{"product_id":"bmenos0300c-modicon-x80-switch-module-schneider-electric-network","title":"BMENOS0300C Modicon X80 Switch Module Schneider Electric Network","description":"\u003ch3\u003e\n\u003cstrong\u003eBMENOS0300C\u003c\/strong\u003e Architectural Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eBMENOS0300C\u003c\/span\u003e\u003c\/strong\u003e is a ruggedized, three-port managed network switch module engineered explicitly for the \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eModicon X80\u003c\/span\u003e\u003c\/strong\u003e automation platform. This intelligent hardware delivers dedicated routing for EtherNet\/IP device networks and specialized local service ports. Built for harsh processing environments, the assembly features comprehensive factory conformal coating as standard reinforcement. The infrastructure mounts natively into intelligent industrial backplanes to facilitate high-speed data multiplexing and deterministic control communication. Control engineers deploy this component to optimize sub-network topologies, isolate control traffic, and maintain uninterrupted uptime across demanding automation backbones.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eBMENOS0300C\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eModicon X80\u003c\/span\u003e\u003c\/strong\u003e Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Managed Ethernet Switch Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Ports:\u003c\/strong\u003e 3 Communications Interface Channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Routing Assignment:\u003c\/strong\u003e Dedicated EtherNet\/IP Device Network and Local Service Port Access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e Native EtherNet\/IP Industrial Layer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Supply Input Voltage:\u003c\/strong\u003e 24 V DC Sourced via the Backplane Bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Power Consumption at 25 °C:\u003c\/strong\u003e 3.3 W Maximum Drawing 135 mA Current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Power Consumption at 60 °C:\u003c\/strong\u003e 4.5 W Maximum Drawing 185 mA Current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Module Format:\u003c\/strong\u003e Standard Expansion Slot Occupancy Profile\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection Rating:\u003c\/strong\u003e IP20 Sealed Housing Design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection Standard:\u003c\/strong\u003e Category II Certified Circuit Protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Component Weight:\u003c\/strong\u003e 264.0 Grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Resiliency \u0026amp; Harsh Atmosphere Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical Gas Immunity Level:\u003c\/strong\u003e Gas Resistant Class Gx Conformant to ISA S71.04 Standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Gas Immunity Standard:\u003c\/strong\u003e Gas Resistant Class 3C4 Conformant to IEC 60721-3-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParticulate Matter Immunity:\u003c\/strong\u003e Dust Resistant Class 3S4 and Sand Resistant Class 3S4 to IEC 60721-3-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAtmospheric Moisture Protection:\u003c\/strong\u003e Mold Growth and Fungal Spore Resistant Class 3B2 (IEC 60721-3-3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Air Resiliency:\u003c\/strong\u003e Salt Resistant Level 2 Conformant to IEC 68252 Compliance Matrix\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Boundary Classification:\u003c\/strong\u003e Hazardous Location Class I Division 2 Rated Architecture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosive Area Safety Registry:\u003c\/strong\u003e ATEX Zone 2\/22 and IECEx Zone 2\/22 Explosion Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSubstation \u0026amp; Heavy Industrial Standards Profile\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Utility Substation Certification:\u003c\/strong\u003e EN\/IEC 61850-3 Location G Compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Interface Specifications:\u003c\/strong\u003e EN\/IEC 61000-6-5 Interface Type 1 and Type 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Controllers General Criteria:\u003c\/strong\u003e EN\/IEC 61131-2 Structural Standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Laboratory Safety Requirements:\u003c\/strong\u003e EN\/IEC 61010-2-201, UL 61010-2-201, and CSA C22.2 No 61010-2-201\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Environmental Type Approval:\u003c\/strong\u003e International Association of Classification Societies IACS E10\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eClimatic \u0026amp; Operational Thresholds\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Ambient Temperature:\u003c\/strong\u003e 0 to 60 Degrees Celsius with No Thermal Derating Required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Ambient Temperature:\u003c\/strong\u003e -40 to 85 Degrees Celsius Extended Thermal Envelope\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Ambient Humidity:\u003c\/strong\u003e 95% Continuous Non-condensing Maximum Limit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Atmospheric Altitude:\u003c\/strong\u003e Less than or Equal to 2000 Meters Above Sea Level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogistical Transport Altitude:\u003c\/strong\u003e Maximum Peak Limit up to 3000 Meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Integration \u0026amp; Equipment Suitability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent Backplane Architectures:\u003c\/strong\u003e Modicon BMEXBP Ethernet+X-Bus Mixed Backplanes (BMEXBP0400, BMEXBP0800)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Processor Nodes:\u003c\/strong\u003e Modicon M580 ePAC CPU Controllers (BMEP582040, BMEP584040)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed I\/O System Architectures:\u003c\/strong\u003e Modicon Quantum \/ Premium Transition Drops via X80 Remote Architecture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSevere Corrosive Environments:\u003c\/strong\u003e Petrochemical Processing Facilities and Wastewater Treatment Operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSegregation of real-time machine interlocking data traffic from upper-level SCADA polling lines.\u003c\/li\u003e\n\u003cli\u003eProviding isolated local engineering access terminals directly on the equipment enclosure door via the service port.\u003c\/li\u003e\n\u003cli\u003eEthernet communication distribution within localized sub-rings utilizing specialized industrial redundancy rings.