{"product_id":"bmep583040-modicon-m580-ethernet-pac-controller-schneider-electric","title":"BMEP583040 Modicon M580 Ethernet PAC Controller Schneider Electric","description":"\u003ch3\u003e\u003cstrong\u003eePAC Architecture \u0026amp; Control Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAutomation architects deploy the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBMEP583040\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSchneider Electric\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eModicon M580\u003c\/strong\u003e\u003c\/span\u003e Level 3 ePAC CPU as the central Ethernet-native processor for medium-to-large process and hybrid control systems. Powered by a 600 MHz ARM dual-core engine with 12 MB of integrated program memory, this controller executes 40 Kinst\/ms boolean logic while natively managing deterministic Remote I\/O (RIO) and Distributed I\/O (DIO) networks. Designed for seamless migration from legacy Quantum and Premium platforms, it mounts into X80 Ethernet backplanes to unify plant-floor control with enterprise cybersecurity.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcessing Engine \u0026amp; Memory Allocation:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCore Processor:\u003c\/strong\u003e 600 MHz ARM dual-core microprocessor architecture (Level 3 performance tier)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eExecution Benchmark:\u003c\/strong\u003e 40 Kinst\/ms (100% boolean instructions) \/ 30 Kinst\/ms (mixed instruction set)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eOnboard Memory:\u003c\/strong\u003e 12 MB integrated RAM for application logic; 768 KB dedicated data memory\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eRemovable Storage:\u003c\/strong\u003e Optional 4 GB industrial SD card (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBMXRMS004GPF\u003c\/strong\u003e\u003c\/span\u003e) for firmware and application backup\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Scalability \u0026amp; I\/O Topology:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMaximum I\/O Capacity:\u003c\/strong\u003e Up to 3,072 discrete I\/O points and 768 analog I\/O channels\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eLocal Rack Architecture:\u003c\/strong\u003e Supports 1 main rack plus up to 7 expansion racks (8 local racks total)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eField Network Reach:\u003c\/strong\u003e Manages up to 16 deterministic Remote I\/O (RIO) drops and 61 Distributed I\/O (DIO) devices\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eApplication Channels:\u003c\/strong\u003e 64 dedicated intelligent application channels (motion, counting, serial)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEmbedded Ethernet \u0026amp; Diagnostic Interfaces:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFront-Panel Ports:\u003c\/strong\u003e 1× RJ45 Ethernet service port, 2× RJ45 10\/100 Mbps RIO\/DIO Ethernet ports, 1× USB Mini-B (480 Mbps)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eIndustrial Protocols:\u003c\/strong\u003e Native EtherNet\/IP, Modbus TCP\/IP, HTTP\/HTTPS embedded web server, and Modbus Serial\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eBackplane Expansion:\u003c\/strong\u003e Compatible with X80 Ethernet racks (4, 6, 8, 12-slot single PSU; 6, 10-slot redundant PSU) and \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBMENOC03xx\u003c\/strong\u003e\u003c\/span\u003e \/ \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBMENUA0100\u003c\/strong\u003e\u003c\/span\u003e modules\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" width=\"100%\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth align=\"left\"\u003eSystem Domain\u003c\/th\u003e\n      \u003cth align=\"left\"\u003eEngineering Parameter\u003c\/th\u003e\n      \u003cth align=\"left\"\u003eRated Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIdentification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eManufacturer, Model \u0026amp; Series\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSchneider Electric BMEP583040\u003c\/strong\u003e\u003c\/span\u003e (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eModicon M580\u003c\/strong\u003e\u003c\/span\u003e ePAC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eComputation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCPU Speed \u0026amp; Program Memory\u003c\/td\u003e\n      \u003ctd\u003e600 MHz ARM dual-core; 12 MB program RAM \/ 768 KB data RAM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDiscrete, Analog \u0026amp; Network Drops\u003c\/td\u003e\n      \u003ctd\u003e3,072 discrete \/ 768 analog; 16 RIO drops; 61 DIO devices\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBackplane Power \u0026amp; Draw\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (19.2–31.2 V DC); 7.2 W power consumption (300 mA @ 24 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOperating Temp, Humidity \u0026amp; Ingress\u003c\/td\u003e\n      \u003ctd\u003e0 °C to +60 °C; 5%–95% non-condensing RH; IP20 protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDimensions, Mass \u0026amp; Slot Footprint\u003c\/td\u003e\n      \u003ctd\u003e100 × 56 × 93 mm; 0.849 kg; occupies slots 0 and 1 (2 slots)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEngineering Tools\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSoftware \u0026amp; Lifecycle Status\u003c\/td\u003e\n      \u003ctd\u003eEcoStruxure Control Expert \/ Machine Expert (Unity Pro XL); Active\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eField Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I configure a redundant RSTP ring topology using the dual RIO\/DIO Ethernet ports on the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBMEP583040\u003c\/strong\u003e\u003c\/span\u003e?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Connect Port 2 (Device Network) and Port 3 (Device Network) directly to your first and last CRA (Remote I\/O Adapter) drops in a closed loop, then enable Rapid Spanning Tree Protocol (RSTP) in the CPU Ethernet properties to achieve sub-50 ms network recovery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can I mix legacy Modicon X80 backplanes with the new Ethernet backplanes for this processor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBMEP583040\u003c\/strong\u003e\u003c\/span\u003e supports both BMEXBPxx00 Ethernet backplanes and legacy BMXXBPxx00 X-bus backplanes, though Ethernet communication modules like BMENOC0301 require dedicated Ethernet backplane slots to achieve full gigabit backplane throughput.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What is the practical function of the top Ethernet service port versus the lower two RIO\/DIO ports?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The upper RJ45 service port mirrors network traffic for Wireshark packet diagnostics, connects local HMI panels, or hosts engineering workstation programming sessions without consuming deterministic bandwidth reserved for the lower RIO\/DIO control ring.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Why must this CPU always be installed in slots 0 and 1 of the main rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: The \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBMEP583040\u003c\/strong\u003e\u003c\/span\u003e is a double-width processor module keyed exclusively for the dedicated CPU bus interface located directly adjacent to the rack power supply in slots 0 and 1.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: How does the optional BMXRMS004GPF SD card simplify emergency hardware replacement on the plant floor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Storing the compiled project and IP configuration on the industrial SD card allows maintenance technicians to transfer the card into a spare CPU and restore full plant operation automatically upon power-up without needing a programming laptop.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68083615596726,"sku":"BMEP583040","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BMEP583040-3.jpg?v=1794899393","url":"https:\/\/www.plcsparehub.com\/products\/bmep583040-modicon-m580-ethernet-pac-controller-schneider-electric","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}