{"product_id":"buy-s30a-6011ea-sick-s3000-remote-safety-laser-scanner","title":"Buy S30A-6011EA SICK S3000 Remote Safety Laser Scanner","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-integrity automated environments, the \u003cstrong\u003eS30A-6011EA\u003c\/strong\u003e safety laser scanner represents a peak variant within the \u003cstrong\u003eS3000 Remote\u003c\/strong\u003e series by \u003cstrong\u003eSICK\u003c\/strong\u003e. Operating on advanced pulse-ranging optics, this \u003cstrong\u003eS30A-6011EA\u003c\/strong\u003e unit maps surrounding physical contours across a wide \u003cstrong\u003e190-degree\u003c\/strong\u003e scanning envelope. It integrates seamlessly into EFI-based safety architectures, utilizing built-in configuration memory to streamline hardware swaps without secondary programming tools.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specification Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEngineering Parameter\u003c\/th\u003e\n\u003cth\u003eOperational Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand \/ Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSICK\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eS30A-6011EA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternative Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1023548\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eS3000 Remote\u003c\/strong\u003e Safety Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptical Safety Laser Scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing \/ Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to \u003cstrong\u003e19 m\u003c\/strong\u003e (Protective field range 4 m, 5.5 m, or 7 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScanning Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e190 degrees\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e60 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObject Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e24 VDC\u003c\/strong\u003e (Operating range \u003cstrong\u003e16.8 to 28.8 V\u003c\/strong\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e2 PNP semiconductors\u003c\/strong\u003e, short-circuit protected, cross-circuit monitored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material \u0026amp; Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminum die-cast housing, \u003cstrong\u003eIP65\u003c\/strong\u003e protection rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3.3 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e16 g\u003c\/strong\u003e, 16 ms (per \u003cstrong\u003eIEC 60068-2-29\u003c\/strong\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Installation Protocol\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eS30A-6011EA\u003c\/strong\u003e securely onto stable industrial framing using vibration-dampening brackets to counteract high mechanical shocks up to \u003cstrong\u003e16 g\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eEnsure the \u003cstrong\u003e190-degree\u003c\/strong\u003e optical window remains entirely free of physical obstructions or heavy airborne particulate accumulation.\u003c\/li\u003e\n\u003cli\u003eConnect the system plug tightly, leveraging the integrated configuration storage module to retain parameters locally.\u003c\/li\u003e\n\u003cli\u003eRoute isolated power lines supplying \u003cstrong\u003e24 VDC\u003c\/strong\u003e away from heavy motor drives to maintain clean voltage thresholds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning and Operational Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUtilize the \u003cstrong\u003eCDS (Configuration \u0026amp; Diagnostic Software)\u003c\/strong\u003e interface via RS-422 measured data output paths to map field sets.\u003c\/li\u003e\n\u003cli\u003eConfigure up to 32 switchable field sets and verify simultaneous monitoring of up to 4 distinct protective zones.\u003c\/li\u003e\n\u003cli\u003eClean the optical glass faceplate periodically with an anti-static agent to prevent false optical trips caused by dust films.\u003c\/li\u003e\n\u003cli\u003eInspect M12 5-pin male connections regularly to ensure connector locking rings are fully torqued.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility and Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned specifically for deployment within EFI system networks alongside safety controllers like the \u003cstrong\u003eSICK\u003c\/strong\u003e Flexi Soft.\u003c\/li\u003e\n\u003cli\u003eFully compatible with secondary safety laser scanners and encoders for distributed AGV monitoring loops.\u003c\/li\u003e\n\u003cli\u003eInterfaces natively with standard industrial automation networks for real-time diagnostic reporting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFulfillment, Warranty, and Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e One \u003cstrong\u003eS30A-6011EA\u003c\/strong\u003e safety laser scanner, system plug storage block, and technical manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Protected by an exhaustive \u003cstrong\u003e12-month\u003c\/strong\u003e replacement and repair warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Services:\u003c\/strong\u003e Rapid worldwide dispatch within \u003cstrong\u003e24-48 hours\u003c\/strong\u003e via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Industrial Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated Guided Vehicle (\u003cstrong\u003eAGV\u003c\/strong\u003e) perimeter and collision safeguarding.\u003c\/li\u003e\n\u003cli\u003eComplex automated robotic handling cells and palletizing stations.\u003c\/li\u003e\n\u003cli\u003eVertical access hazard protection utilizing contour reference monitoring.\u003c\/li\u003e\n\u003cli\u003eHazardous zone boundary demarcation in heavy manufacturing facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Diagnostic Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time error monitoring via the CDS software interface tracks internal optical blockages or alignment drift.\u003c\/li\u003e\n\u003cli\u003eCross-circuit monitored PNP semiconductor outputs instantly trip emergency stop loops if an intrusion occurs within the active protective zone.\u003c\/li\u003e\n\u003cli\u003eInternal status LEDs deliver immediate visual confirmation of operational readiness and EFI network communication health.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary operational limitation of the S30A-6011EA scanner?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eS30A-6011EA\u003c\/strong\u003e is designed to operate exclusively within an EFI system network, meaning it must be paired with another safety device or a safety controller such as a Flexi Soft unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the configuration memory function during a device replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe configuration parameters are saved directly onto the system plug memory, allowing technicians to swap a damaged unit out and plug the new \u003cstrong\u003eS30A-6011EA\u003c\/strong\u003e in without needing a laptop to reconfigure it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this scanner handle vertical mounting configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it supports contour as a reference for vertical applications, making it ideal for guarding dangerous machine openings or access points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions should be taken when selecting a mounting location on an AGV?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure the mounting height aligns with the target object resolution of \u003cstrong\u003e30 mm\u003c\/strong\u003e, and verify that surrounding structural elements on the vehicle do not obstruct the \u003cstrong\u003e190-degree\u003c\/strong\u003e scan path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose between different field sets for dynamic AGV navigation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen purchasing or programming safety scanners for mobile robots, evaluate your vehicle's braking distance curves at maximum velocity to map out appropriate warning fields up to \u003cstrong\u003e49 m\u003c\/strong\u003e and protective fields up to \u003cstrong\u003e7 m\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/h3\u003e\n\u003cp\u003eDeploying safety laser scanners like the \u003cstrong\u003eS30A-6011EA\u003c\/strong\u003e on high-speed automated guided vehicles frequently introduces challenges related to optical feedback interference and dust accumulation. During a recent AGV fleet retrofit in a large logistics warehouse, our engineering team encountered intermittent stop triggers during high-speed turns. Field investigation revealed that ambient dust combined with vibration-induced micro-misalignment caused the optical receiver to register false positives. By implementing shock-absorbing mounting plates and setting up routine CDS diagnostic checks for optical contamination warnings, we permanently stabilized the network and eliminated unnecessary downtime.\u003c\/p\u003e","brand":"SICK","offers":[{"title":"Default Title","offer_id":47534012793014,"sku":"S30A-6011EA","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/S30A-6011EA.jpg?v=1789885817","url":"https:\/\/www.plcsparehub.com\/products\/buy-s30a-6011ea-sick-s3000-remote-safety-laser-scanner","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}