{"product_id":"do880-3bse028602r1-abb-s800-digital-output-module-16-channel-sil3","title":"DO880 3BSE028602R1 ABB S800 Digital Output Module | 16-Channel SIL3","description":"\u003ch3\u003eDO880 Executive Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO880\u003c\/strong\u003e\u003c\/span\u003e (Article Number: \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3BSE028602R1\u003c\/strong\u003e\u003c\/span\u003e) is an advanced 16-channel, 24 V d.c. digital output module designed for high-integrity single or redundant control architectures within the ABB S800 I\/O platform. Each channel supplies a continuous output current of up to 0.5 A, featuring built-in short-circuit current limiting and advanced over-temperature protection. Engineered with a high-side driver configuration, inductive load suppression, and rigorous optical isolation from the Modulebus, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO880\u003c\/strong\u003e\u003c\/span\u003e ensures fault-tolerant operation for critical safety instrumented systems requiring SIL3 certification per IEC 61508.\u003c\/p\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: When designing safety-critical emergency shutdown loops using the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO880\u003c\/strong\u003e\u003c\/span\u003e module, control engineers must verify that terminal unit compatibility aligns with field wiring demands. In a recent offshore platform migration project, pairing the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO880\u003c\/strong\u003e\u003c\/span\u003e unit with appropriate TU810 or TU830 mounting units eliminated common-mode transient trips while preserving loop monitoring thresholds for open-load fault detection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Specifications \u0026amp; Technical Parameters\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eABB\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSeries: \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/s800-i-o\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eS800 I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eModule Model \/ Type: \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO880\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003ePart Number: \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3BSE028602R1\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eChannel Capacity: 16 channels, current sourcing\u003c\/li\u003e\n\u003cli\u003eNominal Voltage: 24 V d.c. (Operating range: 19.2 to 32 V d.c.)\u003c\/li\u003e\n\u003cli\u003eMax Continuous Current: 0.5 A per channel\u003c\/li\u003e\n\u003cli\u003eIsolation Architecture: Group-wise isolated from ground (50 V rated insulation voltage, 500 V a.c. dielectric test)\u003c\/li\u003e\n\u003cli\u003ePower Dissipation: 5.6 W total at full load\u003c\/li\u003e\n\u003cli\u003ePhysical Dimensions: Width 45 mm, Depth 102 mm (111 mm with connector), Height 119 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 0.20 kg (0.44 lbs.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironmental Metric\u003c\/th\u003e\n\u003cth\u003eOperational Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to +55 °C (+32 °F to +131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +70 °C (-40 °F to +158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 Class G3 resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Certifications\u003c\/td\u003e\n\u003ctd\u003eC1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eSystem Compatibility \u0026amp; Hardware Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKeying Code: FE\u003c\/li\u003e\n\u003cli\u003eCompatible Terminal Units (MTUs): TU810, TU810V1, TU812, TU814, TU830, TU833, TU842, TU843, TU852.\u003c\/li\u003e\n\u003cli\u003eMaximum Field Cable Length: Up to 600 meters (656 yards) total wire run.\u003c\/li\u003e\n\u003cli\u003eCabinet Mounting: Standard DIN rail or compact S800 base plates (note vertical mounting ambient derating limits to 40 °C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eAdvanced Diagnostics \u0026amp; Fault Detection Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStatus Indicators: Dedicated front-panel LEDs for Fault (F), Run (R), Warning (W), and individual channel status\/error tracking for channels 1 through 16.\u003c\/li\u003e\n\u003cli\u003eLoop Supervision: Configurable loop resistance monitoring from 50 ohms to 2 kilohms to detect open circuits and shorted load conditions.\u003c\/li\u003e\n\u003cli\u003eNon-Pulsing Diagnostics: Evaluates output switches for integrity anomalies without generating unwanted test pulses on active field outputs.\u003c\/li\u003e\n\u003cli\u003eDegraded Mode: Supports operational continuity for normally energized channels starting from product revision PR:G.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD) in oil and gas refineries.\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS) requiring SIL3 loop compliance.\u003c\/li\u003e\n\u003cli\u003eTurbine control and compressor safety interlocks in chemical processing plants.\u003c\/li\u003e\n\u003cli\u003eHigh-availability redundant actuator control hubs in power generation infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFulfillment, Logistics, and Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGlobal Shipping Carriers: Rapid and secure dispatch via \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eFedex, UPS, DHL\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eProcessing Window: Guaranteed dispatch within 24-48 hours for standard catalog inventory.\u003c\/li\u003e\n\u003cli\u003eProtective Packaging: Industrial-grade anti-static shielding and custom foam enclosure to prevent transit damage.\u003c\/li\u003e\n\u003cli\u003eWarranty Coverage: Backed by a comprehensive \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e12-month warranty\u003c\/strong\u003e\u003c\/span\u003e from date of delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eExpert Frequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What specific measures does the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO880\u003c\/strong\u003e\u003c\/span\u003e take to protect against inductive load spikes?\u003c\/strong\u003e\u003cbr\u003eAnswer: Each of the 16 output channels incorporates integrated inductive load suppression circuits and high-side driver clamps that safely absorb back-EMF energy generated when switching inductive loads like solenoid valves or relays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How should an engineer configure loop supervision for open-load detection on the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO880\u003c\/strong\u003e\u003c\/span\u003e?\u003c\/strong\u003e\u003cbr\u003eAnswer: You must set the resistance threshold parameter within the control builder configuration tool between 50 ohms and 2 kilohms, ensuring it matches the specific DC resistance of your connected field actuator coil to prevent nuisance trip alarms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Can the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO880\u003c\/strong\u003e\u003c\/span\u003e module be deployed in high-density vertical control cabinets without forced cooling?\u003c\/strong\u003e\u003cbr\u003eAnswer: Yes, but keep in mind that for vertical mounting configurations utilizing compact MTU bases, the maximum allowable ambient operating temperature decreases from 55 °C down to 40 °C to maintain thermal stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What safety integrity level is supported when running the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO880\u003c\/strong\u003e\u003c\/span\u003e in a single configuration versus redundant architecture?\u003c\/strong\u003e\u003cbr\u003eAnswer: The module is independently certified for SIL3 according to IEC 61508 in both single and redundant execution modes, provided that external wiring and safety loops adhere to your plant safety validation requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What buying guidance should procurement teams follow when sourcing replacement \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO880\u003c\/strong\u003e\u003c\/span\u003e units?\u003c\/strong\u003e\u003cbr\u003eAnswer: Always verify the exact article number \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3BSE028602R1\u003c\/strong\u003e\u003c\/span\u003e and check your existing MTU terminal block type (such as TU810V1 or TU830) to ensure complete physical keying and bus compatibility before purchasing.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45394542919862,"sku":"DO880","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DO880.jpg?v=1788148413","url":"https:\/\/www.plcsparehub.com\/products\/do880-3bse028602r1-abb-s800-digital-output-module-16-channel-sil3","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}