{"product_id":"f3xh04-3n-yokogawa-fa-m3-pulse-input-module-24v-dc-4-channel","title":"F3XH04-3N Yokogawa FA-M3 Pulse Input Module 24V DC 4-Channel","description":"\u003ch3\u003e\u003cb\u003eYokogawa F3XH04-3N | High-Speed Pulse Input for FA-M3\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003eYokogawa F3XH04-3N\u003c\/b\u003e is a 4-channel high-speed digital input module for the FA-M3 programmable controller platform. It accepts 24 V DC signals and detects short-duration pulses that may be missed during a normal PLC scan.\u003c\/p\u003e\n\u003cp\u003eWith a minimum input pulse width of 50 μs, photocoupler isolation, and four independent input circuits, this module supports fast event detection in industrial automation systems. Its pulse-capture and interrupt functions help the controller respond to brief input transitions without relying solely on routine scan-based processing.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eEngineering highlight:\u003c\/b\u003e Pulse-capture and interrupt functions cannot operate simultaneously. Select the required operating mode according to the application, configure the module correctly, and verify the signal timing during commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e01 | Signal Acquisition at a Glance\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 99.9421%; height: 294px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 17.7681%; height: 19.6px;\"\u003eFunction\u003c\/th\u003e\n\u003cth style=\"width: 28.4312%; height: 19.6px;\"\u003eEngineering Value\u003c\/th\u003e\n\u003cth style=\"width: 51.1341%; height: 19.6px;\"\u003eWhy It Matters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 17.7681%; height: 39.2px;\"\u003eInput channels\u003c\/td\u003e\n\u003ctd style=\"width: 28.4312%; height: 39.2px;\"\u003e4 independent inputs\u003c\/td\u003e\n\u003ctd style=\"width: 51.1341%; height: 39.2px;\"\u003eAllows signals from separate field devices to be connected to individual input points.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 17.7681%; height: 39.2px;\"\u003eRated input voltage\u003c\/td\u003e\n\u003ctd style=\"width: 28.4312%; height: 39.2px;\"\u003e24 V DC\u003c\/td\u003e\n\u003ctd style=\"width: 51.1341%; height: 39.2px;\"\u003eSuitable for compatible 24 V DC industrial switching signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 17.7681%; height: 39.2px;\"\u003eMinimum pulse width\u003c\/td\u003e\n\u003ctd style=\"width: 28.4312%; height: 39.2px;\"\u003e50 μs\u003c\/td\u003e\n\u003ctd style=\"width: 51.1341%; height: 39.2px;\"\u003eSupports detection of short pulses that may occur between routine PLC scans.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 17.7681%; height: 39.2px;\"\u003eInput response time\u003c\/td\u003e\n\u003ctd style=\"width: 28.4312%; height: 39.2px;\"\u003e50 μs maximum, OFF to ON and ON to OFF\u003c\/td\u003e\n\u003ctd style=\"width: 51.1341%; height: 39.2px;\"\u003eProvides a reference for evaluating input timing requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 17.7681%; height: 39.2px;\"\u003eInput hold time\u003c\/td\u003e\n\u003ctd style=\"width: 28.4312%; height: 39.2px;\"\u003e512 μs after an OFF-to-ON transition\u003c\/td\u003e\n\u003ctd style=\"width: 51.1341%; height: 39.2px;\"\u003eHolds the detected input signal for the specified period to support processing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 17.7681%; height: 39.2px;\"\u003eIsolation\u003c\/td\u003e\n\u003ctd style=\"width: 28.4312%; height: 39.2px;\"\u003ePhotocoupler isolation\u003c\/td\u003e\n\u003ctd style=\"width: 51.1341%; height: 39.2px;\"\u003eProvides electrical isolation between the input circuitry and internal logic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 17.7681%; height: 39.2px;\"\u003eOperating mode selection\u003c\/td\u003e\n\u003ctd style=\"width: 28.4312%; height: 39.2px;\"\u003eDIP switches\u003c\/td\u003e\n\u003ctd style=\"width: 51.1341%; height: 39.2px;\"\u003eUsed to select the supported pulse-capture or interrupt function.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e02 | Electrical Interface and Switching Thresholds\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput type\u003c\/td\u003e\n\u003ctd\u003eDC voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage range\u003c\/td\u003e\n\u003ctd\u003e20.4–26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current\u003c\/td\u003e\n\u003ctd\u003e11.2 mA per point at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e2.1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-state threshold\u003c\/td\u003e\n\u003ctd\u003e16.0 V DC minimum; 7.2 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-state threshold\u003c\/td\u003e\n\u003ctd\u003e6.0 V DC maximum; 2.5 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e30 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal connection\u003c\/td\u003e\n\u003ctd\u003e10-point terminal block with M3.5 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 130 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eSignal-level check:\u003c\/b\u003e The stated ON and OFF thresholds define the expected input states. When a field signal falls between the specified OFF and ON limits, do not assume a guaranteed logic state. Check the sensor output, voltage drop, common wiring, and signal waveform.