{"product_id":"do801-3bse020510r1-abb-s800l-24v-do-module-in-stock","title":"DO801 3BSE020510R1 ABB S800L 24V DO Module In Stock","description":"\u003ch3\u003eExecutive Summary\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO801 3BSE020510R1\u003c\/strong\u003e\u003c\/span\u003e is a high-density 16-channel digital output module optimized for 24 V d.c. field control within the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eABB S800L I\/O Series\u003c\/strong\u003e\u003c\/span\u003e family. Delivering current-sourcing drive capacity up to 0.5 A per channel, this compact hardware actuation unit directly commands solenoid valves, control relays, indicator panels, and alarm annunciators across automated process plants.\u003c\/p\u003e\n\u003cp\u003eEngineered for high-availability industrial networks, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO801\u003c\/strong\u003e\u003c\/span\u003e features short-circuit current limiting, thermal shutdown, and specialized Output Set predetermined State (OSP) logic to maintain system safety during fieldbus communication disruption.\u003c\/p\u003e\n\n\u003ch3\u003eCore Architecture \u0026amp; Driver Technology\u003c\/h3\u003e\n\u003cp\u003eEach actuation channel within the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO801 3BSE020510R1\u003c\/strong\u003e\u003c\/span\u003e integrates a high-side smart power driver protected by active current-limiting circuitry and optical isolation barriers. Galvanic opto-couplers separate internal +5 V ModuleBus backplane logic from external field power loops, suppressing destructive high-voltage spikes and ground potential shifts.\u003c\/p\u003e\n\u003cp\u003eThe output stage incorporates built-in inductive load suppression diodes that absorb flyback energy when switching inductive field devices like coils and relays. Built-in thermal sensors immediately disable output channels experiencing over-temperature conditions, resetting automatically once safe thermal margins are restored.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6; width: 30%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eABB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eS800L I\/O System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO801\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eArticle \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3BSE020510R1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eChannel Density \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e16 Channels, Current Sourcing Digital Output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eNominal Operating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e24 V d.c. (Continuous operating span: 10 to 30 V d.c., max 12–32 V d.c.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eContinuous Current Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e0.5 A continuous per channel (Short-circuit protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eIsolation Topology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e1 isolated group of 16 channels, groupwise isolated from ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eField Cable Reach\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eUp to 600 meters (656 yards) total wiring length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eWiring Termination\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eDetachable screw terminals (Solid: 0.05–2.5 mm² \/ 30–12 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003ePower Loss \u0026amp; Bus Draw\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eTyp. 2.1 W dissipation | 80 mA @ +5 V ModuleBus backplane supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eDielectric \u0026amp; Insulation Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e50 V rated insulation | 500 V a.c. dielectric test level\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eIP20 housing | ISA-S71.04 Class G3 conformal corrosive protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eHazardous Area Certifications\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eATEX Zone 2, Class I Div 2 cULus, Class I Zone 2 cULus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eMarine Class Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eCertified under ABS, BV, DNV, and LR marine standards\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eS800L Integrated Form Factor \u0026amp; Mechanical Layout\u003c\/h3\u003e\n\u003cp\u003eUnlike standard modular baseplate configurations, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO801 3BSE020510R1\u003c\/strong\u003e\u003c\/span\u003e utilizes the compact S800L profile with integrated detachable terminal blocks. This eliminates separate MTU purchases, reducing cabinet space requirements:\u003c\/p\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWiring Connection Parameters\u003c\/strong\u003e\n    \u003cul style=\"list-style-type: square; margin-top: 4px; padding-left: 25px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eSupported Conductor Sizes:\u003c\/strong\u003e Solid 0.05–2.5 mm² (30–12 AWG) \/ Stranded 0.05–1.5 mm² (30–12 AWG)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eTerminal Screw Torque:\u003c\/strong\u003e Recommended 0.5 to 0.6 Nm\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eWire Stripping Standard:\u003c\/strong\u003e 6.0 to 7.5 mm (0.24–0.30 inches)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eForm Factor Dimensions:\u003c\/strong\u003e 86.1 mm Width × 58.5 mm Depth × 110 mm Height (Weight: 0.24 kg)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTarget Equipment, Applications \u0026amp; Diagnostic Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO801\u003c\/strong\u003e\u003c\/span\u003e digital output unit is built for rugged discrete control loops across process industries, water treatment, and shipboard power systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Machinery \u0026amp; Application Scenarios:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePneumatic directional valve actuation on automated packaging and material handling conveyors.