\u003c\/li\u003e\n\u003cli\u003eRemote telemetry network interface deployment in corrosive, humid coastal environments or salt-heavy installations.\u003c\/li\u003e\n\u003cli\u003eHigh-density data routing inside electrical power distribution sub-stations requiring strict surge protection compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRUN LED (Green):\u003c\/strong\u003e Steady illumination confirms the network module firmware is fully initialized and operational.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eERR LED (Red):\u003c\/strong\u003e Signals an internal microprocessor failure, hardware lock, or active device error condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMod Status LED (Green\/Red):\u003c\/strong\u003e Double-color light providing visual confirmation of the overall module logic configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Status LED (Green\/Red):\u003c\/strong\u003e Double-color light displaying real-time connection handshake health across the network fabric.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance \u0026amp; Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Mark Safety Directives\u003c\/li\u003e\n\u003cli\u003eLow Voltage Framework Directive 2014\/35\/EU\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003eATEX Explosive Atmospheres Safety Directive 2014\/34\/EU\u003c\/li\u003e\n\u003cli\u003eUnderwriters Laboratories Industrial Control Safety UL Listed\u003c\/li\u003e\n\u003cli\u003eCanadian Standards Association Industrial Systems CSA Certified\u003c\/li\u003e\n\u003cli\u003eRegulatory Compliance Mark RCM \/ Eurasian Conformity Certification EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging Dimensions \u0026amp; Logistical Units\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type 1 Unit:\u003c\/strong\u003e Individual PCE Container Layout\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type 1 Envelope Dimensions:\u003c\/strong\u003e 5.800 cm (Height) x 11.200 cm (Width) x 12.200 cm (Length)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type 1 Dead Weight:\u003c\/strong\u003e 264.000 Grams Total\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type 2 Bulk Unit:\u003c\/strong\u003e S02 Multi-Pack Shipping Carton containing 5 individual modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type 2 Envelope Dimensions:\u003c\/strong\u003e 15.000 cm (Height) x 30.000 cm (Width) x 40.000 cm (Length)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type 2 Bulk Weight:\u003c\/strong\u003e 1.636 Kilograms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e One Network Switch Unit, Factory Inspection Record, Technical Reference Manual\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Protection Term:\u003c\/strong\u003e 12-Month Factory Defects Warranty Coverage Agreement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuthorized Freight Networks:\u003c\/strong\u003e Expedited international shipping via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing Speed:\u003c\/strong\u003e Secured global transit dispatch routines complete within 24 to 48 hours of order processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eBMENOS0300C\u003c\/span\u003e\u003c\/strong\u003e stands out because it brings advanced electrical substation and chemical resistance metrics right down to the standard I\/O rack level. While typical Ethernet modules fail rapidly under exposure to hydrogen sulfide or high humidity, this module handles aggressive environments seamlessly due to its severe duty conformal coating. The dual certification under Class I Div 2 and ATEX Zone 2 allows engineers to safely extend high-speed Ethernet fabrics into hazardous areas. It reduces the footprint required for extra networking hardware by combining control routing and local field maintenance ports onto a single, backplane-powered slot.\u003c\/p\u003e\n\u003ch3\u003eProcurement Selection Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpecify the \"C\" denoted conformal-coated variant if your plant atmosphere has corrosive elements or high humidity.\u003c\/li\u003e\n\u003cli\u003eConfirm your target backplane is an Ethernet-compatible BMEXBP rack variant to match the high-speed data traces.\u003c\/li\u003e\n\u003cli\u003eEnsure your current power supply calculation includes the higher 185 mA current consumption profile if operating near the 60 °C upper thermal boundary.\u003c\/li\u003e\n\u003cli\u003eAvoid using this infrastructure module for wide-area fiber optic distribution without external media converters since all native connections are copper ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch3\u003eWhat design purpose does the \"C\" suffix indicate for this communication interface card?\u003c\/h3\u003e\n\u003cp\u003eThe \"C\" suffix means the printed circuit board has a factory conformal coating. This protective layer shields the internal circuits from dust, salt air, chemical gases, and fungal growth in harsh environments.\u003c\/p\u003e\n\u003ch3\u003eCan this card be plugged into an older standard TSXBPX series X-Bus backplane?\u003c\/h3\u003e\n\u003cp\u003eNo. The network module requires an Ethernet-enabled BMEXBP series backplane. It uses the specific high-speed Ethernet pins that are not present on older legacy X-Bus racks.\u003c\/p\u003e\n\u003ch3\u003eHow does the module manage the difference between critical machine control data and local engineering traffic?\u003c\/h3\u003e\n\u003cp\u003eThe card uses integrated firmware mapping. This setup isolates the service port traffic from the deterministic EtherNet\/IP loop data, preventing localized diagnostic tasks from delaying real-time control routines.\u003c\/p\u003e\n\u003ch3\u003eWhat does a steady red ERR illumination signify on the front plate during startup?\u003c\/h3\u003e\n\u003cp\u003eA solid red ERR lamp indicates a critical internal hardware fault or a corrupted firmware issue. If cycling the rack power does not clear the error, the module may need service or replacement.\u003c\/p\u003e\n\u003ch3\u003eDoes the module require external 24 V DC power wiring to function on the rack drop?\u003c\/h3\u003e\n\u003cp\u003eNo. The unit draws its operating power directly from the backplane bus. You do not need to wire any external power terminals to activate the device ports.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45014039625910,"sku":"BMENOS0300C","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BMENOS0300C_fd853679-7c27-43ed-84b2-7cb8e82da9a4.jpg?v=1780303394","url":"https:\/\/www.plcsparehub.com\/products\/bmenos0300c-modicon-x80-switch-module-schneider-electric-network","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}