{"product_id":"ds200rtbag1ahc-ge-ex2000-relay-terminal-board-genuine-stock","title":"DS200RTBAG1AHC GE EX2000 Relay Terminal Board Genuine Stock","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #003366;\"\u003eDS200RTBAG1AHC\u003c\/span\u003e\u003c\/strong\u003e stands as a robust, industrial-grade relay terminal board manufactured by General Electric for the Speedtronic EX2000 excitation system line.\u003c\/li\u003e\n    \u003cli\u003eThis surface-mount technology (\u003cstrong\u003e\u003cspan style=\"color: #003366;\"\u003eRTBA\u003c\/span\u003e\u003c\/strong\u003e) hardware option mounts directly into the drive or exciter cabinet enclosure.\u003c\/li\u003e\n    \u003cli\u003eIt acts as an auxiliary control interface, driving heavy switching matrices via pilot signals originating from local or remote LAN Input\/Output Terminal Boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e General Electric (GE)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #003366;\"\u003eDS200RTBAG1AHC\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSystem Series:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #003366;\"\u003eEX2000 Excitation\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Relay Terminal Board (\u003cstrong\u003e\u003cspan style=\"color: #003366;\"\u003eRTBA\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCircuit Assembly Technology:\u003c\/strong\u003e High-density surface-mount\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTotal Onboard Relays:\u003c\/strong\u003e 10 heavy-duty isolation relays\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eForm C (DPDT) Contacts:\u003c\/strong\u003e 7 independent channels (Double-Pole Double-Throw configuration)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eForm C (4PDT) Contacts:\u003c\/strong\u003e 3 complex channels (Quad-Pole Double-Throw configuration)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMain I\/O Interface:\u003c\/strong\u003e 16-pin RPL connector assembly \u0026amp; 2-pin OPTPL connector port\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eControl Power Distribution:\u003c\/strong\u003e Dual CPH (Hot\/Positive) and CPN (Negative) stab connectors\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAuxiliary Circuit Ports:\u003c\/strong\u003e C1PL to C5PL and Y9PL to Y37PL connection plugs\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHardware Configuration:\u003c\/strong\u003e Berg-type manual jumper blocks (JP nomenclature sequence)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOperational Environment Limits:\u003c\/strong\u003e -30 °C minimum to +65 °C maximum ambient exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Hardware Topology\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eThe physical layout of the \u003cstrong\u003e\u003cspan style=\"color: #003366;\"\u003eDS200RTBAG1AHC\u003c\/span\u003e\u003c\/strong\u003e ensures clean trace separation between high-voltage relay contacts and low-voltage control signals.\u003c\/li\u003e\n    \u003cli\u003eInterface signals passing through the 16-pin RPL bus are jumper-selectable, allowing plants to alter signal behavior without altering core field wiring.\u003c\/li\u003e\n    \u003cli\u003ePluggable sub-circuits and auxiliary relay coils K27 through K29 are accessed via the dedicated C1PL-C5PL and Y9PL-Y37PL pinning blocks for localized expansion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDevice Compatibility \u0026amp; Target Equipment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #003366;\"\u003eEX2000 Speedtronic\u003c\/span\u003e\u003c\/strong\u003e generator excitation cabinet systems\u003c\/li\u003e\n    \u003cli\u003eLarge-scale industrial AC and DC drive motor controllers\u003c\/li\u003e\n    \u003cli\u003eGE synchronized control systems utilizing LTB (LAN I\/O Terminal Board) infrastructure\u003c\/li\u003e\n    \u003cli\u003eHigh-current control loop panels demanding mechanical dry-contact separation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; System Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eVisual tracking of relay logic sequences via dual-contact mechanical position feedback loops.\u003c\/li\u003e\n    \u003cli\u003eIsolated stab points allow technicians to break loop power quickly for line grounding diagnostics.\u003c\/li\u003e\n    \u003cli\u003eHardware-level configuration via fixed Berg jumpers eliminates software corruption or memory loss risks during power drops.\u003c\/li\u003e\n    \u003cli\u003eComplete physical air-gap separation across the 4PDT circuits prevents cross-phase short circuits during catastrophic field failures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTarget Field Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eDistributing interlock pilot signals across synchronous motor starters\u003c\/li\u003e\n    \u003cli\u003eManaging multi-point trip alarm matrices inside heavy drive assemblies\u003c\/li\u003e\n    \u003cli\u003eSourcing auxiliary isolated contact states back to central control room DCS panels\u003c\/li\u003e\n    \u003cli\u003eMultiplexing automated process signals across local exciter cabinet elements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommissioning \u0026amp; Installation Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eVerify the specific revision matrix (A, H, C) matches your controller documentation before mounting.