{"product_id":"f3xd64-4f-yokogawa-fa-m3-64-point-dc-input-module","title":"F3XD64-4F Yokogawa FA-M3 64-Point DC Input Module","description":"\u003ch3\u003e\u003cstrong\u003eHigh-Density Architecture \u0026amp; Functional Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eF3XD64-4F\u003c\/span\u003e\u003c\/strong\u003e high-density digital input card provides extensive signal acquisition for complex automation layouts. Designed by \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eYokogawa\u003c\/span\u003e\u003c\/strong\u003e within the robust \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eFA-M3\u003c\/span\u003e\u003c\/strong\u003e controller family, this \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eF3XD64-4F\u003c\/span\u003e\u003c\/strong\u003e module integrates 64 individual 12V DC sinking or sourcing channels into a single compact slot.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eYokogawa\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eF3XD64-4F\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFA-M3 Programmable Controller Platform\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Type \u0026amp; Logic\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDC Voltage (Sink \/ Source Compatible)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Input Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 Points (8 Points per Common Group)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 Volts DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Input Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.1 mA per point at 12V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Voltage Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10.2V to 13.2V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eON-State Thresholds\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0V DC min. \/ 2.6 mA min.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOFF-State Thresholds\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.4V DC max. \/ 1.0 mA max.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSelectable Filter Speeds\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 Steps: 0 µs (Always), 62.5 µs, 250 µs, 1 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSimultaneous ON Ratio\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60% Maximum concurrent active channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 mA (5V DC internal backplane power)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWiring Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDual 40-Pin Flat Cable Connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0°C to 55°C (Storage: -20°C to 75°C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10% to 90% RH (Non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e160 grams (0.35 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Hardware Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChassis Placement:\u003c\/strong\u003e Mounts directly into standard FA-M3 base unit slots without occupying external power loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabling Architecture:\u003c\/strong\u003e Utilizes two 40-pin pre-wired connectors to interface seamlessly with marshalling panels and terminal conversion blocks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommon Grouping:\u003c\/strong\u003e Configured into 8 isolated common blocks to support mixed sensor polarity layouts safely.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eBuilt-in Diagnostic \u0026amp; Filtering Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurable Noise Filtering:\u003c\/strong\u003e Software-selectable sampling intervals (0 µs to 1 ms) suppress transient line chatter in noisy industrial environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Overload Protection:\u003c\/strong\u003e Internal layout manages heat dissipation efficiently while operating under the maximum 60% simultaneous ON constraint.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLogic Status Polling:\u003c\/strong\u003e Base processor continuously monitors bus communication integrity and channel status registers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Insight \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur automation field specialists frequently deploy the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eF3XD64-4F\u003c\/span\u003e\u003c\/strong\u003e unit in high-density discrete sorting systems where cabinet footprint is critically limited. During a recent high-speed conveyor upgrade, technicians noted intermittent bit-flipping caused by high-frequency drive noise. Adjusting the input sampling filter from 0 µs to 250 µs instantly eliminated false triggers while preserving precise optical sensor response times.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Engineering Tip:\u003c\/strong\u003e When wiring 64 channels through the dual 40-pin connectors, always bundle and secure your pre-fabricated ribbon cables away from high-voltage motor lines to prevent electromagnetic coupling.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios \u0026amp; Target Machinery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-density proximity and photoelectric sensor matrix monitoring arrays.\u003c\/li\u003e\n  \u003cli\u003eAutomated warehousing parcel sorting and package diversion lines.\u003c\/li\u003e\n  \u003cli\u003eComplex packaging machinery featuring dense multi-point interlock safety loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSelection \u0026amp; Engineering Buyer's Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that your field device operating voltage strictly matches the 10.2V to 13.2V DC window required by this 12V variant.\u003c\/li\u003e\n  \u003cli\u003eCalculate your active sensor load to ensure no more than 60% of the 64 points remain turned on simultaneously.\u003c\/li\u003e\n  \u003cli\u003eConfirm that your base rack power supply can accommodate the 100 mA internal 5V DC current draw.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eLogistics, Fulfillment \u0026amp; Warranty Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Fully covered by a 12-Month Quality Guarantee.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFulfillment Speed:\u003c\/strong\u003e Fast dispatch processing within 24 to 48 hours.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Couriers:\u003c\/strong\u003e Secure international air freight via FedEx, UPS, and DHL.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackage Inventory:\u003c\/strong\u003e 1 x \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eYokogawa\u003c\/span\u003e\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eF3XD64-4F\u003c\/span\u003e\u003c\/strong\u003e Module, Antistatic Protection, Technical Insertion Leaflet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the F3XD64-4F module handle standard 24V DC sensor inputs directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this model is specifically engineered for a 12V DC rated input voltage range and will not operate correctly with 24V signals.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the 60% simultaneous ON limitation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It prevents excessive internal thermal buildup within the high-density 64-channel circuitry during continuous operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How do I connect external field wires to the dual 40-pin connectors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: You should use compatible 40-pin pre-wired connector cables linked to intermediate terminal conversion blocks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What troubleshooting steps should I take if a whole block of 8 points stops responding?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Check the shared common connection for that specific 8-point group and verify the 12V DC field power supply stability.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How do I choose between the 4 selectable input response filter steps?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Use 0 µs for instantaneous high-speed timing applications, or select up to 1 ms to filter out electrical contact bounce and line noise.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67878526058678,"sku":"F3XD64-4F","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/F3XD64-4F-1.jpg?v=1793173007","url":"https:\/\/www.plcsparehub.com\/products\/f3xd64-4f-yokogawa-fa-m3-64-point-dc-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}