{"product_id":"cm577-eth-industrial-dual-port-plc-interface-abb-ac500","title":"CM577-ETH Industrial Dual-Port PLC Interface | ABB AC500","description":"\u003ch3\u003e\u003cstrong\u003eIndustrial Network Interface \u0026amp; Protocol Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eCM577-ETH\u003c\/strong\u003e\u003c\/span\u003e (Order Code: \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e1SAP170700R0001\u003c\/strong\u003e\u003c\/span\u003e) is a high-performance Ethernet communication coupler built for the ABB \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eAC500\u003c\/strong\u003e\u003c\/span\u003e programmable logic controller platform. Driven by an internal EC1 processor and 8 kByte dual-port RAM, this module equips PM57x, PM58x, and PM59x CPUs with deterministic Ethernet TCP\/IP, UDP\/IP, and dual-role Modbus TCP (Master\/Slave) connectivity. An integrated 2-port unmanaged switch enables daisy-chain line topologies directly at the control cabinet without external switching hardware.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eHardware, Memory \u0026amp; Environmental Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSubsystem Category\u003c\/th\u003e\n      \u003cth\u003eTechnical Parameter\u003c\/th\u003e\n      \u003cth\u003eEngineering Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eIdentification \u0026amp; Platform\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eManufacturer \u0026amp; Series\u003c\/td\u003e\n      \u003ctd\u003eABB — \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eAC500\u003c\/strong\u003e\u003c\/span\u003e PLC System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \u0026amp; Part Number\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eCM577-ETH\u003c\/strong\u003e\u003c\/span\u003e (\u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e1SAP170700R0001\u003c\/strong\u003e\u003c\/span\u003e)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCompatible CPUs \u0026amp; Bases\u003c\/td\u003e\n      \u003ctd\u003ePM57x, PM58x, PM59x CPUs; All TB5xx Terminal Bases\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"4\"\u003e\u003cstrong\u003eNetwork \u0026amp; Switch Specs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Interface\u003c\/td\u003e\n      \u003ctd\u003e2 × RJ45 Sockets (10\/100 Base-TX, Integrated 2-Port Switch)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransmission \u0026amp; Duplex\u003c\/td\u003e\n      \u003ctd\u003e10 or 100 Mbit\/s (Adjustable); Half\/Full-Duplex; Auto-Negotiation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSupported Protocols\u003c\/td\u003e\n      \u003ctd\u003eEthernet TCP\/IP, UDP\/IP, Modbus TCP (Master \u0026amp; Slave)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrame Types \u0026amp; Addressing\u003c\/td\u003e\n      \u003ctd\u003eEthernet II (RFC 894), IEEE 802.3 RX (RFC 1042); Rotary Switch (00..FF\u003csub\u003ehex\u003c\/sub\u003e)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eProcessing \u0026amp; Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOn-Board Processor\u003c\/td\u003e\n      \u003ctd\u003eEC1 Communication Processor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInternal \u0026amp; Dual-Port RAM\u003c\/td\u003e\n      \u003ctd\u003e256 kByte Internal RAM (EC1); 8 kByte Dual-Port Memory\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExternal Memory\u003c\/td\u003e\n      \u003ctd\u003e2 × 128 kByte RAM (Webserver); 512 kByte Firmware Flash + 2 MByte Web Flash\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"2\"\u003e\u003cstrong\u003ePower \u0026amp; Diagnostics\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower Supply \u0026amp; Draw\u003c\/td\u003e\n      \u003ctd\u003eVia Terminal Base Bus; Typ. 65 mA at 24 V DC terminal base (420 mA bus load)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLED State Indicators\u003c\/td\u003e\n      \u003ctd\u003e5 Status LEDs (PWR, RDY, RUN, STA, ERR) + 2 × LINK, 2 × ACT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"4\"\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n      \u003ctd\u003e28 mm (W) × 135 mm (H) × 62 mm (D); Approx. 