\u003c\/li\u003e\n    \u003cli\u003eCross-check factory Berg jumper settings against the original schematic sheets found inside the drive enclosure pocket.\u003c\/li\u003e\n    \u003cli\u003eTerminate CPH and CPN stab connectors firmly to ensure consistent loop control power distribution.\u003c\/li\u003e\n    \u003cli\u003eEnsure adequate ventilation clearance to maintain ambient air temperatures well below the 65 °C ceiling limit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eFrom a technical maintenance standpoint, the \u003cstrong\u003e\u003cspan style=\"color: #003366;\"\u003eGE DS200RTBAG1AHC\u003c\/span\u003e\u003c\/strong\u003e is built for extreme duty-cycle reliability.\u003c\/li\u003e\n    \u003cli\u003eIncorporating a mix of DPDT and 4PDT Form C relays on a single surface-mount board reduces the footprint of mechanical relay trees inside older control cabinets.\u003c\/li\u003e\n    \u003cli\u003eBecause the control power inputs (CPH\/CPN) are entirely jumper-selectable, engineering teams can seamlessly isolate specific relay groups during live troubleshooting without disabling the primary EX2000 excitation framework.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProcurement \u0026amp; Express Logistics Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBox Inclusions:\u003c\/strong\u003e One \u003cstrong\u003e\u003cspan style=\"color: #003366;\"\u003eDS200RTBAG1AHC\u003c\/span\u003e\u003c\/strong\u003e relay terminal module sealed in static-shielding material.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty Support:\u003c\/strong\u003e 12-month complete operational warranty coverage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShipping Network Services:\u003c\/strong\u003e Fast express shipping via FedEx, UPS, and DHL couriers.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarehouse Processing:\u003c\/strong\u003e Inventory units are prepared and dispatched within 24 to 48 hours of order processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Buying Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eCheck the full alphanumeric revision code (G1AHC) to ensure exact compatibility with older G1 parent layouts.\u003c\/li\u003e\n    \u003cli\u003eAudit your cabinet schematic to verify whether your application relies on the 4PDT relay banks (K27-K29).\u003c\/li\u003e\n    \u003cli\u003eRetain the factory data sheets shipped with the board to trace out customized Berg jumper settings during physical commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ch3\u003eWhat is the specific functional difference between the DPDT and 4PDT relays on this board?\u003c\/h3\u003e\n\u003cp\u003eThe seven DPDT relays handle standard dual-path electrical switching, whereas the three 4PDT relays switch four independent circuits simultaneously, allowing for complex multi-wire interlock controls.\u003c\/p\u003e\n\n\u003ch3\u003eHow do the CPH and CPN stab connectors change board power distribution?\u003c\/h3\u003e\n\u003cp\u003eThese specialized terminal stabs route hot and negative control power directly to the pluggable circuits; their behavior is fully customizable depending on your local manual Berg jumper placement.\u003c\/p\u003e\n\n\u003ch3\u003eAre the Berg-type hardware jumpers pre-set from the factory for standard applications?\u003c\/h3\u003e\n\u003cp\u003eYes, default configurations are applied at the factory. However, any site-specific adjustments must be matched to the configuration logs located inside your specific exciter cabinet door pocket.\u003c\/p\u003e\n\n\u003ch3\u003eCan this board interface directly with control boards other than the LTBA module?\u003c\/h3\u003e\n\u003cp\u003eThe RPL and OPTPL connection points are engineered exclusively to sync with the LAN I\/O Terminal Board architecture for reliable signal execution.\u003c\/p\u003e\n\n\u003ch3\u003eWhy does this module employ surface-mount technology instead of through-hole assembly?\u003c\/h3\u003e\n\u003cp\u003eSurface-mount design increases trace density and resistance to mechanical vibration, preventing contact fractures in harsh turbine and drive bay operational environments.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45205661188278,"sku":"DS200RTBAG1AHC","price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DS200RTBAG1AHC.jpg?v=1782109594","url":"https:\/\/www.plcsparehub.com\/products\/ds200rtbag1ahc-ge-ex2000-relay-terminal-board-genuine-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}