{"product_id":"fc-dr985-aera-digital-mfc-mass-flow-controller-fc-dr980-series","title":"FC-DR985 AERA Digital MFC Mass Flow Controller FC-DR980 Series","description":"\u003ch3\u003e\u003cb\u003eEngineering Specification: \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eFC-DR985\u003c\/b\u003e\u003c\/font\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eEngineered by \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eAERA\u003c\/b\u003e\u003c\/font\u003e as an advanced compact variant within the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eFC-DR980 Series\u003c\/b\u003e\u003c\/font\u003e, the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eFC-DR985\u003c\/b\u003e\u003c\/font\u003e is a high-performance digital mass flow controller. It integrates all-metal sealing, piezoelectric actuation, and multi-gas programmability to deliver precise, drift-resistant gas delivery for semiconductor processing tools, including CVD, PVD, etching, and ion implantation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eMetrology \u0026amp; Flow Control Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003ePrecision thermal-mass metrology paired with dynamic piezoelectric valve actuation enables rapid stabilization and low-drift flow regulation across demanding operating profiles.\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cb\u003eFunctional Domain\u003c\/b\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cb\u003ePerformance Parameter\u003c\/b\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cb\u003eEngineering Specification\u003c\/b\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eIdentification\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eBrand \u0026amp; Exact Model\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cfont color=\"#0056b3\"\u003e\u003cb\u003eAERA\u003c\/b\u003e\u003c\/font\u003e \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eFC-DR985\u003c\/b\u003e\u003c\/font\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eIdentification\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eProduct Family \u0026amp; Architecture\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cfont color=\"#0056b3\"\u003e\u003cb\u003eFC-DR980 Series\u003c\/b\u003e\u003c\/font\u003e (Digital, Piezoelectric, Metal-Sealed)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eFlow Metrology\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eConfigurable Full-Scale Range\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e10 sccm to 5 slm\u003c\/b\u003e (Multi-gas \/ multi-range models 1-6, N2 equivalent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eFlow Metrology\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e≤ ±1% S.P.\u003c\/b\u003e (25–100% FS); \u003cb\u003e≤ ±0.25% FS\u003c\/b\u003e (2–25% FS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eFlow Metrology\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eSystem Repeatability\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e≤ ±0.15% FS\u003c\/b\u003e over operating span\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eDynamic Response\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eSettling Time (SEMI E17-91)\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e≤ 1.0 second typical\u003c\/b\u003e across full control range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eFluidic Ratings\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eOperating Differential Pressure\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e7 to 40 psiD\u003c\/b\u003e (49 to 275 kPaD); Max operating pressure \u003cb\u003e70 psiG\u003c\/b\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eMaterials \u0026amp; Integrity\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eWetted Path \u0026amp; Helium Leak Rate\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003eSUS316L\/316 Stainless Steel, PCTFE\u003c\/b\u003e (5 Ra finish); \u003cb\u003e≤ 1×10³¹\u0026amp;sup0; atm-cc\/sec\u003c\/b\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eElectrical \u0026amp; Control\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower Supply \u0026amp; Communication\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e+15 VDC (100 mA)\u003c\/b\u003e, \u003cb\u003e-15 VDC (40 mA)\u003c\/b\u003e; D-Sub 9 \u0026amp; RS-485 RJ-11\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eEnvironmental\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e15°C to 50°C\u003c\/b\u003e (59°F to 122°F); Zero stability \u0026lt;0.5% FS\/year\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eMechanical Mounting \u0026amp; Installation Protocol\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eCompact Form Factor:\u003c\/b\u003e Mount the unit using the standard \u003cb\u003e79.8 mm\u003c\/b\u003e port-to-port spacing, ensuring compatibility with tight IGS gas panel layouts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eConnector Flexibility:\u003c\/b\u003e Terminate control signals via the top (T) or side pigtail (Y) connector interface depending on cabinet clearance constraints.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eGas Programming:\u003c\/b\u003e Upload custom calibration tables supporting up to four distinct process gases with ten points per gas via digital commands.