120 g – 150 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0°C to +60°C (Horizontal Mounting); XC variant (1SAP370700R0001) -40°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration \u0026amp; Shock\u003c\/td\u003e\n      \u003ctd\u003eEN 61131-2: 2–15 Hz (3.5 mm), 15–150 Hz (1 g); Shock: 15 g, 11 ms half-sine\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting \u0026amp; Protection\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN Rail (EN 50022) or 4 mm Screws (1.2 Nm torque); IP20, UL 94 Housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCabinet Installation \u0026amp; Commissioning Protocol\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eMount the compatible \u003cstrong\u003eTB5xx\u003c\/strong\u003e terminal base horizontally onto a 35 mm DIN rail (7.5 mm or 15 mm depth) or fasten directly to the backplate using M4 screws tightened to 1.2 Nm.\u003c\/li\u003e\n  \u003cli\u003eDial the hexadecimal rotary switches (00 to FF\u003csub\u003ehex\u003c\/sub\u003e) on the module face to assign a unique hardware station identifier prior to seating the unit.\u003c\/li\u003e\n  \u003cli\u003eSnap the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eCM577-ETH\u003c\/strong\u003e\u003c\/span\u003e firmly onto the terminal base communication coupler slot until the locking mechanism engages.\u003c\/li\u003e\n  \u003cli\u003eConnect shielded CAT5e\/CAT6 patch cables to the dual RJ45 ports and confirm green LINK\/ACT LED illumination alongside solid PWR and RDY status indicators.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Selection \u0026amp; Environment Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify control cabinet thermal profiles: select the standard \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e1SAP170700R0001\u003c\/strong\u003e\u003c\/span\u003e for standard indoor cabinets (0°C to +60°C) or specify the conformal-coated XC version (\u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e1SAP370700R0001\u003c\/strong\u003e\u003c\/span\u003e) for harsh corrosive gases, salt mist, or sub-zero installations down to -40°C.\u003c\/li\u003e\n  \u003cli\u003eConfirm horizontal rack orientation is maintained across the AC500 backplane to satisfy convection cooling and EN 61131-2 vibration ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eControl Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the integrated 2-port switch on the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003eCM577-ETH\u003c\/strong\u003e\u003c\/span\u003e simplify multi-drop PLC cabinet wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The built-in 10\/100 Base-TX switch internally bridges both RJ45 sockets, allowing engineers to daisy-chain neighboring AC500 racks, HMIs, or remote I\/O islands in a linear topology without consuming extra ports on an external industrial Ethernet switch.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What role does the 8 kByte dual-port memory play during high-speed Modbus TCP polling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Dual-port RAM acts as an asynchronous hardware buffer between the EC1 communication processor and the main AC500 CPU, enabling deterministic data exchange without stalling main PLC scan cycles during heavy TCP\/IP traffic bursts.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can technicians lock port speed and duplex settings instead of relying on auto-negotiation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. While auto-negotiation is active by default, engineers can manually force 10 Mbit\/s or 100 Mbit\/s and half\/full-duplex modes within the Automation Builder hardware configuration to prevent duplex mismatches with legacy managed switches.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What diagnostic checks resolve a flashing ERR LED during initial network commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Inspect the rotary station switches (00..FF\u003csub\u003ehex\u003c\/sub\u003e) to verify they match the slot address configured in the project tree, check for duplicate IP assignments on the subnet, and confirm the module is seated squarely on a TB5xx terminal base.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: When is it necessary to upgrade from the standard \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e1SAP170700R0001\u003c\/strong\u003e\u003c\/span\u003e to the XC variant?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Transition to the XC version whenever ambient temperatures fall below 0°C or exceed +60°C, or when deploying panels in marine, wastewater, or petrochemical environments containing H\u003csub\u003e2\u003c\/sub\u003eS and corrosive airborne contaminants.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68078284406966,"sku":"CM577-ETH","price":224.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/CM577-ETH-1.jpg?v=1794810796","url":"https:\/\/www.plcsparehub.com\/products\/cm577-eth-industrial-dual-port-plc-interface-abb-ac500","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}