{"product_id":"bently-nevada-990-04-70-01-05-990-vibration-transmitter","title":"Bently Nevada 990-04-70-01-05 | 990 Vibration Transmitter","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0070c0;\"\u003eBently Nevada 990-04-70-01-05\u003c\/strong\u003e is a \u003cstrong\u003e990 Series Vibration Transmitter\u003c\/strong\u003e designed for continuous machinery vibration monitoring.\u003c\/p\u003e\n\u003cp\u003eIt accepts signals from one \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e and its compatible extension cable. The transmitter converts shaft vibration measurements into a standard \u003cstrong\u003e4–20 mA DC output\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis two-wire configuration supports direct integration with PLC, DCS, and industrial monitoring systems. Maintenance teams can use the output for continuous vibration trending, alarm processing, and machinery condition assessment.\u003c\/p\u003e\n\u003cp\u003eThe 990 transmitter provides external zero and span adjustments. Its NOT OK signal defeat function also helps identify measurement-system faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #0070c0;\"\u003e\u003cstrong\u003e990-04-70-01-05\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e 990 Vibration Transmitter\u003cbr\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Made in U.S.A.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e990-04-70-01-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Input\u003c\/td\u003e\n\u003ctd\u003eOne 3300 NSv Proximity Probe and extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0–4 mils peak-to-peak (0–100 μm pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC, two-wire configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 6,000 Hz (+0, −3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5% of specified full-scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Adjustment\u003c\/td\u003e\n\u003ctd\u003eExternal adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan Adjustment\u003c\/td\u003e\n\u003ctd\u003eExternal adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Gap\u003c\/td\u003e\n\u003ctd\u003e0.5–1.75 mm (20–55 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Diameter\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (0.375 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 VDC at transmitter terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply for Specified Hazardous-Area Configuration\u003c\/td\u003e\n\u003ctd\u003e28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1,000 Ω at 35 VDC, including cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOT OK Output Response\u003c\/td\u003e\n\u003ctd\u003eBelow 3.6 mA within 100 μs after a NOT OK condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Recovery\u003c\/td\u003e\n\u003ctd\u003e2–3 seconds after the NOT OK condition clears\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Output Cable Distance\u003c\/td\u003e\n\u003ctd\u003eMaximum 3 m (10 ft) at the BNC connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e7.0 m (23.0 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Weight\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Number Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ordering code identifies the measurement range, system length, mounting arrangement, and agency approval configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003e990 Series Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0–4 mils pp (0–100 μm pp) full-scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003e7.0 m (23.0 ft) system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail mounting clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA Division 2, ATEX Zone 0, ATEX Zone 2, and ABS maritime approval configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Model:\u003c\/strong\u003e \u003cspan style=\"color: #0070c0;\"\u003e\u003cstrong\u003e990-04-70-01-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Performance and Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e The 0–100 μm pp range supports shaft vibration monitoring within the selected full-scale configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e The 5 Hz–6 kHz bandwidth supports vibration measurements across a broad operating frequency range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Accuracy:\u003c\/strong\u003e The loop accuracy is ±1.5% of the specified full-scale range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Resolution:\u003c\/strong\u003e The transmitter provides a continuous analog 4–20 mA signal. The manufacturer does not specify a digital resolution value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e The supplied specifications do not provide a separate linearity figure. Do not interpret loop accuracy as a standalone linearity specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e The system uses the compatible 3300 NSv probe's incremental scale factor. The supplied model information does not state a separate transmitter sensitivity value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Indication:\u003c\/strong\u003e The NOT OK function drives the output below 3.6 mA following a detected NOT OK condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Stability:\u003c\/strong\u003e External zero and span controls support field calibration and measurement adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. DIN Rail Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the transmitter using its specified 35 mm DIN rail clips.\u003c\/li\u003e\n\u003cli\u003eChoose a suitable control cabinet location with adequate access and ventilation.