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003ePreventative Maintenance \u0026amp; Diagnostic Routines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eLeak Integrity Validation:\u003c\/b\u003e Perform scheduled helium mass spectrometry checks to verify metal seal integrity against the \u003cb\u003e1×10³¹¹ Pa-m³\/sec\u003c\/b\u003e threshold.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eZero Drift Audit:\u003c\/b\u003e Verify zero-point stability annually against the \u003cb\u003e\u0026lt;0.5% FS per year\u003c\/b\u003e benchmark under locked-valve conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eInline Filtration:\u003c\/b\u003e Ensure high-purity upstream gas filtration to prevent particulate accumulation on the piezoelectric valve seat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eApplication Engineering \u0026amp; System Compatibility\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eProcess Integration:\u003c\/b\u003e Purpose-built for semiconductor fabrication tools requiring high-density integration in sputtering, CVD, and diffusion systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eControl Versatility:\u003c\/b\u003e Supports both analog \u003cb\u003e0–5 VDC\u003c\/b\u003e loops and digital \u003cb\u003eRS-485\u003c\/b\u003e multi-drop networking protocols for automated fab environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eHardware Delivery Scope\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003e1 ×\u003c\/b\u003e \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eAERA\u003c\/b\u003e\u003c\/font\u003e \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eFC-DR985\u003c\/b\u003e\u003c\/font\u003e Digital Mass Flow Controller\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003e1 ×\u003c\/b\u003e Factory Calibration and Compliance Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eEngineering Selection Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eValve Fail-Safe Selection:\u003c\/b\u003e Choose between normally-open (NO) or normally-closed (NC) piezoelectric actuator configurations based on your tool's safety interlock requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eRange Scaling:\u003c\/b\u003e Verify that your process operating pressures fall within the \u003cb\u003e7 to 40 psiD\u003c\/b\u003e differential window to ensure linear control across the 2% to 100% turndown span.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eAdvanced Technical FAQ\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cp\u003e\u003cb\u003eQ: How does the piezoelectric actuator in the FC-DR985 differ from traditional thermal solenoid valves during fast recipe steps?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp\u003eA: The piezoelectric stack provides direct mechanical displacement with virtually zero thermal hysteresis, achieving a settling time of ≤1.0 second without overshoot during rapid gas switching.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp\u003e\u003cb\u003eQ: What field calibration steps are required when switching the FC-DR985 from Nitrogen to a reactive process gas like Silane?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp\u003eA: You can access the internal multi-gas memory via the RS-485 interface to load pre-calculated conversion factors and multi-point calibration tables without removing the unit from the gas box.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp\u003e\u003cb\u003eQ: Why does maintaining the differential pressure between 7 and 40 psiD critically impact controller linearity?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp\u003eA: Operating below 7 psiD starves the laminar flow element, causing measurement compression at high flow rates, while exceeding 40 psiD can introduce sonic choking across the valve orifice.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp\u003e\u003cb\u003eQ: What precautions should technicians observe when handling the unit's metal-sealed VCR connections during maintenance?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp\u003eA: Always replace the nickel or stainless steel gasket on every make-break cycle, and use backup wrenches to prevent twisting the internal manifold tubing.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp\u003e\u003cb\u003eQ: How does the dual RJ-11 port architecture streamline multi-drop networking on crowded gas racks?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp\u003eA: The dual RJ-11 ports enable straightforward daisy-chaining of RS-485 half-duplex communication lines between adjacent controllers, minimizing wiring harness congestion in narrow panels.\u003c\/p\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AERA","offers":[{"title":"Default Title","offer_id":68077760774326,"sku":"FC-DR985","price":330.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/FC-DR985_33d89e6e-cd9b-47b8-8e54-6dc0fb8df260.jpg?v=1794799066","url":"https:\/\/www.plcsparehub.com\/products\/fc-dr985-aera-digital-mfc-mass-flow-controller-fc-dr980-series","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}