{"product_id":"ds200lppag1aaa-ge-speedtronic-mark-v-protection-board","title":"DS200LPPAG1AAA GE Speedtronic Mark V Protection Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200LPPAG1AAA\u003c\/strong\u003e\u003c\/span\u003e serves as a critical Line Protection Panel Board within the GE Mark V Turbine Control System. It integrates advanced Speedtronic control technology to safeguard complex industrial electrical architectures. This board monitors high-voltage input channels to detect faults, surges, or overcurrent conditions instantly. It ensures personnel safety and protects vital turbine assets from electrical instability.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e General Electric (GE)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark V Turbine Control System\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200LPPAG1AAA\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Line Protection Panel Board\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 230 to 600 VAC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 125 V dc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 12\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 28 V dc\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 40°C to 85°C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e 33.0 cm x 17.8 cm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Chassis Mount\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTechnology:\u003c\/strong\u003e High-density Surface Mount\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Designed for high-heat, industrial turbine environments\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInterference Resistance:\u003c\/strong\u003e Integrated shielding against electromagnetic interference\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation and Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eThe \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200LPPAG1AAA\u003c\/strong\u003e\u003c\/span\u003e mounts directly onto existing drive standoffs.\u003c\/li\u003e\n    \u003cli\u003eSignal wires originate from the primary component for streamlined integration.\u003c\/li\u003e\n    \u003cli\u003eOnboard diagnostic tools allow for immediate system health assessments.\u003c\/li\u003e\n    \u003cli\u003eAccess diagnostics directly through the control panel menu interface.\u003c\/li\u003e\n    \u003cli\u003eDownload detailed reports to a laptop via serial connection for baseline comparisons.\u003c\/li\u003e\n    \u003cli\u003eOnboard jumpers (JP1-JP7) enable specific configuration adjustments for filter and sensing functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility and Applications\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200LPPAG1AAA\u003c\/strong\u003e\u003c\/span\u003e is fully compatible with the GE Mark V Speedtronic series. It acts as the primary defense mechanism in gas turbine control environments. It effectively manages surge suppression, ground fault detection, and SCR ripple filtering. This module is essential for applications requiring rigorous power quality monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering and Logistics\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e Standard industrial compliance\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200LPPAG1AAA\u003c\/strong\u003e\u003c\/span\u003e board and essential documentation\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e Orders ship via FedEx, UPS, or DHL\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLead Time:\u003c\/strong\u003e 24-48 hours processing for in-stock items\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Full 12-month quality assurance guarantee\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eOur engineering team identifies the \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200LPPAG1AAA\u003c\/strong\u003e\u003c\/span\u003e as a mission-critical component for maintaining signal integrity in Mark V systems. Its ability to filter SCR ripple and detect blown fuses via JP1-JP3 jumpers makes it superior to generic protection relays. We recommend this board for high-load turbine environments where electrical noise is a constant operational factor.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHow do I verify the health of my \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200LPPAG1AAA\u003c\/strong\u003e\u003c\/span\u003e board?\u003c\/strong\u003e\u003cbr\u003eUse the integrated diagnostic menu on the turbine control panel to generate a status report. You can then export this data for comparative analysis.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat is the function of the JP6 jumper?\u003c\/strong\u003e\u003cbr\u003eThe JP6 jumper specifically manages the SCR ripple filter settings to maintain clean signal processing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDo I need specialized software to configure this board?\u003c\/strong\u003e\u003cbr\u003eNo, configuration is managed through the drive's native diagnostic interface and physical jumper adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBuying Guide\u003c\/h3\u003e\n\u003cp\u003eEnsure your system requires the \u003cspan style=\"color: #d32f2f;\"\u003e\u003cstrong\u003eDS200LPPAG1AAA\u003c\/strong\u003e\u003c\/span\u003e specific revision level before purchase. Verify the input voltage range matches your existing control cabinet specs (230-600 VAC). Always review your current diagnostic logs to confirm the fault resides within the protection board before replacing.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45186973565110,"sku":"DS200LPPAG1AAA","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DS200LPPAG1AAA.jpg?v=1781506083","url":"https:\/\/www.plcsparehub.com\/products\/ds200lppag1aaa-ge-speedtronic-mark-v-protection-board","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}