{"product_id":"f3xa16-1n-yokogawa-electric-fa-m3-plc-input-module","title":"F3XA16-1N Yokogawa Electric FA-M3 PLC Input Module","description":"\u003ch3\u003e\u003cstrong\u003eYokogawa F3XA16-1N | FA-M3 16-Point AC Input Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3XA16-1N\u003c\/strong\u003e is a 16-point AC input module for the FA-M3 PLC platform. It receives AC field signals through photocoupler-isolated input circuits, allowing the controller to monitor discrete conditions from industrial equipment.\u003c\/p\u003e\n\u003cp\u003eFor control engineers, the main selection criteria are the field signal voltage, input threshold, response-time setting, common-terminal arrangement, and environmental conditions. Confirm these factors against the actual wiring diagram before installing the module in an existing control system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Signal Acquisition Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnical item\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct series\u003c\/td\u003e\n\u003ctd\u003eFA-M3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eF3XA16-1N\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule type\u003c\/td\u003e\n\u003ctd\u003eAC digital input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput type\u003c\/td\u003e\n\u003ctd\u003eAC voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation method\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input voltage\u003c\/td\u003e\n\u003ctd\u003e100–120 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current\u003c\/td\u003e\n\u003ctd\u003e5.4–6.5 mA per point at 100–120 V AC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage range\u003c\/td\u003e\n\u003ctd\u003e85–132 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON threshold\u003c\/td\u003e\n\u003ctd\u003e80 V AC minimum; 5 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF threshold\u003c\/td\u003e\n\u003ctd\u003e40 V AC maximum; 1 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-to-ON response\u003c\/td\u003e\n\u003ctd\u003eSelectable: 15 ms maximum or 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-to-OFF response\u003c\/td\u003e\n\u003ctd\u003eSelectable: 25 ms maximum or 40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum simultaneous ON ratio\u003c\/td\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput common arrangement\u003c\/td\u003e\n\u003ctd\u003e8 points per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal connection\u003c\/td\u003e\n\u003ctd\u003e18-point terminal block, M3.5 screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt function\u003c\/td\u003e\n\u003ctd\u003eSelectable for each input point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e65 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 180 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Input Thresholds: Distinguish a Valid Signal from an Uncertain State\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInput troubleshooting starts with the actual voltage at the module terminals. The stated operating range is 85–132 V AC, while the specified ON and OFF thresholds define the expected input recognition limits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal ON condition:\u003c\/strong\u003e Verify that the input voltage and available current meet the specified ON requirements under the actual field wiring conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal OFF condition:\u003c\/strong\u003e Check that the residual voltage and leakage current remain within the specified OFF limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUncertain signal condition:\u003c\/strong\u003e Investigate voltage levels between the stated ON and OFF thresholds rather than assuming that every intermediate value produces a predictable state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntermittent input:\u003c\/strong\u003e Measure the terminal voltage during the actual switching event and check for unstable supply, loose wiring, or contact problems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePhotocoupler isolation separates the input sensing circuit from the internal logic interface within the module's specified design. It does not eliminate the need for correct grounding, external protection, or compliance with the system's electrical safety requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Sixteen Inputs, Two Common Groups\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides 16 input points arranged as eight points per common. This grouping affects field wiring, circuit identification, and troubleshooting procedures.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign consideration\u003c\/th\u003e\n\u003cth\u003eEngineering action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon-terminal grouping\u003c\/td\u003e\n\u003ctd\u003eIdentify the applicable common terminal for each group of eight inputs before wiring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField voltage distribution\u003c\/td\u003e\n\u003ctd\u003eVerify the AC source, circuit protection, and return path against the manufacturer's wiring diagram.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal identification\u003c\/td\u003e\n\u003ctd\u003eLabel each input by equipment tag and PLC address to simplify commissioning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput response\u003c\/td\u003e\n\u003ctd\u003eChoose the appropriate response-time setting according to the signal behavior and application requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt assignment\u003c\/td\u003e\n\u003ctd\u003eConfirm the controller program and module configuration before enabling point-specific interrupt behavior.