{"product_id":"f-8628x-hima-profibus-dp-slave-module-original-communication","title":"F 8628X HIMA Profibus DP Slave Module | Original Communication","description":"\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cspan style=\"color: #d9534f;\"\u003eF 8628X\u003c\/span\u003e represents a critical upgrade for HIMA H41q and H51q safety systems.\u003c\/li\u003e\n\u003cli\u003eUnlike the legacy F 8628, the \u003cspan style=\"color: #d9534f;\"\u003eF 8628X\u003c\/span\u003e introduces high-speed ELOP II programming via Ethernet.\u003c\/li\u003e\n\u003cli\u003eThis module serves as a dual-purpose interface, bridging Profibus DP Slave protocols with 100Base-T Ethernet connectivity.\u003c\/li\u003e\n\u003cli\u003eIt is engineered for high-availability environments where safety-critical CPU programming requires modern network infrastructure.\u003c\/li\u003e\n\u003cli\u003eThe \u003cspan style=\"color: #d9534f;\"\u003eF 8628X\u003c\/span\u003e ensures long-term viability for existing HIMA safety racks by modernizing the communication backbone.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #d9534f;\"\u003eHIMA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #d9534f;\"\u003eF 8628X\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cspan style=\"color: #d9534f;\"\u003eH41q \/ H51q Systems\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol 1:\u003c\/strong\u003e Profibus DP Slave (EN 50170)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol 2:\u003c\/strong\u003e Ethernet 100Base-T (IEEE 802.3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e ELOP II via Ethernet (Version 4.1+)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e 9-pole SUB-D \u0026amp; RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e 19-inch module, 3 HU (Height Units), 4 WU (Width Units)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 61131-2, EN 61000-6, EN 50081-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 3x 44.45 mm height, 4x 5.08 mm width\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Target Equipment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for safe CPUs: \u003cspan style=\"color: #d9534f;\"\u003eF 8650X\u003c\/span\u003e and \u003cspan style=\"color: #d9534f;\"\u003eF 8652X\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eFully compatible with non-safe CPUs: \u003cspan style=\"color: #d9534f;\"\u003eF 8651X\u003c\/span\u003e and \u003cspan style=\"color: #d9534f;\"\u003eF 8653X\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eBackward compatible with HIMA 19-inch subracks supporting 3HU modules.\u003c\/li\u003e\n\u003cli\u003eIntegrates with ELOP II engineering workstations via standard TCP\/IP networks.\u003c\/li\u003e\n\u003cli\u003eWorks alongside existing F 8627 and F 8628 modules within the same portfolio.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdvanced Diagnostics \u0026amp; Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Programming:\u003c\/strong\u003e Enables CPU logic updates over Ethernet, reducing the need for local serial connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Monitoring:\u003c\/strong\u003e Profibus DP status can be verified via the SUB-D interface diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Compliance:\u003c\/strong\u003e Meets EN 50082-2 for electromagnetic compatibility in harsh industrial zones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Integration:\u003c\/strong\u003e Designed to maintain the SIL requirements of the associated HIMA safety CPUs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Identification:\u003c\/strong\u003e Standard HIMA 4WU width allows for precise slot alignment and cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown (ESD) systems in petrochemical plants.\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS) requiring Profibus integration.\u003c\/li\u003e\n\u003cli\u003eFire and Gas (F\u0026amp;G) detection networks utilizing Ethernet backbones.\u003c\/li\u003e\n\u003cli\u003eCentralized safety monitoring in power generation facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Period:\u003c\/strong\u003e 12 Months comprehensive industrial warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Carrier:\u003c\/strong\u003e Priority express via FedEx, DHL, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Time:\u003c\/strong\u003e Ships within 24-48 hours from current stock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Original HIMA-certified protective anti-static packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSelection \u0026amp; Expert Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure your ELOP II software is Version 4.1 or higher to utilize the Ethernet programming feature of the \u003cspan style=\"color: #d9534f;\"\u003eF 8628X\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eIf your application only requires Profibus without Ethernet programming, the legacy F 8628 remains a valid option.\u003c\/li\u003e\n\u003cli\u003eVerify the width units (WU) available in your rack; the \u003cspan style=\"color: #d9534f;\"\u003eF 8628X\u003c\/span\u003e requires 4 WU (approx. 20.32 mm).\u003c\/li\u003e\n\u003cli\u003eAlways use shielded RJ45 connectors to maintain the EMC standards specified for HIMA systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the main advantage of the F 8628X over the standard F 8628?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe \u003cspan style=\"color: #d9534f;\"\u003eF 8628X\u003c\/span\u003e allows engineers to program HIMA CPUs via Ethernet, significantly increasing data transfer speeds.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDoes the F 8628X support safe communication between different PLC racks?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe module operates as a Profibus DP Slave; safe peer-to-peer communication usually depends on the safety layer used.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan I use this module with older ELOP II versions?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eEthernet programming specifically requires ELOP II V. 4.1 or later; older versions will not recognize the Ethernet path.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIs the Ethernet port used for Profinet communication?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eNo, the Ethernet port on the \u003cspan style=\"color: #d9534f;\"\u003eF 8628X\u003c\/span\u003e is primarily for programming; the fieldbus protocol is Profibus DP.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat happens to my existing F 8628 modules if I add an F 8628X?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThey can coexist in the same system; the \u003cspan style=\"color: #d9534f;\"\u003eF 8628X\u003c\/span\u003e provides an upgraded feature set for the newer X-series CPUs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45013998305462,"sku":"F8628X","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/F8628X.jpg?v=1775122310","url":"https:\/\/www.plcsparehub.com\/products\/f-8628x-hima-profibus-dp-slave-module-original-communication","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}