\u003c\/li\u003e\n  \u003cli\u003eLube oil skid solenoid control across turbomachinery packages.\u003c\/li\u003e\n  \u003cli\u003eInterlocking interposing relay drives in motor control center (MCC) power buckets.\u003c\/li\u003e\n  \u003cli\u003eMarine ballast pump control cabinets certified for off-shore vessel installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic \u0026amp; Fault Handling Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOSP (Output Set Predetermined State):\u003c\/strong\u003e Automatically forces output channels to user-defined safe states (e.g., Hold Last Value or Force Low) if communication with the controller drops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFront Diagnostic LEDs:\u003c\/strong\u003e Displays system status via main S LED alongside dedicated status LEDs for channels 1 through 16.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReal-time Fault Signaling:\u003c\/strong\u003e Reports Module Error, Module Warning, and Channel Error flags to central 800xA or Compact Control Builder diagnostic windows.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eConsider these critical engineering points when deploying the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO801 3BSE020510R1\u003c\/strong\u003e\u003c\/span\u003e module in field enclosures:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Vertical Cabinet Orientation Thermal Limits:\u003c\/strong\u003e Standard horizontal DIN-rail mounting permits full operation up to +55 °C (131 °F). However, when installed vertically, thermal convection efficiency decreases. In vertical orientation, derate the maximum ambient operating temperature to +40 °C (104 °F) to prevent nuisance thermal shutdowns on high-current channel channels.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e2. Inrush Current Management on Solenoid Loads:\u003c\/strong\u003e Although each output channel delivers 0.5 A continuously with internal current-limiting protection, high-power DC solenoids can create severe starting inrush spikes. If total load current on a channel exceeds the current limit threshold during turn-on, the channel driver may trigger short-circuit protection. Use interposing relays for heavy solenoids drawing over 0.5 A startup current.\u003c\/p\u003e\n\n\u003ch3\u003eLogistics, Packaging \u0026amp; Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuality Guarantee:\u003c\/strong\u003e Protected by comprehensive \u003cstrong\u003e12 Months Warranty\u003c\/strong\u003e coverage against component failures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFast Order Fulfillment:\u003c\/strong\u003e Orders process rapidly with dispatch guaranteed within 24 to 48 hours.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Express Courier Delivery:\u003c\/strong\u003e Expedited international air freight via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, or \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Integrity:\u003c\/strong\u003e Shipped in shock-absorbent anti-static packaging to ensure pristine physical condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Guide \u0026amp; Technical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSelection Guide: What is the main difference between S800 standard modules and S800L modules like the \u003cspan style=\"color: #0056b3;\"\u003eDO801\u003c\/span\u003e?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard S800 modules plug into separate Module Terminal Units (MTUs). S800L modules, such as the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO801 3BSE020510R1\u003c\/strong\u003e\u003c\/span\u003e, combine the I\/O electronics and detachable terminal blocks into a single unit, saving panel space and installation costs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow does OSP functionality safeguard process equipment during control network outages?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf fieldbus backplane communication fails, the OSP function automatically transitions outputs into preset fail-safe states, preventing uncommanded actuator movements that could damage machinery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs additional suppression required when switching external 24V inductive loads with the \u003cspan style=\"color: #0056b3;\"\u003eDO801\u003c\/span\u003e?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module includes built-in flyback diodes for standard inductive loads. For exceptionally large solenoids or long cable runs, adding an external flyback diode or RC snubber at the load terminals further reduces EMI radiation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat wire torque should field technicians apply to the detachable screw connectors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTighten the detachable terminal screws to a recommended torque of 0.5 to 0.6 Nm using stripped wire lengths between 6.0 and 7.5 mm.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan the \u003cspan style=\"color: #0056b3;\"\u003eDO801 3BSE020510R1\u003c\/span\u003e be deployed in harsh offshore environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module features ISA-S71.04 Class G3 conformal coating and holds major marine certifications (ABS, BV, DNV, LR), making it suitable for corrosive offshore and shipboard applications.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45394558255286,"sku":"DO801","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DO801.jpg?v=1788148431","url":"https:\/\/www.plcsparehub.com\/products\/do801-3bse020510r1-abb-s800l-24v-do-module-in-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}