{"product_id":"di810-abb-s800-digital-input-module-16-channel-controller","title":"DI810 ABB S800 Digital Input Module | 16-Channel Controller","description":"\u003ch3\u003eProduct Overview \u0026amp; Engineering Insight\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DI810\u003c\/strong\u003e functions as a high-density \u003cstrong\u003eDigital Input Module\u003c\/strong\u003e engineered for the rugged \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e architecture. It processes sixteen 24 V d.c. sinking channels separated into two individually isolated groups, complete with dual process voltage supervision inputs.\u003c\/p\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: When engineering high-availability control systems with the \u003cstrong\u003eDI810\u003c\/strong\u003e module, configure your selectable digital filter times (2 ms to 16 ms) according to field noise characteristics. Setting proper filter parameters prevents transient line fluctuations from generating false state changes on industrial sensor loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specification Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem Parameter\u003c\/th\u003e\n\u003cth\u003eEngineering Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/s800-i-o\"\u003e\u003cstrong\u003eABB\u003c\/strong\u003e \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e\u003c\/a\u003e Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eDI810\u003c\/strong\u003e (Article Number: 3BSE008508R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Input Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e16 channels\u003c\/strong\u003e (Current sinking, 2 isolated groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Logic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\"0\" State: -30 to +5 V; \"1\" State: 15 to 30 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw \u0026amp; Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 mA at 24 V; Input impedance 3.5 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelectable Filtering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable filter times: 2, 4, 8, or 16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Field Reach\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSignal wiring distance up to \u003cstrong\u003e600 meters\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Compatibility \u0026amp; MTU Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Footprint:\u003c\/strong\u003e Standard compact S800 housing (45 mm width).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatching Base Units:\u003c\/strong\u003e Compatible with Termination Units including \u003cstrong\u003eTU810\u003c\/strong\u003e, \u003cstrong\u003eTU812\u003c\/strong\u003e, \u003cstrong\u003eTU814\u003c\/strong\u003e, \u003cstrong\u003eTU818\u003c\/strong\u003e, \u003cstrong\u003eTU830\u003c\/strong\u003e, \u003cstrong\u003eTU833\u003c\/strong\u003e, \u003cstrong\u003eTU838\u003c\/strong\u003e, and \u003cstrong\u003eTU850\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Keying:\u003c\/strong\u003e Factory-configured with \u003cstrong\u003eKeying code AA\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Protection:\u003c\/strong\u003e Built to \u003cstrong\u003eIP20\u003c\/strong\u003e standards with G3 corrosion protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuilt-In Diagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Supervision:\u003c\/strong\u003e Dedicated process voltage tracking for each of the two isolated channel groups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indication:\u003c\/strong\u003e Front panel LEDs display F (Fault), R (Run), W (Warning), and individual channel states (1-16).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Reporting:\u003c\/strong\u003e Group voltage failure signals transmit directly through the ModuleBus architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Suppression:\u003c\/strong\u003e Integrated optical isolation barriers and EMC protection components on every line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Compliance \u0026amp; Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +55°C (+32°F to +131°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Classifications:\u003c\/strong\u003e C1 Div 2 cULus, C1 Zone 2 cULus, and ATEX Zone 2 approved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Approvals:\u003c\/strong\u003e Certified by ABS, BV, DNV, and LR for marine usage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirectives:\u003c\/strong\u003e Compliant with CE, RoHS, and WEEE guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFulfillment, Logistics \u0026amp; Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e Factory-sealed \u003cstrong\u003eABB\u003c\/strong\u003e \u003cstrong\u003eDI810\u003c\/strong\u003e hardware unit with plug-in connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Providers:\u003c\/strong\u003e Secure worldwide dispatch via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing Schedule:\u003c\/strong\u003e Prompt fulfillment within \u003cstrong\u003e24-48 hours\u003c\/strong\u003e of purchase confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Assurance:\u003c\/strong\u003e Backed by a full \u003cstrong\u003e12-month warranty\u003c\/strong\u003e from Global PLC Spare HUB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Industrial Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDiscrete status monitoring for automated manufacturing conveyor lines.\u003c\/li\u003e\n\u003cli\u003eDigital interlock collection in oil and gas pumping stations.\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown system signal gathering in chemical plants.\u003c\/li\u003e\n\u003cli\u003ePower plant turbine auxiliary system contact monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: How does the groupwise isolation function on the \u003cstrong\u003eDI810\u003c\/strong\u003e module?\u003c\/h4\u003e\n\u003cp\u003eThe 16 channels split into two independent groups of eight. Each group features its own isolated voltage supervision line, preventing ground loops between separate power segments.\u003c\/p\u003e\n\u003ch4\u003eQ: What happens if the process supply voltage drops on one group of the \u003cstrong\u003eDI810\u003c\/strong\u003e?\u003c\/h4\u003e\n\u003cp\u003eThe module instantly detects the loss through its group supervision circuit and broadcasts a channel error code across the ModuleBus to alert the master controller.\u003c\/p\u003e\n\u003ch4\u003eQ: Can I use older base units when replacing a \u003cstrong\u003eDI810\u003c\/strong\u003e unit in an existing rack?\u003c\/h4\u003e\n\u003cp\u003eYes, as long as you match the designated AA keying code and utilize compatible MTUs such as the TU810V1 or TU830 already installed in your panel.\u003c\/p\u003e\n\u003ch4\u003eQ: What buying criteria should technicians follow when selecting replacement S800 modules?\u003c\/h4\u003e\n\u003cp\u003eAlways verify your exact catalog number, check the hardware revision suffix, and ensure the MTU backplane supports the specific channel voltage type.\u003c\/p\u003e\n\u003ch4\u003eQ: Why would an engineer adjust the digital filter times on the \u003cstrong\u003eDI810\u003c\/strong\u003e input channels?\u003c\/h4\u003e\n\u003cp\u003eExtending filter times from 2 ms to 16 ms helps suppress high-frequency electrical noise picked up over long field cabling runs before it registers as a false input toggle.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45382130303158,"sku":"DI810","price":132.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DI810.jpg?v=1787646459","url":"https:\/\/www.plcsparehub.com\/products\/di810-abb-s800-digital-input-module-16-channel-controller","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}