{"product_id":"ec402-50-yokogawa-esb-bus-coupler-ec402-50-original-module","title":"EC402-50 Yokogawa ESB Bus Coupler | EC402-50 Original Module","description":"\u003ch3\u003e\u003cb\u003eYokogawa EC402-50 ESB Bus Coupler Module\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1565c0;\"\u003eYokogawa EC402-50\u003c\/strong\u003e is a two-port ESB Bus Coupler Module designed for Yokogawa N-IO\/FIO systems. It provides the ESB bus master interface function and manages communication between the controller-side bus and connected I\/O modules.\u003c\/p\u003e\n\u003cp\u003eThe module supports up to nine connectable units on each side of the ESB bus. It provides a transmission speed of 128 Mbps for I\/O module data and supports a maximum transmission distance of 10 meters per side.\u003c\/p\u003e\n\u003cp\u003eEC402-50 is the standard, non-explosion-protected, basic-type version of the EC402 bus coupler family. It is intended for control system configurations that require reliable ESB communication and a clearly defined module installation arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e01 | Model Identification \u0026amp; Configuration Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEC402\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eESB Bus Coupler Module, two-port type for N-IO\/FIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix 1\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard type without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix 2\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #1565c0;\"\u003eEC402-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, non-explosion-protected, basic two-port ESB Bus Coupler Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration hierarchy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEC402\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eProduct family: ESB Bus Coupler Module\u003c\/li\u003e\n\u003cli\u003eInterface: ESB bus master\u003c\/li\u003e\n\u003cli\u003ePort configuration: Two-port\u003c\/li\u003e\n\u003cli\u003eApplication: N-IO\/FIO system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-5\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eStandard hardware type\u003c\/li\u003e\n\u003cli\u003eNo explosion protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eBasic configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor ordering and replacement, verify the complete suffix. Do not select a coupler based only on the EC402 base model.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e02 | ESB Communication Performance\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eEC402-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eESB Bus Coupler Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Function\u003c\/td\u003e\n\u003ctd\u003eESB bus master interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003e2 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e128 Mbps for I\/O module data transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectable Units\u003c\/td\u003e\n\u003ctd\u003eMaximum 9 units per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpper-side Transmission Distance\u003c\/td\u003e\n\u003ctd\u003eMaximum 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower-side Transmission Distance\u003c\/td\u003e\n\u003ctd\u003eMaximum 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Transmission Distance\u003c\/td\u003e\n\u003ctd\u003eMaximum 20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e03 | ESB Bus Topology and Installation Rules\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe EC402-50 installation position depends on whether the ESB bus uses a non-redundant or dual-redundant configuration. The controller slot arrangement must follow the applicable Yokogawa system configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eESB Configuration\u003c\/th\u003e\n\u003cth\u003e7th Slot\u003c\/th\u003e\n\u003cth\u003e8th Slot\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-redundant\u003c\/td\u003e\n\u003ctd\u003eEC402-50\u003c\/td\u003e\n\u003ctd\u003eDummy module required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003ctd\u003eESB Bus Coupler Module\u003c\/td\u003e\n\u003ctd\u003eESB Bus Coupler Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable controller models:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAFV30S \/ AFV30D\u003c\/li\u003e\n\u003cli\u003eAFV40S \/ AFV40D\u003c\/li\u003e\n\u003cli\u003eA2FV50S \/ A2FV50D\u003c\/li\u003e\n\u003cli\u003eA2FV70S \/ A2FV70D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNon-redundant configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the ESB Bus Coupler Module in the 7th slot.\u003c\/li\u003e\n\u003cli\u003eCover the 8th slot with a dummy module.\u003c\/li\u003e\n\u003cli\u003eConfirm that the controller model supports the selected arrangement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDual-redundant configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall ESB Bus Coupler Modules in both the 7th and 8th slots.\u003c\/li\u003e\n\u003cli\u003eVerify that both modules and their associated bus connections are correctly configured.\u003c\/li\u003e\n\u003cli\u003eCheck the controller hardware configuration before system startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIncorrect slot allocation can prevent the intended ESB bus configuration from operating correctly. Always check the system hardware manual and cabinet drawings before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04 | Engineering Considerations for System Integration\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign Check\u003c\/th\u003e\n\u003cth\u003eEngineering Recommendation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit count\u003c\/td\u003e\n\u003ctd\u003eKeep the connected unit count within nine units on each side.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable distance\u003c\/td\u003e\n\u003ctd\u003eKeep each side within 10 m and the total within 20 m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower budget\u003c\/td\u003e\n\u003ctd\u003eAllow for the module's 0.5 A current consumption in the system power calculation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot allocation\u003c\/td\u003e\n\u003ctd\u003eUse the 7th and 8th slots according to the redundancy design.