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03 | Timing Logic: From Field Pulse to PLC Processing\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is designed for applications where short input events require more attention than ordinary scan-based digital input processing can provide.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cb\u003eField event:\u003c\/b\u003e A photoelectric sensor, proximity switch, or compatible pulse source generates a 24 V DC transition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eElectrical detection:\u003c\/b\u003e The input circuit evaluates the voltage and current against its specified switching thresholds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHigh-speed capture:\u003c\/b\u003e The pulse-capture function detects a qualifying transition even when its ON duration is shorter than the normal PLC scan period.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProcessing support:\u003c\/b\u003e The detected state is held for 512 μs after an OFF-to-ON transition, according to the module specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eApplication response:\u003c\/b\u003e The PLC program processes the captured input according to the configured system logic.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe F3XH04-3N also supports an interrupt function. This can be useful when the application requires event-driven processing. The pulse-capture and interrupt functions are mutually exclusive, so the required mode must be selected before commissioning.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eTiming caution:\u003c\/b\u003e The 50 μs minimum pulse width is an input detection specification, not a guarantee that the complete PLC application will respond within 50 μs. Program execution, interrupt handling, communication, and output-device response introduce additional timing considerations.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04 | Configuration and Wiring Requirements\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration Item\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule model\u003c\/td\u003e\n\u003ctd\u003eF3XH04-3N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule family\u003c\/td\u003e\n\u003ctd\u003eYokogawa FA-M3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse-capture selection\u003c\/td\u003e\n\u003ctd\u003eSelected by DIP switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt selection\u003c\/td\u003e\n\u003ctd\u003eSelected by DIP switches; set for each point through the FA-M3 programming tool WideField3, according to the supplied configuration information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField terminal type\u003c\/td\u003e\n\u003ctd\u003e10-point terminal block, M3.5 screw connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable conductor size\u003c\/td\u003e\n\u003ctd\u003e0.33–0.82 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring method\u003c\/td\u003e\n\u003ctd\u003eSolderless terminal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended crimping torque\u003c\/td\u003e\n\u003ctd\u003e0.8 N·m (8 kgf·cm, 6.9 lbf·in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed solderless terminals\u003c\/td\u003e\n\u003ctd\u003eV1.25-M3 (Japan Solderless Terminal Mfg. Co., Ltd.) or RAV1.25-3.5 (Nippon Tanshi Co., Ltd.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe terminal block includes terminals intended for shielded cable connections. Follow the equipment wiring diagrams for shield termination, signal routing, and grounding. Keep high-speed signal wiring away from strong electrical noise sources where practical.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBefore energizing:\u003c\/b\u003e Confirm terminal assignments, field polarity, input voltage, DIP switch positions, and program configuration against the applicable Yokogawa documentation. Do not infer terminal functions from terminal count alone.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | FA-M3 Integration and Application Fit\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer specifies no restriction on the type of CPU module that can be used with the F3XH04-3N. The complete installation must still comply with the selected FA-M3 configuration, system documentation, and application requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePhotoelectric sensing:\u003c\/b\u003e Captures short pulses from photo-micro switches and compatible photoelectric sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProximity detection:\u003c\/b\u003e Detects brief switching events from compatible 24 V DC proximity sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePart counting:\u003c\/b\u003e Supports fast event acquisition on production lines where short sensor pulses may be missed by routine scan-based inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePosition and sequence detection:\u003c\/b\u003e Monitors short-duration switching events used in indexing, sorting, and machine sequencing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEvent-driven control:\u003c\/b\u003e Supports interrupt-based processing where the application benefits from a configured response to an input event.