{"product_id":"f3yd32-1p-high-reliability-sink-output-module-by-yokogawa-fa-m3","title":"F3YD32-1P High-Reliability Sink Output Module by Yokogawa FA-M3","description":"\u003ch3\u003e\u003cstrong\u003eF3YD32-1P | Yokogawa FA-M3 32-Point Transistor Output Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA F3YD32-1P\u003c\/strong\u003e is a 32-point transistor output module for the FA-M3 programmable controller platform. It provides 12–24 VDC sink-type outputs for controlling compatible field loads.\u003c\/p\u003e\n\u003cp\u003eThe module uses photocoupler isolation between the external connection terminals and internal circuitry. Its output architecture supports eight points per common, with a maximum load current of 0.1 A per point and 0.5 A per common.\u003c\/p\u003e\n\u003cp\u003eBuilt-in short-circuit and overheat protection help protect the output elements during abnormal load conditions. An active clamp circuit provides output surge protection. These functions make the module suitable for distributed DC control signals in machine automation and process equipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Output Architecture — 32 Channels, Four Common Groups\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe F3YD32-1P uses NPN-style sink output behavior. Each output switches its load return path, so the external load circuit must be wired for sink-type operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput technology:\u003c\/strong\u003e Transistor, sink type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput channels:\u003c\/strong\u003e 32 points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon arrangement:\u003c\/strong\u003e 8 points per common.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Photocoupler isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal load voltage:\u003c\/strong\u003e 12–24 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating voltage range:\u003c\/strong\u003e 10.2–26.4 VDC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 8-point common arrangement is important when distributing field power. Plan the external supply and load returns by common group rather than treating all 32 points as one unrestricted output bank.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Load Capacity and Switching Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOutput loading must remain within both the individual channel rating and the common-group rating. A channel may meet its individual current limit while the combined load exceeds the common limit.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current per point\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current per common\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-to-ON response\u003c\/td\u003e\n\u003ctd\u003e1 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-to-OFF response\u003c\/td\u003e\n\u003ctd\u003e1 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON voltage\u003c\/td\u003e\n\u003ctd\u003e0.5 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-state leakage current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor example, eight loads rated at 100 mA each would total 800 mA. This exceeds the 0.5 A common rating, even though each load is within the 0.1 A individual limit.\u003c\/p\u003e\n\u003cp\u003eCheck the actual operating current of solenoids, indicator lamps, and interface relays. Consider inrush current and the load manufacturer's electrical data before assigning output points.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Protection Design — Short Circuit, Overheat and Surge\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates several protective functions. They address different electrical fault conditions and should not be treated as interchangeable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection:\u003c\/strong\u003e Limits output current or temporarily turns the output off when an abnormal condition is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverheat protection:\u003c\/strong\u003e Turns off the affected output group when the output element temperature exceeds its protection threshold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge protection:\u003c\/strong\u003e Uses an active clamp circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse:\u003c\/strong\u003e No built-in fuse.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eShort-circuit protection operates individually on output points. Overheat protection operates in groups of eight points: OUT1–OUT8, OUT9–OUT16, OUT17–OUT24, and OUT25–OUT32.\u003c\/p\u003e\n\u003cp\u003eIf a short circuit remains, the output element may continue to heat up. The module should not be left in a prolonged short-circuit condition. Remove the fault and verify normal operation before returning the channel to service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInductive load warning:\u003c\/strong\u003e When driving a relay coil or another inductive load, install a suitable surge suppressor or diode across the load. The module's active clamp does not eliminate the need for appropriate load-side suppression.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | CPU Stop Behavior — HOLD or RESET\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe output state when the control program stops depends on the CPU type and its configuration. This behavior should be reviewed during machine safety and restart design.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSequence CPU:\u003c\/strong\u003e Initial setting is RESET. The output behavior can be configured globally on a module-by-module basis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBASIC CPU:\u003c\/strong\u003e No setting function is provided. The output state is always HOLD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOS-free CPU:\u003c\/strong\u003e Initial setting is HOLD. The state can be specified for each group of eight points.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume that every CPU automatically resets the outputs when the program stops. Verify the installed CPU type, module settings, and machine restart sequence.\u003c\/p\u003e\n\u003cp\u003eFor equipment controlling actuators or process valves, evaluate the consequences of both HOLD and RESET behavior. Use independent safety circuits where the application requires a defined safe state.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | External Wiring and Power Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe F3YD32-1P connects to external field wiring through one 40-pin connector. Correct connector wiring and supply polarity are essential to reliable operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal connection:\u003c\/strong\u003e One 40-pin connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal power supply:\u003c\/strong\u003e 12–24 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal supply current:\u003c\/strong\u003e 55 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal module consumption:\u003c\/strong\u003e 160 mA at 5 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput indication:\u003c\/strong\u003e LED, illuminated when the output is ON.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWithstand voltage:\u003c\/strong\u003e 1,500 VAC for one minute between the external connection terminal group and internal circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck the connector pin assignment before connecting a replacement cable. Yokogawa warns that a connector wired for F3XD32 or F3XD64 input modules must not be incorrectly connected to this output module. Incorrect wiring can disable protective functions and damage internal components.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Installation Environment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInstall the module in a control cabinet that meets the specified environmental conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0–55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -20–75°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating humidity:\u003c\/strong\u003e 10–90% RH, non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage humidity:\u003c\/strong\u003e 10–90% RH, non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAtmosphere:\u003c\/strong\u003e Free from corrosive gases, flammable gases, and heavy dust.