{"product_id":"buy-do814-abb-s800-16-channel-digital-output-module","title":"Buy DO814 ABB S800 16-Channel Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO814\u003c\/strong\u003e\u003c\/span\u003e is a high-performance 16-channel digital output module engineered by \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eABB\u003c\/strong\u003e\u003c\/span\u003e within the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eS800 I\/O\u003c\/strong\u003e\u003c\/span\u003e series. This module delivers 24 VDC current-sinking outputs across two isolated groups, complete with individual process voltage supervision inputs. Global PLC Spare HUB's Insight highlights that utilizing built-in OSP (Output Set Point) logic ensures critical final control elements transition to safe, predetermined states instantly upon communication loss or controller fault detection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \/ Manufacturer:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eABB\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries \/ Architecture:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/s800-i-o\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eS800 I\/O\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e \/ Modular DIN-rail mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number \/ Article:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO814\u003c\/strong\u003e\u003c\/span\u003e (3BUR001455R1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e 16-Channel Digital Output (Current Sinking)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Range \u0026amp; Rating:\u003c\/strong\u003e 24 VDC (12-32 VDC operating), 0.5 A max continuous current per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e Groupwise isolated from ground (50 V rated insulation, 500 VAC dielectric test)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation \u0026amp; Draw:\u003c\/strong\u003e Typical 2.1 W; 80 mA current consumption from +5 V ModuleBus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e 45 mm (W) x 119 mm (H) x 102 mm (D) [111 mm with connector]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.18 kg (0.4 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px; margin-bottom: 15px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eProtection \u0026amp; Environmental Parameter\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eEngineering Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eProof current-limited output to ground and 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eThermal \u0026amp; Overvoltage Protection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIntegrated over-temperature shutdown and inductive load suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0 °C to +55 °C (+32 °F to +131 °F); ISA-S71.04 G3 corrosion rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eCompatible MTUs\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eTU810V1, TU810, TU812, TU814, TU830, TU833, TU838 (Keying Code: BE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTU Alignment:\u003c\/strong\u003e Mount the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO814\u003c\/strong\u003e\u003c\/span\u003e module onto a compatible \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eS800 I\/O\u003c\/strong\u003e\u003c\/span\u003e Module Termination Unit (such as TU810V1) with matching BE keying pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Routing:\u003c\/strong\u003e Terminate field load cables up to 600 meters (656 yards) while keeping inductive load suppression diodes active across DC solenoids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Clearance:\u003c\/strong\u003e Ensure proper vertical spacing, noting that maximum ambient temperature drops to 40 °C (104 °F) when installed vertically in compact MTU arrangements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDebugging and Maintenance Convenience\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront LED Diagnostics:\u003c\/strong\u003e Monitor F (Fault), R (Run), W (Warning), O (OSP), and individual Channel 1-16 status LEDs for instant loop verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Voltage Supervision:\u003c\/strong\u003e Review group-level voltage error signals via the ModuleBus if external field supply drops below operating thresholds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Capability:\u003c\/strong\u003e Replace faulty modules safely without tools thanks to modular S800 architecture and mechanical keying protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Fully compatible with \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eABB\u003c\/strong\u003e\u003c\/span\u003e control platforms utilizing the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eS800 I\/O\u003c\/strong\u003e\u003c\/span\u003e bus architecture and standard MTU blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Capability:\u003c\/strong\u003e Generates automated channel and module error warnings for short-circuit conditions, over-temperature trips, and lost process supply voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal PLC Spare HUB Review:\u003c\/strong\u003e Commissioning engineers note that the dual group-wise isolation barrier successfully blocks transient ground surges across sprawling remote instrumentation skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Control Systems (DCS):\u003c\/strong\u003e Interfacing high-density 24 VDC solenoid valves and relay actuators in petrochemical processing plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Automation Cells:\u003c\/strong\u003e Controlling high-speed inductive DC loads on automated packaging and assembly machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Propulsion Control:\u003c\/strong\u003e Managing auxiliary digital outputs on shipboard automation panels meeting ABS, BV, DNV, and LR standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications, Logistics, and Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e Complies with EN 61010-1, UL 61010-1, ATEX Zone 2, C1 Div 2 cULus, and marine safety standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogistics \u0026amp; Dispatch:\u003c\/strong\u003e Fast 24-48 hour dispatch window utilizing reliable international carriers including \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Protected by a full \u003cstrong\u003e12-month warranty\u003c\/strong\u003e from the original date of supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePacking List:\u003c\/strong\u003e One \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO814\u003c\/strong\u003e\u003c\/span\u003e digital output module and technical compliance sheet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What triggers an OSP (Output Set Point) state on the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDO814\u003c\/strong\u003e\u003c\/span\u003e module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: OSP activates automatically when the module detects a communication timeout with the controller, forcing outputs to a pre-configured safe state.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 16 output channels sink current from independent external power sources?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the 16 channels are divided into two isolated groups of eight, where each group shares a common process voltage supervision input and supply rail.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why are individual channel status LEDs flashing during normal operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Flashing or unlit LEDs typically indicate an open load wire, a short-circuit condition to ground, or an over-temperature thermal trip on that specific channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What MTU backplane connector keying code is required for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module requires an MTU with Keying Code BE to ensure physical prevention of insertion into incorrect voltage terminal slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Purchasing Guidance: How do I select the right MTU base for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Choose standard terminal units like the TU810V1 or TU812 depending on whether you require screw or spring-clamp field wiring connections.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45446621692086,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/DO814-3.jpg?v=1789379576","url":"https:\/\/www.plcsparehub.com\/products\/buy-do814-abb-s800-16-channel-digital-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}