\u003c\/li\u003e\n\u003cli\u003eSecure the unit before connecting field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. Probe Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse one compatible \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e with its extension cable.\u003c\/li\u003e\n\u003cli\u003ePosition the probe perpendicular to the target surface.\u003c\/li\u003e\n\u003cli\u003eSet the probe gap between \u003cstrong\u003e0.5 and 1.75 mm\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfirm the target diameter reaches at least 9.5 mm.\u003c\/li\u003e\n\u003cli\u003eCheck the complete probe and extension cable configuration before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. Electrical Connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the transmitter to a suitable DC power supply.\u003c\/li\u003e\n\u003cli\u003eMaintain an input voltage between \u003cstrong\u003e+12 and +35 VDC\u003c\/strong\u003e at the transmitter terminals.\u003c\/li\u003e\n\u003cli\u003eWire the 4–20 mA output into the receiving PLC or DCS analog input.\u003c\/li\u003e\n\u003cli\u003eKeep the total loop resistance within 1,000 Ω at 35 VDC.\u003c\/li\u003e\n\u003cli\u003eFor the specified hazardous-area configuration, verify the required 28 V power supply arrangement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4. Cable Routing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKeep probe wiring away from high-voltage switching cables.\u003c\/li\u003e\n\u003cli\u003eUse suitable grounding and shielding practices for the installation.\u003c\/li\u003e\n\u003cli\u003eObserve the maximum 3 m cable distance for the Proximitor Sensor Output at the BNC connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInitial Commissioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the complete probe, extension cable, and transmitter combination.\u003c\/li\u003e\n\u003cli\u003eCheck the DC supply voltage at the transmitter terminals.\u003c\/li\u003e\n\u003cli\u003eConfirm the probe gap before applying operating conditions.\u003c\/li\u003e\n\u003cli\u003eMeasure the loop current and verify the expected 4–20 mA response.\u003c\/li\u003e\n\u003cli\u003eUse the external zero and span controls to establish the required measurement range.\u003c\/li\u003e\n\u003cli\u003eCheck the NOT OK response through an approved test procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRoutine Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect terminal connections for looseness or corrosion.\u003c\/li\u003e\n\u003cli\u003eCheck cable insulation and connector condition during scheduled maintenance.\u003c\/li\u003e\n\u003cli\u003eCompare transmitter readings with independent vibration measurements when investigating abnormal values.\u003c\/li\u003e\n\u003cli\u003eInvestigate output currents below 3.6 mA as potential NOT OK indications.\u003c\/li\u003e\n\u003cli\u003eVerify zero and span settings after probe replacement or maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e The NOT OK function provides a useful fault indication. However, technicians should inspect the entire measurement chain before replacing the transmitter.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 990-04-70-01-05\u003c\/strong\u003e requires a compatible 3300 NSv proximity measurement chain.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Compatibility:\u003c\/strong\u003e One 3300 NSv Proximity Probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtension Cable:\u003c\/strong\u003e Compatible 3300 NSv extension cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring Input:\u003c\/strong\u003e PLC, DCS, or monitoring equipment with a compatible 4–20 mA analog input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e +12 to +35 VDC at the transmitter terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Design:\u003c\/strong\u003e The complete circuit must remain within the specified 1,000 Ω maximum loop resistance at 35 VDC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Selection Consideration:\u003c\/strong\u003e The 7.0 m system length represents the specified probe measurement-chain configuration. Verify the actual probe and extension cable combination before ordering.\u003c\/p\u003e\n\u003cp\u003eDo not substitute a different probe family without confirming electrical compatibility, scale factor, system length, and calibration requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Environmental Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Division 2 hazardous-area approval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Zone 0 and Zone 2 approval configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eABS:\u003c\/strong\u003e Includes American Bureau of Shipping maritime approval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Made in U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Data:\u003c\/strong\u003e The supplied specifications do not state the operating temperature range, humidity limits, ingress protection rating, or vibration resistance of the transmitter enclosure. Confirm these values against the applicable manufacturer documentation before installation.\u003c\/p\u003e\n\u003cp\u003eFor hazardous-area applications, verify the complete installation against the equipment certification, wiring requirements, and applicable site regulations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging and Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Bently Nevada 990-04-70-01-05 Vibration Transmitter\u003c\/li\u003e\n\u003cli\u003e35 mm DIN rail mounting configuration\u003c\/li\u003e\n\u003cli\u003eProtective packaging suitable for transportation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Probe, extension cable, power supply, and additional accessories are not included unless the order explicitly specifies them.