{"product_id":"ds200rtbag3agc-ge-ex2000-relay-terminal-board-mark-v-module","title":"DS200RTBAG3AGC GE EX2000 Relay Terminal Board | Mark V Module","description":"\u003ch3\u003eTechnical Architecture \u0026amp; Functional Scope\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200RTBAG3AGC\u003c\/strong\u003e\u003c\/span\u003e is a high-density Relay Terminal Board (RTBA) engineered for the \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eGE EX2000\u003c\/strong\u003e\u003c\/span\u003e and \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eMark V\u003c\/strong\u003e\u003c\/span\u003e control environments. Serving as a supplemental I\/O interface, this board expands cabinet capability by providing ten discrete relay points. It facilitates remote control operations via LAN I\/O interaction or direct user command, ensuring robust switching logic for industrial exciters and turbine drives.\u003c\/p\u003e\n\n\u003ch3\u003eConfiguration \u0026amp; Relay Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eGeneral Electric (GE)\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200RTBAG3AGC\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e EX2000 \/ Mark V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Bank 1 (K20-K26):\u003c\/strong\u003e 7 x DPDT (2 Form C contacts each, 10A rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Bank 2 (K27-K29):\u003c\/strong\u003e 3 x 4PDT (4 Form C contacts each, 1A rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil Voltage:\u003c\/strong\u003e 110 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e 130 VAC Metal Oxide Varistor (MOV) per I\/O channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Field Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Use provided connector levers for CP-series plugs; avoid pulling ribbon cables by their harness to prevent internal wire breakage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Swap:\u003c\/strong\u003e The modular design allows hot-swappable replacement (post-power isolation). Depress the retaining clip top to disengage the relay housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Termination:\u003c\/strong\u003e When replacing the entire board, verify all terminal screws are torqued to ensure consistent contact resistance across the 10-point array.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Settings:\u003c\/strong\u003e Always verify that jumper positions on the replacement board mirror the legacy unit to prevent logic errors in the exciter control sequence.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200RTBAG3AGC\u003c\/strong\u003e\u003c\/span\u003e is the backbone of secondary switching in legacy turbine cabinets. Our engineering team notes that this board is particularly sensitive to voltage transients; the onboard MOVs are the first line of defense. If you notice localized clicking or irregular contact closure, it is often a sign that the MOV has reached its suppression cycle limit and the entire board requires a health assessment.\u003c\/p\u003e\n\n\u003ch3\u003eProfessional FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I interchange DPDT and 4PDT relays on this board?\u003c\/strong\u003e\u003cbr\u003e\nA: No. The socket pin-outs are physically indexed to match specific relay types; forced installation will damage the PCB trace or relay base.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How does the LAN I\/O Terminal Board interface with these relays?\u003c\/strong\u003e\u003cbr\u003e\nA: The LAN board issues command signals to the RTBA pilot relays, which then actuate the high-current DPDT\/4PDT contacts for external device control.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the 130 VAC MOV protection sufficient for all inductive loads?\u003c\/strong\u003e\u003cbr\u003e\nA: It provides excellent suppression for standard pilot duty; however, for highly inductive DC solenoids, we recommend external arc suppression diodes.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What should I prioritize during the selection\/replacement process?\u003c\/strong\u003e\u003cbr\u003e\nA: Prioritize the hardware revision level and ensure the system voltage matches your cabinet requirements (240-700V range) to avoid potential coil burnout.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Are the CPH\/CPN terminals polarity-sensitive?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. CPH provides the positive (hot) control power, while CPN is the negative return. Incorrect polarity will result in a failure of the relay coil to energize.\u003c\/p\u003e\n\n\u003ch3\u003eLogistics \u0026amp; Quality Commitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpedited Shipping:\u003c\/strong\u003e Secure processing and dispatch within 24-48 hours via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Assurance:\u003c\/strong\u003e Every \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200RTBAG3AGC\u003c\/strong\u003e\u003c\/span\u003e includes a 12-month comprehensive quality warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability:\u003c\/strong\u003e Each card undergoes standardized testing to ensure relay contact integrity and MOV clamping performance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45186986410166,"sku":"DS200RTBAG3AGC","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DS200RTBAG3AGC.jpg?v=1781507003","url":"https:\/\/www.plcsparehub.com\/products\/ds200rtbag3agc-ge-ex2000-relay-terminal-board-mark-v-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}