{"product_id":"fc-fanwr-24r-honeywell-fan-assembly-kit-24vdc-cooling-unit","title":"FC-FANWR-24R Honeywell Fan Assembly Kit 24VDC Cooling Unit","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview | Dual-Fan Cooling and Monitoring Assembly\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eHoneywell FC-FANWR-24R\u003c\/span\u003e\u003c\/strong\u003e is a 24 VDC fan assembly kit for industrial control equipment. It provides forced-air cooling and integrated fan-status monitoring.\u003c\/p\u003e\n\u003cp\u003eThe assembly contains \u003cstrong\u003etwo Papst 4184N\/17X ball-bearing fans\u003c\/strong\u003e and a dedicated \u003cstrong\u003ePCB 07209\u003c\/strong\u003e. Both fans mount on a common mounting plate. This arrangement provides a compact cooling unit with centralized electrical connections.\u003c\/p\u003e\n\u003cp\u003eThe fan electronics monitor the rotational speed of each fan. A dedicated green LED indicates whether each fan exceeds its minimum operating speed. When both fans meet the speed threshold, the potential-free readback contact closes.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eFC-FANWR-24R\u003c\/span\u003e\u003c\/strong\u003e combines cooling performance with electrical status feedback. It helps maintenance teams monitor fan operation without relying solely on visual inspection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications | Product Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eFC-FANWR-24R\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Reference\u003c\/td\u003e\n\u003ctd\u003eFS-FANWR-24R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFan Assembly Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan Manufacturer\u003c\/td\u003e\n\u003ctd\u003ePapst\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan Model\u003c\/td\u003e\n\u003ctd\u003e4184N\/17X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan Bearing\u003c\/td\u003e\n\u003ctd\u003eBall Bearing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinger Guard Manufacturer\u003c\/td\u003e\n\u003ctd\u003ePapst\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinger Guard Model\u003c\/td\u003e\n\u003ctd\u003eLZ30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal PCB\u003c\/td\u003e\n\u003ctd\u003e07209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Fans\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e12–29 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e9.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Rating\u003c\/td\u003e\n\u003ctd\u003e2 A slow-blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Dimensions\u003c\/td\u003e\n\u003ctd\u003e5 × 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Airflow\u003c\/td\u003e\n\u003ctd\u003e360 m³\/h (211.8 CFM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003e52 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Fan Speed\u003c\/td\u003e\n\u003ctd\u003e3,200 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Readback Speed\u003c\/td\u003e\n\u003ctd\u003e1,500 RPM ±100 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +75°C (-22°F to +167°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 40°C\u003c\/td\u003e\n\u003ctd\u003e85,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 75°C\u003c\/td\u003e\n\u003ctd\u003e37,500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e391 × 142 × 51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (Imperial)\u003c\/td\u003e\n\u003ctd\u003e15.4 × 5.59 × 2.01 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Architecture | Fan and PCB Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe assembly integrates two axial fans with a dedicated monitoring circuit. Both fans share one mounting plate and electrical interface.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan Configuration:\u003c\/strong\u003e Two Papst 4184N\/17X ball-bearing fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring PCB:\u003c\/strong\u003e PCB 07209 processes fan-status signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Support:\u003c\/strong\u003e Common mounting plate supports both fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinger Protection:\u003c\/strong\u003e Papst LZ30 finger guards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Interface:\u003c\/strong\u003e Four-pole connector for external power and feedback wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Dimensions:\u003c\/strong\u003e 391 × 142 × 51 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe common mounting arrangement simplifies mechanical installation. The four-pole connector provides a centralized interface for power and status wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCooling Performance | Airflow and Operating Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe two-fan assembly delivers a combined airflow of \u003cstrong\u003e360 m³\/h\u003c\/strong\u003e. This equals approximately \u003cstrong\u003e211.8 CFM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance Item\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Fans\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Rotational Speed\u003c\/td\u003e\n\u003ctd\u003e3,200 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Monitoring Threshold\u003c\/td\u003e\n\u003ctd\u003e1,500 RPM ±100 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombined Airflow\u003c\/td\u003e\n\u003ctd\u003e360 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow in CFM\u003c\/td\u003e\n\u003ctd\u003e211.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombined Noise Level\u003c\/td\u003e\n\u003ctd\u003e52 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe airflow specification describes the complete assembly. It does not represent the airflow of each individual fan.\u003c\/p\u003e\n\u003cp\u003eEngineers should consider cabinet ventilation, inlet restrictions, filter resistance, and internal heat generation. These factors influence actual cooling performance after installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFan Monitoring | LED Indication and Readback Contact\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eFC-FANWR-24R\u003c\/span\u003e\u003c\/strong\u003e includes individual fan-speed indication and a potential-free readback contact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndividual LED Indication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEach fan has an associated green LED.