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFrom a machinery protection engineering perspective, the \u003cstrong\u003e990-04-70-01-05\u003c\/strong\u003e serves as a signal conditioning and transmission device for proximity-based vibration monitoring.\u003c\/p\u003e\n\u003cp\u003eIts 4–20 mA output simplifies integration with conventional industrial control systems. This arrangement allows operators to monitor vibration levels without requiring a dedicated proximity monitoring rack.\u003c\/p\u003e\n\u003cp\u003eThe 0–100 μm pp measurement range suits applications that require a defined vibration measurement span. The 5 Hz–6 kHz frequency response supports monitoring across multiple machinery operating conditions.\u003c\/p\u003e\n\u003cp\u003eOne important commissioning detail concerns the NOT OK output. A current below 3.6 mA indicates a measurement-system fault condition rather than an ordinary vibration reading.\u003c\/p\u003e\n\u003cp\u003eEngineers should therefore configure PLC or DCS logic to distinguish measurement faults from normal process alarms. This approach improves diagnostic reliability and reduces incorrect vibration assessments.\u003c\/p\u003e\n\u003cp\u003eBefore purchasing, confirm the probe family, system length, mounting code, and hazardous-area approval requirements. These details directly affect installation compatibility and commissioning results.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What does the Bently Nevada 990-04-70-01-05 measure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt measures shaft vibration through a compatible 3300 NSv Proximity Probe. It converts the measurement into a 4–20 mA analog output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What does the 04 code represent?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 04 code specifies a full-scale measurement range of 0–4 mils peak-to-peak, equivalent to 0–100 μm pp.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this transmitter connect directly to a PLC or DCS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Its two-wire 4–20 mA output supports compatible analog input channels. Check the receiving channel's loop power and resistance requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What does an output below 3.6 mA indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt indicates a NOT OK condition. The transmitter drives the output below 3.6 mA within 100 μs after detecting the condition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Why does the transmitter require a specific probe gap?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe gap affects the measurement operating point. Maintain 0.5–1.75 mm to support the specified full-scale measurement range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: Does the 7.0 m system length mean the BNC cable can extend 7 meters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 7.0 m system length identifies the specified probe measurement-chain configuration. The Proximitor Sensor Output cable distance has a separate 3 m maximum specification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ7: What should engineers check when the output remains below 3.6 mA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, inspect the probe, extension cable, power supply, and field wiring. Then check the probe gap and system compatibility. Replace components only after identifying the fault source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ8: How should buyers select the correct 990 transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the required full-scale range, probe family, system length, mounting arrangement, and certification requirements. Also confirm the receiving system's 4–20 mA input compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ9: Is this model suitable for hazardous-area applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIts specified approval configuration includes CSA Division 2, ATEX Zone 0, ATEX Zone 2, and ABS maritime approval. Verify the applicable certificate and installation conditions for the intended location.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ10: What information should buyers provide when requesting a quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete model number, required quantity, application, destination country, and any probe or cable requirements. This information helps verify configuration compatibility and quotation accuracy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada 990 Vibration Transmitter\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #0070c0;\"\u003e\u003cstrong\u003e990-04-70-01-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e supplies industrial automation components for machinery monitoring, process control, and equipment maintenance applications.\u003c\/p\u003e\n\u003cp\u003eContact our sales team for product pricing, availability, configuration verification, and delivery arrangements.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/990_Graphs_and_Figures_8ba4a14f-832f-4772-a484-c09fd48b12f9.png?v=1784875470\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013883125942,"sku":"990-04-70-01-05","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada990_2_2e5e7225-85e6-4575-aced-d698c35a0ff6.jpg?v=1793761864","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-990-04-70-01-05-990-vibration-transmitter","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}