{"product_id":"f3yd32-1h-series-yokogawa-high-speed-digital-output-module","title":"F3YD32-1H Series Yokogawa High-Speed Digital Output Module","description":"\u003ch3\u003eEngineering Architecture \u0026amp; System Matrix\u003c\/h3\u003e\n\u003cp\u003eThe high-density \u003cstrong style=\"color: #0056b3;\"\u003eF3YD32-1H\u003c\/strong\u003e output card manufactured by \u003cstrong style=\"color: #0056b3;\"\u003eYokogawa\u003c\/strong\u003e operates as a 32-point \u003cstrong style=\"color: #0056b3;\"\u003eTransistor Output Module\u003c\/strong\u003e (Sink Type) within the advanced \u003cstrong style=\"color: #0056b3;\"\u003eFA-M3 Series\u003c\/strong\u003e automation architecture. Designed for ultra-fast switching applications, this module features built-in thermal and short-circuit protection circuits alongside active voltage clamping.\u003c\/p\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCatalog Model Code:\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003eF3YD32-1H\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer \u0026amp; Brand:\u003c\/strong\u003e Yokogawa Electric Corporation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Classification:\u003c\/strong\u003e FA-M3 High-Speed Sink Transistor Output Module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChannel Configuration:\u003c\/strong\u003e 32 total points organized in 8 points\/common grouping\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExternal Connection Interface:\u003c\/strong\u003e Single standard 40-pin flat ribbon connector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBackplane Current Consumption:\u003c\/strong\u003e 165 mA at 5 V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExternal Field Supply:\u003c\/strong\u003e 12 to 24 V DC at 30 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications \u0026amp; Performance Metrics\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003ePerformance Parameter\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eEngineering Specification\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12 to 24 V DC (Absolute operating range: 10.2 to 26.4 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eCurrent Capacity per Point\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.1 A per point maximum; 0.5 A maximum per common bus group\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eHigh-Speed Switching Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOFF→ON: 0.1 ms max.; ON→OFF: 0.1 ms max. ultra-fast transition\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eDielectric Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1,500 V AC for one minute between external terminals and internal logic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eVoltage Drop \u0026amp; Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.5 V DC max. ON voltage drop; 0.1 mA max. OFF-state leakage current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eBuilt-In Protectors\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShort-circuit current limiting (1–3 A) and thermal overheat auto-shutdown\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eSurge Suppression Network\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntegrated active clamp circuitry for inductive load transient absorption\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eEnvironmental Envelope\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating: 0 to 55°C (10 to 90% RH non-condensing); Storage: -20°C to 75°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eIndustrial Applications \u0026amp; Rotary Machinery\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Packaging \u0026amp; Sorting Lines:\u003c\/strong\u003e Drives high-frequency pneumatic valve manifolds and high-speed sorting gates requiring 0.1 ms response times.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSemiconductor Wafer Handlers:\u003c\/strong\u003e Controls precision DC actuators and optical indicators in cleanroom automation skids.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomated Robotic Cell Interfaces:\u003c\/strong\u003e Interfaces PLC logic directly with high-density transistor sink inputs on peripheral motion controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDiagnostic Capabilities \u0026amp; Protection Modes\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Stage Short-Circuit Protection:\u003c\/strong\u003e Automatically limits short-circuit fault current between 1 A and 3 A while raising channel voltage drop.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Overheat Shutdown:\u003c\/strong\u003e Shuts down individual output elements if prolonged shorts drive internal temperatures up to ~160°C, auto-recovering upon cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVisual Status Annunciation:\u003c\/strong\u003e Front-panel LEDs provide direct visual confirmation when individual output channels are energized.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eWhen implementing high-density sink outputs like the \u003cstrong style=\"color: #0056b3;\"\u003eF3YD32-1H\u003c\/strong\u003e, signal timing and thermal protection behavior require careful engineering. This module achieves a blazing 0.1 ms switching response, making it ideal for high-speed pulse applications, but field wiring must utilize properly shielded 40-pin pre-wired cables to prevent crosstalk. While the card features robust built-in short-circuit current limiting (1–3 A) and overheat auto-shutdown (~160°C trigger), field technicians should never treat these protective states as normal operating modes; leaving outputs in a sustained short-circuit condition will accelerate component thermal aging. Always verify that common bus loads remain under the 0.5 A per-common limit to maintain long-term reliability.\u003c\/p\u003e\n\n\u003ch3\u003eLogistics, Packaging \u0026amp; Warranty Terms\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondition Status:\u003c\/strong\u003e 100% New \u0026amp; Original factory-sealed equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e Comprehensive 12 Months factory warranty from date of purchase.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrder Handling:\u003c\/strong\u003e Rapid 24 to 48 hour processing and dispatch window.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Express Shipping:\u003c\/strong\u003e Fast, secure air delivery worldwide via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003ch3\u003eHow does sink-type transistor wiring direct current across the load?\u003c\/h3\u003e\n\u003cp\u003eIn a sink-type configuration, the external load connects between the positive power supply rail and the module's output terminal, allowing the internal transistor to pull current down to the 0V common rail.\u003c\/p\u003e\n\n\u003ch3\u003eWhat specific protective actions occur if an output channel experiences a short-circuit?\u003c\/h3\u003e\n\u003cp\u003eThe module immediately limits short-circuit current to a safe 1–3 A range; if the short persists and junction temperature reaches ~160°C, the overheat protector shuts down the output until it cools by ~10°C.\u003c\/p\u003e\n\n\u003ch3\u003eWhy is the 40-pin connector configuration advantageous for 32-point modules?\u003c\/h3\u003e\n\u003cp\u003eUsing a single 40-pin flat ribbon connector significantly reduces cabinet wiring time and eliminates bulky individual terminal blocks while housing 32 high-speed channels in a single slot.\u003c\/p\u003e\n\n\u003ch3\u003eHow do CPU stop settings handle module outputs when program execution halts?\u003c\/h3\u003e\n\u003cp\u003eFor sequence CPUs, output states default to RESET but can be set collectively; BASIC CPUs default to HOLD; and OS-free CPUs allow independent 8-point block configuration.\u003c\/p\u003e\n\n\u003ch3\u003eWhat guidelines prevent thermal stress on the module's 0.5 A common current limit?\u003c\/h3\u003e\n\u003cp\u003eEnsure that the sum of operating currents for all active channels within any 8-point common group does not exceed 0.5 A simultaneously to prevent internal trace overheating.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67878845546678,"sku":"F3YD32-1H","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/F3YD32-1H-1.jpg?v=1793173442","url":"https:\/\/www.plcsparehub.com\/products\/f3yd32-1h-series-yokogawa-high-speed-digital-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}