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 110 g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaintain adequate cabinet ventilation. Avoid installation locations exposed to condensation, corrosive atmospheres, or excessive dust.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Typical Control Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 32-point sink output architecture is suitable for switching compatible DC field devices in automated equipment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolenoid valve control:\u003c\/strong\u003e Switching compatible 12–24 VDC valve coils within the current rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay interface control:\u003c\/strong\u003e Driving external interface relays with suitable coil suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine status outputs:\u003c\/strong\u003e Controlling DC indicator devices and status signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterlock circuits:\u003c\/strong\u003e Providing PLC output commands to external control interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed control panels:\u003c\/strong\u003e Organizing field outputs into four common groups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm load current, inductive characteristics, and external circuit protection before connecting field devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3YD32-1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eFA-M3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule type\u003c\/td\u003e\n\u003ctd\u003eTransistor output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput type\u003c\/td\u003e\n\u003ctd\u003eSink type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of points\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon arrangement\u003c\/td\u003e\n\u003ctd\u003e8 points\/common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation method\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand voltage\u003c\/td\u003e\n\u003ctd\u003e1,500 VAC, 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated load voltage\u003c\/td\u003e\n\u003ctd\u003e12–24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage range\u003c\/td\u003e\n\u003ctd\u003e10.2–26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum load current\u003c\/td\u003e\n\u003ctd\u003e0.1 A\/point; 0.5 A\/common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-to-ON response\u003c\/td\u003e\n\u003ctd\u003e1 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-to-OFF response\u003c\/td\u003e\n\u003ctd\u003e1 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON voltage\u003c\/td\u003e\n\u003ctd\u003e0.5 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-state leakage current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003ctd\u003eCurrent limiting or output shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverheat protection\u003c\/td\u003e\n\u003ctd\u003eOutput shutdown, 8-point group control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd\u003eActive clamp circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal current consumption\u003c\/td\u003e\n\u003ctd\u003e160 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal power supply\u003c\/td\u003e\n\u003ctd\u003e12–24 VDC, 55 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput indication\u003c\/td\u003e\n\u003ctd\u003eLED, ON when output is active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal connector\u003c\/td\u003e\n\u003ctd\u003eOne 40-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e110 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0–55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-20–75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e10–90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage humidity\u003c\/td\u003e\n\u003ctd\u003e10–90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating atmosphere\u003c\/td\u003e\n\u003ctd\u003eFree from corrosive gases, flammable gases, and heavy dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why does a field device fail to operate even when the output LED is illuminated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LED indicates the module's output command state, but it does not confirm that the complete field circuit is operating correctly. Check the external 12–24 VDC supply, load wiring, common connection, and device coil resistance. Measure the voltage across the load while the output is commanded ON. Also inspect connector wiring and external circuit continuity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the module directly drive a 24 VDC solenoid valve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt can drive a compatible valve coil if the steady-state current remains within 0.1 A per point and 0.5 A per common. Check the coil's inrush characteristics and switching requirements. Install a suitable suppression diode or surge suppressor across the coil. If the load exceeds the rating, use an appropriately rated interposing relay or driver.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Why might several outputs in the same group turn off together?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck whether the affected points share the same eight-point common group. A common wiring fault, excessive group loading, or overheat protection event can affect multiple outputs. Measure the total group current and inspect the wiring for short circuits. Compare the affected points with outputs in other groups to narrow down the fault location.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should be checked before replacing this module in an existing FA-M3 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the exact model suffix, output direction, connector wiring, external supply polarity, and CPU stop-state configuration. Do not substitute a source-type or TTL output module based only on its 32-point count. Also check the field cable against the correct output-module pin assignment before energizing the replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How should intermittent output shutdown be investigated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart by checking the load current under actual operating conditions. Inspect for intermittent cable shorts, loose terminals, damaged coil insulation, and excessive common-group loading. If shutdown occurs after several outputs operate together, check the eight-point group current and cabinet temperature. Remove the fault before testing again; repeated short-circuit operation can cause thermal damage.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Replacement and Ordering Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore selecting the F3YD32-1P for a replacement or expansion project, verify the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExact model number: F3YD32-1P.\u003c\/li\u003e\n\u003cli\u003eFA-M3 system and installed CPU compatibility.\u003c\/li\u003e\n\u003cli\u003e32-point transistor sink output requirement.\u003c\/li\u003e\n\u003cli\u003e12–24 VDC field supply and load polarity.\u003c\/li\u003e\n\u003cli\u003eMaximum current per point and per common.\u003c\/li\u003e\n\u003cli\u003e40-pin connector and field cable pin assignment.\u003c\/li\u003e\n\u003cli\u003eRequired HOLD or RESET behavior when the program stops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe F3YD32-1P is not a direct substitute for the F3YD32-1R source output version or the F3YD32-1T TTL output version. Confirm the output circuit before ordering.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68028123054262,"sku":"F3YD32-1P","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/F3YD32-1P-3.jpg?v=1794292178","url":"https:\/\/www.plcsparehub.com\/products\/f3yd32-1p-high-reliability-sink-output-module-by-yokogawa-fa-m3","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}