\u003c\/li\u003e\n\u003cli\u003eThe LED illuminates when its fan exceeds the minimum speed.\u003c\/li\u003e\n\u003cli\u003eEach indicator provides direct visual confirmation of fan rotation speed status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePotential-Free Readback Contact\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe contact closes when both fans exceed the minimum speed threshold.\u003c\/li\u003e\n\u003cli\u003eThe contact also closes for approximately 15 seconds during power-up.\u003c\/li\u003e\n\u003cli\u003eThe contact provides a remote status interface for external monitoring circuits.\u003c\/li\u003e\n\u003cli\u003eThe contact supports a maximum switching voltage of 300 VDC or 240 VAC.\u003c\/li\u003e\n\u003cli\u003eThe maximum switching current is 0.5 A.\u003c\/li\u003e\n\u003cli\u003eThe maximum switching power is 10 W.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe minimum monitoring threshold is \u003cstrong\u003e1,500 RPM ±100 RPM\u003c\/strong\u003e. Both fans must satisfy this condition for normal readback closure after the startup period.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e The startup contact closure lasts approximately 15 seconds. Do not interpret this temporary signal as proof of sustained fan operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Interface | Power Supply and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted Voltage Range\u003c\/td\u003e\n\u003ctd\u003e12–29 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e9.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003e2 A slow-blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Size\u003c\/td\u003e\n\u003ctd\u003e5 × 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eNot provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connector\u003c\/td\u003e\n\u003ctd\u003eFour-pole connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Stripping Length\u003c\/td\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Tightening Torque\u003c\/td\u003e\n\u003ctd\u003e0.4–0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Screwdriver\u003c\/td\u003e\n\u003ctd\u003eSD 0.6 × 3.5 – DIN 5264\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eCritical Wiring Precaution:\u003c\/strong\u003e The assembly does not provide reverse polarity protection. Verify DC polarity before connecting the power supply.\u003c\/p\u003e\n\u003cp\u003eUse the specified fuse rating and connector wiring arrangement. Incorrect polarity or unsuitable protection may damage the fan electronics.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide | Mechanical and Electrical Connection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the Model:\u003c\/strong\u003e Confirm the assembly reference and required mounting dimensions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the Assembly:\u003c\/strong\u003e Check both fans, finger guards, PCB, and mounting plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the Mounting Position:\u003c\/strong\u003e Ensure sufficient clearance for airflow and maintenance access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure the Unit:\u003c\/strong\u003e Install the assembly using the equipment manufacturer's mounting instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare Wiring:\u003c\/strong\u003e Strip external wires to the specified 7 mm length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect Power:\u003c\/strong\u003e Verify 24 VDC polarity and supply compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect Readback:\u003c\/strong\u003e Wire the potential-free contact to the designated monitoring circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTighten Terminals:\u003c\/strong\u003e Apply 0.4–0.5 Nm tightening torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck Protection:\u003c\/strong\u003e Confirm the 2 A slow-blow fuse specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestore Power:\u003c\/strong\u003e Observe both fan indicators and verify the readback signal.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFollow the equipment manufacturer's installation drawings for mounting orientation and terminal assignments. Do not rely on connector position alone.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance | Practical Inspection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCommissioning should verify airflow, rotational speed, electrical supply, and remote status feedback.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Measurement:\u003c\/strong\u003e Confirm the input remains within 12–29 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStartup Observation:\u003c\/strong\u003e Allow for the approximately 15-second startup contact behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Inspection:\u003c\/strong\u003e Confirm that both green LEDs indicate sufficient fan speed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed Verification:\u003c\/strong\u003e Check the minimum threshold of 1,500 RPM ±100 RPM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Testing:\u003c\/strong\u003e Verify readback closure when both fans reach the required speed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow Inspection:\u003c\/strong\u003e Check for blocked inlets, restricted outlets, or dust accumulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Assessment:\u003c\/strong\u003e Investigate unusual vibration or changes in operating noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Inspection:\u003c\/strong\u003e Check connector tightness, fuse condition, and polarity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInspect the fan assembly during scheduled equipment maintenance. Replace damaged fans or guards according to the equipment manufacturer's service procedures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Mechanical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Item\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Specified Temperature\u003c\/td\u003e\n\u003ctd\u003e75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 40°C\u003c\/td\u003e\n\u003ctd\u003e85,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 75°C\u003c\/td\u003e\n\u003ctd\u003e37,500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Length\u003c\/td\u003e\n\u003ctd\u003e391 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Width\u003c\/td\u003e\n\u003ctd\u003e142 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Depth\u003c\/td\u003e\n\u003ctd\u003e51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe IP20 rating provides basic protection against finger access. It does not provide protection against water ingress.