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion protection\u003c\/td\u003e\n\u003ctd\u003eEC402-50 is the standard type without explosion protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement selection\u003c\/td\u003e\n\u003ctd\u003eMatch the complete part number and hardware configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e05 | Typical Industrial Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eYokogawa N-IO systems:\u003c\/strong\u003e Provides the ESB master interface for connected I\/O units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFIO system integration:\u003c\/strong\u003e Supports ESB communication between the controller and field I\/O architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed process control:\u003c\/strong\u003e Connects multiple I\/O units within the specified bus topology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant control architectures:\u003c\/strong\u003e Supports dual-coupler installation in systems designed for dual-redundant ESB communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl system maintenance:\u003c\/strong\u003e Serves as a replacement component for compatible installed ESB bus coupler configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e06 | Installation, Commissioning and Maintenance\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the model:\u003c\/strong\u003e Check the complete EC402-50 part number and suffix configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the installation slot:\u003c\/strong\u003e Verify the controller model and the required 7th\/8th slot arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck bus topology:\u003c\/strong\u003e Confirm the number of connected units and the cable distance on both sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview power requirements:\u003c\/strong\u003e Include the 0.5 A current consumption in the cabinet power budget.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify system configuration:\u003c\/strong\u003e Check hardware settings and the intended redundancy arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerform communication checks:\u003c\/strong\u003e Confirm that the controller recognizes the connected I\/O units after startup.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eBefore replacement, follow the site's approved isolation and maintenance procedures. Use the Yokogawa hardware installation manual for module handling and commissioning details.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e07 | Product Supply, Warranty and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEC402-50\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eEC402 ESB Bus Coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTwo-Port ESB Bus Coupler Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Condition\u003c\/td\u003e\n\u003ctd\u003eNew \u0026amp; Original in Factory Packing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eFactory Warranty: 12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Options\u003c\/td\u003e\n\u003ctd\u003eFedEx, UPS, DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eContact Global PLC Spare HUB for EC402-50 pricing, stock status, and delivery information. Provide your controller model and ESB redundancy arrangement to help confirm product compatibility before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08 | Frequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I choose between a single EC402-50 and a dual-module arrangement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with the controller's ESB bus design. A non-redundant arrangement uses the 7th slot for the coupler and requires a dummy module in the 8th slot. A dual-redundant arrangement uses coupler modules in both positions. The selection should follow the approved system architecture, not simply the number of available slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should I investigate if some I\/O units are not detected after installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the coupler's slot position, ESB cable connections, connected unit count, and cable length on each side. Then compare the physical installation with the controller hardware configuration. A mismatch between the configured topology and the actual wiring is a useful starting point for troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can I extend the ESB cable beyond 10 meters on one side if the total remains below 20 meters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The stated limit is 10 meters for each side, with a maximum combined distance of 20 meters. Meeting the total distance limit does not compensate for exceeding an individual side's limit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What details should I check before ordering a replacement for an existing coupler?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the full part number, including -50, the controller model, the installed slot position, and whether the system uses non-redundant or dual-redundant ESB communication. Also compare the nameplate and existing hardware configuration. These checks reduce the risk of ordering a similar-looking but incompatible version.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Is EC402-50 suitable for installation in an explosion-protected area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEC402-50 is specified as a standard type without explosion protection. Do not use this suffix as evidence of hazardous-area suitability. Review the site's area classification and the relevant Yokogawa certification documentation before selecting equipment for a hazardous location.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":68128905068726,"sku":"EC402-50","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/EC402-502.jpg?v=1795420705","url":"https:\/\/www.plcsparehub.com\/products\/ec402-50-yokogawa-esb-bus-coupler-ec402-50-original-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}