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndustrial inspection equipment:\u003c\/b\u003e Acquires rapid sensor transitions for synchronized handling or inspection sequences.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eSelection boundary:\u003c\/b\u003e This is a discrete DC input module, not a general-purpose analog input module or a dedicated high-speed counter specification. If the application requires frequency measurement, pulse accumulation, quadrature decoding, or a defined maximum count rate, verify those capabilities separately before selection.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | Operating Environment\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironmental Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating ambient temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\u003ctd\u003e10–90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity\u003c\/td\u003e\n\u003ctd\u003e10–90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmosphere\u003c\/td\u003e\n\u003ctd\u003eMust be free of corrosive gases, flammable gases, and heavy dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eInstall the module in an environment that meets the specified temperature, humidity, and atmospheric conditions. Assess enclosure ventilation, cabinet contamination, and electrical noise where high-speed signals are involved.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e07 | Diagnostic Matrix for Commissioning and Maintenance\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSymptom\u003c\/th\u003e\n\u003cth\u003ePossible Cause\u003c\/th\u003e\n\u003cth\u003eRecommended Diagnostic Action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eA short pulse is not detected\u003c\/td\u003e\n\u003ctd\u003ePulse width below the supported minimum, incorrect mode selection, or unsuitable signal level\u003c\/td\u003e\n\u003ctd\u003eMeasure the pulse waveform and verify the 50 μs minimum pulse width, input thresholds, and DIP switch configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput state appears inconsistent\u003c\/td\u003e\n\u003ctd\u003eField voltage near the switching threshold, noise, poor terminal contact, or unstable sensor output\u003c\/td\u003e\n\u003ctd\u003eMeasure voltage at the module terminals during switching. Inspect the wiring, terminal tightness, and sensor supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt routine does not execute as expected\u003c\/td\u003e\n\u003ctd\u003eIncorrect interrupt configuration, program setup, or selected operating mode\u003c\/td\u003e\n\u003ctd\u003eVerify the point configuration in WideField3, DIP switch settings, and the application’s interrupt handling logic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse-capture behavior is unavailable\u003c\/td\u003e\n\u003ctd\u003eInterrupt mode selected instead of pulse-capture mode, or incorrect setup\u003c\/td\u003e\n\u003ctd\u003eConfirm the required function and recheck the mutually exclusive mode selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput remains OFF despite a sensor event\u003c\/td\u003e\n\u003ctd\u003eIncorrect polarity, insufficient ON-state voltage\/current, broken wiring, or an incompatible output type\u003c\/td\u003e\n\u003ctd\u003eCheck the sensor output specification and measure the voltage and current delivered to the input.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent false transitions occur\u003c\/td\u003e\n\u003ctd\u003eElectrical interference, poor shielding, loose wiring, or unstable field signals\u003c\/td\u003e\n\u003ctd\u003eInspect cable routing, shielding, terminal connections, and the sensor waveform under operating conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eDiagnostic method:\u003c\/b\u003e Start at the field sensor and verify its waveform. Next, confirm voltage and current at the module terminals. Then check the operating mode, PLC configuration, and program behavior. This sequence helps separate field wiring faults from configuration or application-logic problems.\u003c\/p\u003e\n\u003cp\u003eThe module’s high-speed input function does not by itself identify the root cause of a machine fault. System diagnostics depend on the PLC program, available status information, the connected sensor, and the overall control architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08 | Global PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting a high-speed input module, engineers should compare the shortest valid field pulse with the input module’s detection requirements and the PLC application's response time. A short input response specification is only one part of the timing chain.