\u003c\/p\u003e\n\u003cp\u003eInstall the assembly inside a suitable enclosure. Prevent direct exposure to liquids, excessive dust, and mechanical impact.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eFC-FANWR-24R\u003c\/span\u003e\u003c\/strong\u003e provides cooling and status feedback for compatible Honeywell equipment configurations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Compatibility:\u003c\/strong\u003e The external supply must provide 12–29 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Supply:\u003c\/strong\u003e 24 VDC is the specified nominal operating voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring Interface:\u003c\/strong\u003e The potential-free contact supports external status monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Loading:\u003c\/strong\u003e External circuits must respect the contact's switching limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Compatibility:\u003c\/strong\u003e Verify the 391 × 142 × 51 mm mounting envelope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Identification:\u003c\/strong\u003e Confirm FC-FANWR-24R and FS-FANWR-24R references before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume universal compatibility across Honeywell controller platforms. Confirm the original equipment model, mounting arrangement, connector wiring, and approved replacement reference.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification and Compliance Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Supply:\u003c\/strong\u003e 24 VDC nominal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Capability:\u003c\/strong\u003e -30°C to +75°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Consideration:\u003c\/strong\u003e Reverse polarity protection is not provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e Confirm applicable approvals through the exact manufacturer documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe supplied technical information does not identify specific CE, UL, ATEX, or IECEx approvals. Verify certification requirements before installation in regulated environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging and Delivery Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Honeywell \u003cstrong\u003e\u003cspan style=\"color: #008080;\"\u003eFC-FANWR-24R\u003c\/span\u003e\u003c\/strong\u003e Fan Assembly Kit.\u003c\/li\u003e\n\u003cli\u003eIntegrated dual-fan assembly.\u003c\/li\u003e\n\u003cli\u003eTwo Papst 4184N\/17X fans.\u003c\/li\u003e\n\u003cli\u003ePCB 07209 and mounting plate.\u003c\/li\u003e\n\u003cli\u003ePapst LZ30 finger guards.\u003c\/li\u003e\n\u003cli\u003eProtective packaging for transportation.\u003c\/li\u003e\n\u003cli\u003e12-month warranty.\u003c\/li\u003e\n\u003cli\u003eShipping options through DHL, FedEx, or UPS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm the actual shipment contents and connector accessories before ordering. Contact our team for availability and delivery information.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions | Engineering and Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why does the readback contact close during startup even when the fans have not reached normal speed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitoring circuit closes the contact for approximately 15 seconds during power-up. This behavior forms part of the specified startup sequence. Engineers should evaluate the contact after this initial period.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What does it mean when one green LED illuminates but the other remains OFF?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe illuminated LED indicates that its associated fan exceeds the minimum speed threshold. The other fan may have insufficient speed or a mechanical problem. Inspect its supply, connector, rotor movement, and airflow path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the readback contact directly power an external alarm or relay?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe contact provides a potential-free switching interface. Its maximum ratings are 300 VDC or 240 VAC, 0.5 A, and 10 W. Verify all three limits before connecting an external circuit. Use an appropriate interface relay when necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should maintenance engineers check when the assembly produces abnormal noise?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect the fan bearings, mounting plate, finger guards, and surrounding enclosure. Check for dust accumulation and mechanical contact. Compare operating noise with the specified 52 dB assembly rating under comparable conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Why must engineers avoid connecting the power supply with reversed polarity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe assembly does not include reverse polarity protection. Incorrect polarity can damage its internal electronics. Verify positive and negative connections with a meter before energizing the unit.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/FC-FANWR-24R.png?v=1795419922\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68128806994102,"sku":"FC-FANWR-24R","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/FC-FANWR-24R-1.jpg?v=1795419922","url":"https:\/\/www.plcsparehub.com\/products\/fc-fanwr-24r-honeywell-fan-assembly-kit-24vdc-cooling-unit","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}