003cli\u003eDelivery supported by FedEx, UPS, and DHL\u003c\/li\u003e\n\u003cli\u003eProtective industrial export packaging included\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSelection Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eSelect UV\/IR technology for hydrocarbon fire environments\u003c\/li\u003e\n\u003cli\u003eUse IR3 models for extended detection distance requirements\u003c\/li\u003e\n\u003cli\u003eVerify PLC analog input compatibility before installation\u003c\/li\u003e\n\u003cli\u003eConsider ambient temperature and enclosure exposure conditions\u003c\/li\u003e\n\u003cli\u003eChoose relay configuration according to fire panel logic\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow does UV\/IR sensing improve flame verification?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe detector compares ultraviolet and infrared signatures to reduce nuisance alarms.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat installation position improves detection stability?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eInstall the detector with clear visibility toward the primary hazard area.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan the detector operate near high-temperature industrial equipment?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes. The operating range supports demanding industrial thermal environments.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy is the pressure compensating element important?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eIt prevents internal condensation caused by ambient pressure fluctuations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat factors should engineers evaluate before selecting this detector?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eReview hazard type, mounting distance, communication method, and environmental exposure.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45138162417846,"sku":"FSL100-UVIR","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/FSL100-UVIR.jpg?v=1779438206","url":"https:\/\/www.plcsparehub.com\/products\/fsl100-uvir-honeywell-fsl100-flame-detector-uvir-fire-safety-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}