{"product_id":"dl100-22aa2112-sick-dx100-time-of-flight-distance-sensor","title":"DL100-22AA2112 SICK Dx100 Time-of-Flight Distance Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #004080; font-weight: bold;\"\u003eDL100-22AA2112\u003c\/span\u003e \u003cspan style=\"color: #800000; font-weight: bold;\"\u003eDx100\u003c\/span\u003e time-of-flight distance sensor delivers high-precision linear positioning for demanding factory automation tasks. Utilizing advanced optical measurement principles, the \u003cspan style=\"color: #004080; font-weight: bold;\"\u003eDL100-22AA2112\u003c\/span\u003e achieves precise tracking across extended ranges on diamond-grade reflective tape. System architects integrate this \u003cspan style=\"color: #800000; font-weight: bold;\"\u003eDx100\u003c\/span\u003e series device into automated storage retrieval systems and heavy industrial cranes.\u003c\/p\u003e\n\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eCommissioning long-range optical distance sensors often introduces alignment challenges and ambient light interference on high-speed shop floors. In our field deployment reviews of the \u003cspan style=\"color: #004080; font-weight: bold;\"\u003eDL100-22AA2112\u003c\/span\u003e, maintenance teams resolved tracking jitter on stacking cranes by verifying that target reflectivity stayed uniform across the full 200-meter traverse. Leveraging the built-in PROFINET interface allows engineers to monitor real-time velocity curves and optical path degradation before minor alignment drifts cause unplanned downtime.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth\u003ePerformance Parameter\u003c\/th\u003e\n      \u003cth\u003eOperational Metric\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBrand \u0026amp; Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cspan style=\"color: #004080; font-weight: bold;\"\u003eDL100-22AA2112\u003c\/span\u003e (\u003cspan style=\"color: #800000; font-weight: bold;\"\u003eDx100\u003c\/span\u003e Series)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.15 m to 200 m (on diamond grade tape)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFreely adjustable (0.1 mm to 100 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRepeatability \u0026amp; Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRepeatability 1 mm | Accuracy ± 2.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResponse \u0026amp; Cycle Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eResponse 2 ms | Cycle time 1 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMovement Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax speed 15 m\/s | Max acceleration 15 m\/s²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInterface \u0026amp; Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROFINET, 2x Push-pull (PNP\/NPN), 1x MF1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e18V to 30V DC, \u0026lt; 250 mA current consumption\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65 rating, Aluminum die-cast housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDiagnostic Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #004080; font-weight: bold;\"\u003eDL100-22AA2112\u003c\/span\u003e features comprehensive onboard monitoring that communicates status flags directly through the \u003cspan style=\"color: #800000; font-weight: bold;\"\u003eDx100\u003c\/span\u003e communication architecture. Active diagnostics track sensor aging warning messages, optical path damping limits exceeded due to contamination, internal thermal boundary violations, measurement plausibility errors, laser readiness state, and heating circuit activation status.\u003c\/p\u003e\n\n\u003ch3\u003eTarget Applications \u0026amp; Equipment Suitability\u003c\/h3\u003e\n\u003cp\u003eThis optical distance measuring device excels in high-speed, dynamic industrial material handling environments. Primary deployment targets include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-bay automated storage and retrieval systems (AS\/RS)\u003c\/li\u003e\n  \u003cli\u003eHeavy industrial stacker cranes and transfer carriages\u003c\/li\u003e\n  \u003cli\u003eAutomotive body shop skillet conveyors and skid transfer lines\u003c\/li\u003e\n  \u003cli\u003ePort gantry cranes requiring long-range absolute positioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWarranty \u0026amp; Logistics Support\u003c\/h3\u003e\n\u003cp\u003eEvery \u003cspan style=\"color: #004080; font-weight: bold;\"\u003eDL100-22AA2112\u003c\/span\u003e unit ships with a comprehensive 12-month quality warranty covering structural and operational integrity. We ensure rapid global order fulfillment within 24 to 48 hours using trusted international carriers including FedEx, UPS, and DHL.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions \u0026amp; Buying Guide\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What primary factor determines the maximum 200-meter range for the DL100-22AA2112?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The sensor requires high-quality diamond-grade reflective tape installed along the measurement path to maintain optimal optical return signal strength.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How does the sensor handle severe optical path contamination in dusty industrial plants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The internal diagnostic suite triggers a warning signal when damping thresholds are exceeded, allowing maintenance crews to clean the PMMA window before a fault trip occurs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the adjustable resolution feature in the Dx100 series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It lets control engineers tune data throughput and precision granularity (from 0.1 mm up to 100 mm) to match specific PLC scan cycles and application demands.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the sensor operate outdoors without special environmental enclosures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The base unit carries an IP65 rating for indoor spaces; outdoor usage requires an optional cooling or heating case to maintain operational temperature limits between -20 °C and +75 °C.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How should I select between different distance sensor models for high-speed gantry cranes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Evaluate maximum velocity requirements, acceleration profiles, and required fieldbus compatibility (such as PROFINET); the \u003cspan style=\"color: #004080; font-weight: bold;\"\u003eDL100-22AA2112\u003c\/span\u003e fits high-speed applications running up to 15 m\/s.\u003c\/p\u003e","brand":"SICK","offers":[{"title":"Default Title","offer_id":47534013022390,"sku":"DL100-22AA2112","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DL100-22AA2112.jpg?v=1789885855","url":"https:\/\/www.plcsparehub.com\/products\/dl100-22aa2112-sick-dx100-time-of-flight-distance-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}