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eFor high-speed photoelectric sensing:\u003c\/b\u003e Confirm that the sensor produces a pulse of sufficient width and meets the module’s voltage and current thresholds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor production-line counting:\u003c\/b\u003e Evaluate the minimum interval between events as well as pulse width. Confirm that the program can process events at the required rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor interrupt-driven applications:\u003c\/b\u003e Review the interrupt configuration, program execution, and potential event frequency before enabling the function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor replacement projects:\u003c\/b\u003e Match the exact model code, terminal arrangement, input voltage, and required operating mode. Check the existing program before replacing a module with a different input type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor fault investigation:\u003c\/b\u003e Use an oscilloscope or suitable measurement instrument to confirm the actual pulse waveform when intermittent events are difficult to reproduce.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cb\u003eYokogawa F3XH04-3N\u003c\/b\u003e is most appropriate when the control system needs reliable detection of short 24 V DC input pulses. Applications that require pulse accumulation or precise frequency measurement should be checked against the specifications of the complete FA-M3 system.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e09 | Five Professional FAQs\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ1. How can I determine whether the F3XH04-3N is suitable for my sensor?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the sensor’s output type, supply voltage, ON-state voltage and current, OFF-state leakage, and minimum pulse width. The module is designed for 24 V DC inputs, with an operating voltage range of 20.4–26.4 V DC. Confirm that the sensor output meets the module’s switching thresholds under actual load conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ2. Will the module reliably capture pulses generated at a very high repetition rate?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe 50 μs minimum pulse width describes the specified pulse detection capability, but it does not establish a maximum event frequency for every application. Check the pulse period, OFF time, event spacing, PLC processing load, and required counting behavior. Obtain the applicable manufacturer specifications if the application depends on a guaranteed maximum event rate.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ3. What should I check before changing from pulse-capture mode to interrupt mode?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm which function the control program requires and review the existing DIP switch settings. The two functions cannot be used simultaneously. Check the per-point interrupt setup in WideField3 and validate the program response after making any configuration changes.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ4. Is this module a direct replacement for a standard 24 V DC digital input module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNot necessarily. Although it accepts 24 V DC signals, it includes high-speed pulse-capture and interrupt features that may require specific configuration and program logic. Before replacement, verify the FA-M3 system configuration, terminal wiring, input behavior, and application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ5. What details should I provide when requesting a quotation for this module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full model number F3XH04-3N, required quantity, destination country, and any timing or application requirements. If replacing an installed unit, include the controller model, existing module model, and a clear nameplate photo where available. These details help verify the requested configuration and reduce selection errors.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10 | Ordering, Warranty and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eManufacturer:\u003c\/b\u003e Yokogawa\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eModel:\u003c\/b\u003e F3XH04-3N\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSeries:\u003c\/b\u003e FA-M3\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProduct type:\u003c\/b\u003e High-Speed Pulse Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConfiguration:\u003c\/b\u003e 24 V DC, 4 independent input channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e 12 months, subject to the seller’s written warranty terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShipping options:\u003c\/b\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDispatch target:\u003c\/b\u003e 24–48 hours after order confirmation, subject to stock availability and payment clearance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eRequest a quote for Yokogawa F3XH04-3N.\u003c\/b\u003e Include your required quantity, destination, and application details. For replacement orders, provide the existing module model and relevant FA-M3 system information to help confirm compatibility before shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/F3XH04-3N.png?v=1792044330\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67644124266678,"sku":"F3XH04-3N","price":147.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/F3XH04-3N-1.jpg?v=1792044317","url":"https:\/\/www.plcsparehub.com\/products\/f3xh04-3n-yokogawa-fa-m3-pulse-input-module-24v-dc-4-channel","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}