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDo not assume that all 16 points share one common terminal. Follow the module terminal diagram to prevent wiring errors and unintended cross-connections between field circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Response-Time Selection and Interrupt Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe selectable input response settings help engineers match signal acquisition to the characteristics of the connected device. The correct choice depends on the switching behavior, required detection time, and expected electrical noise environment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine status monitoring:\u003c\/strong\u003e Use a response setting compatible with the switching behavior of auxiliary contacts, position switches, and other AC status signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess equipment monitoring:\u003c\/strong\u003e Confirm that the selected response time meets the control sequence's requirements for detecting equipment state changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent-driven logic:\u003c\/strong\u003e Where point-specific interrupts are supported by the system configuration, verify the interrupt assignment and program handling before operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise-sensitive circuits:\u003c\/strong\u003e Investigate transient signals and wiring interference before choosing a faster response setting solely to improve detection speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering caution:\u003c\/strong\u003e Do not interpret the stated input response time as the complete PLC scan or end-to-end application response time. Controller execution, communication, program logic, and field-device behavior also affect the final system response.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Suitable Equipment and Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003cth\u003eExample input signals\u003c\/th\u003e\n\u003cth\u003eSelection focus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial machine control\u003c\/td\u003e\n\u003ctd\u003eAC-powered position switches and auxiliary contacts\u003c\/td\u003e\n\u003ctd\u003eInput threshold and switching response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging lines\u003c\/td\u003e\n\u003ctd\u003eMachine-state and sequence-status signals\u003c\/td\u003e\n\u003ctd\u003eSignal timing and channel identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConveyor systems\u003c\/td\u003e\n\u003ctd\u003eEquipment status contacts and compatible AC field signals\u003c\/td\u003e\n\u003ctd\u003eCommon grouping and wiring integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess skids\u003c\/td\u003e\n\u003ctd\u003eDiscrete status signals from compatible auxiliary equipment\u003c\/td\u003e\n\u003ctd\u003eSupply stability and electrical noise control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtility and facility control panels\u003c\/td\u003e\n\u003ctd\u003eAC status contacts from compatible control circuits\u003c\/td\u003e\n\u003ctd\u003eRated voltage and electrical protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExisting FA-M3 installations\u003c\/td\u003e\n\u003ctd\u003eConfigured AC digital input points\u003c\/td\u003e\n\u003ctd\u003eModule identity, terminal layout, and controller compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eUse this module for compatible AC discrete signals, not for direct measurement of analog voltage, current, temperature, or other continuous process variables. Those applications require the appropriate input module and signal-conditioning arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Field Diagnostics: A Step-by-Step Fault Isolation Method\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen an input does not change state as expected, isolate the problem in a controlled sequence. Compare the field signal, terminal voltage, input recognition, and controller logic before replacing the module.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved symptom\u003c\/th\u003e\n\u003cth\u003ePotential cause\u003c\/th\u003e\n\u003cth\u003eDiagnostic approach\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput remains OFF when the field device activates\u003c\/td\u003e\n\u003ctd\u003eInsufficient voltage, open wiring, incorrect common connection, or a defective field contact\u003c\/td\u003e\n\u003ctd\u003eMeasure AC voltage at the module terminals using approved electrical safety procedures and verify the wiring diagram.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput remains ON after the field device switches OFF\u003c\/td\u003e\n\u003ctd\u003eResidual voltage, wiring cross-connection, a stuck contact, or incorrect circuit identification\u003c\/td\u003e\n\u003ctd\u003eCheck the source circuit and measure the terminal condition in both commanded states.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput changes state intermittently\u003c\/td\u003e\n\u003ctd\u003eLoose terminal, unstable supply, worn contact, or electrical interference\u003c\/td\u003e\n\u003ctd\u003eInspect the connection and monitor the signal during the fault condition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeveral points in one group fail together\u003c\/td\u003e\n\u003ctd\u003eCommon-terminal wiring issue, shared supply problem, or a group-level connection fault\u003c\/td\u003e\n\u003ctd\u003eInspect the relevant common and field supply before testing individual input channels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC status differs from the expected field condition\u003c\/td\u003e\n\u003ctd\u003eInput mapping error, program logic, configuration issue, or an input circuit fault\u003c\/td\u003e\n\u003ctd\u003eCompare the terminal measurement, configured input address, and controller program state.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrief signals are not detected reliably\u003c\/td\u003e\n\u003ctd\u003eResponse-time setting, signal duration, or controller execution timing\u003c\/td\u003e\n\u003ctd\u003eCompare the field signal duration with the configured response time and application processing requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt-driven logic does not execute as expected\u003c\/td\u003e\n\u003ctd\u003eIncorrect interrupt assignment, controller configuration, or program handling\u003c\/td\u003e\n\u003ctd\u003eVerify the point-specific interrupt configuration and test the program under controlled conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance note:\u003c\/strong\u003e The supplied specification does not define a complete LED diagnostic code table. Refer to the applicable FA-M3 hardware documentation for indicator meanings and diagnostic procedures rather than inferring a fault code.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Installation and Environmental Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0 to 55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e −20 to 75°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating humidity:\u003c\/strong\u003e 10–90% RH, non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage humidity:\u003c\/strong\u003e 10–90% RH, non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAtmosphere:\u003c\/strong\u003e Keep the installation free from corrosive gases, flammable gases, and heavy dust.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal connections:\u003c\/strong\u003e Use the specified 18-point M3.5 screw terminal arrangement and follow the manufacturer's wiring instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore installation or maintenance, isolate the relevant AC field circuits and follow the site's lockout\/tagout procedures. Verify the absence of hazardous voltage before touching terminals. Photocoupler isolation is not a substitute for safe isolation practices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor maintenance engineers, the main advantage of the \u003cstrong\u003eF3XA16-1N\u003c\/strong\u003e is its combination of 16 AC input points, photocoupler isolation, selectable response settings, and point-specific interrupt capability within an FA-M3 control system.\u003c\/p\u003e\n\u003cp\u003eWhen selecting a replacement, check the exact model and suffix, the 100–120 V AC input requirement, the two eight-point common groups, the terminal arrangement, and the controller configuration. A module with the same point count may still differ in signal type or electrical characteristics.\u003c\/p\u003e\n\u003cp\u003eFor intermittent input faults, record the field voltage in both ON and OFF states before changing the response-time setting. This helps distinguish a threshold problem from contact degradation, residual voltage, wiring issues, or configuration errors.\u003c\/p\u003e\n\u003cp\u003eGlobal PLC Spare HUB recommends confirming the catalog number and installation requirements before ordering. Providing the existing module label and application details can help reduce the risk of selecting an incompatible spare.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Ordering, Warranty, and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Yokogawa FA-M3 AC digital input module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e F3XA16-1N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's written warranty terms and coverage conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStock status:\u003c\/strong\u003e Confirm availability and dispatch timing when requesting a quotation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Confirm the supplied packaging and any included accessories in the order confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume that terminal blocks, cables, mounting accessories, or other system components are included unless the quotation explicitly lists them.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Professional FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I decide whether the 15 ms or 30 ms OFF-to-ON response setting is appropriate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the minimum signal duration that the application must detect. Compare that duration with the module's documented response settings, then consider controller execution and program handling. Validate the selected setting during commissioning rather than choosing the fastest option without checking signal quality and noise exposure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should I investigate if several input points become unreliable at the same time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the shared field supply, common-terminal wiring, protective devices, and the condition of the circuits feeding those points. If the affected inputs belong to one eight-point common group, prioritize that group's shared connections before assuming multiple channels have failed independently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this module read a 24 V DC sensor or a 4–20 mA transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The specified input type is 100–120 V AC discrete voltage. A 24 V DC sensor requires a compatible DC input interface, while a 4–20 mA transmitter requires an appropriate analog input module. Verify the signal type before ordering a replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What information is most useful when identifying a replacement for an installed module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete catalog number and suffix, clear photos of the nameplate and terminal wiring, the FA-M3 system configuration, and the field signal voltage. These details help confirm electrical compatibility, common-terminal arrangement, and installation requirements. Do not rely on the family name or input count alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How should I evaluate a module that appears faulty but passes basic voltage checks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the signal at the module terminal during the actual switching event, verify the input address and controller logic, and review the selected response time. If the signal remains within specification but the input state is incorrect, follow the manufacturer's diagnostic procedure and test the module under controlled conditions before arranging replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest a Quote for F3XA16-1N\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eLooking for the \u003cstrong\u003eYokogawa F3XA16-1N FA-M3 AC input module\u003c\/strong\u003e for maintenance or system integration? Send the model number, quantity, destination, and existing system details to request a quotation and confirm availability, warranty, and shipping arrangements.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/F3XA08-1N_F3XA08-2N_F3XA16-1N_882148f4-39f8-44f3-8a2b-3b11148c4501.png?v=1792046150\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":67644155363510,"sku":"F3XA16-1N","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/F3XA16-1N-1.jpg?v=1792046136","url":"https:\/\/www.plcsparehub.com\/products\/f3xa16-1n-yokogawa-electric-fa-m3-plc-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}