{"product_id":"bently-nevada-9200-03-05-05-00-two-wire-velocity-seismoprobe","title":"Bently Nevada 9200-03-05-05-00 Two-Wire Velocity Seismoprobe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003eBently Nevada 9200\u003c\/span\u003e\u003c\/strong\u003e series serves as a high-performance solution for critical machinery vibration monitoring. This \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003e9200-03-05-05-00\u003c\/span\u003e\u003c\/strong\u003e Two-Wire Velocity Seismoprobe ensures precise seismic measurements in demanding industrial settings. Please refer to the official documentation for complete integration and calibration protocols.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003e9200-03-05-05-00\u003c\/span\u003e\u003c\/strong\u003e is built with the following specifications to ensure precise compatibility:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModel: \u003cstrong\u003e9200\u003c\/strong\u003e (Two-wire velocity transducer)\u003c\/li\u003e\n\u003cli\u003eMounting Angle\/Frequency: 03 (90 ±2.5 degrees, 4.5 Hz minimum)\u003c\/li\u003e\n\u003cli\u003eConnector Option: 05 (Terminal block top mount)\u003c\/li\u003e\n\u003cli\u003eMounting Base: 05 (1\/2-in 20 UNF-3A stud)\u003c\/li\u003e\n\u003cli\u003eAgency Approval: 00 (No special approvals required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: \u003cstrong\u003eBently Nevada\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePart Number: \u003cstrong\u003e9200-03-05-05-00\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensitivity: 20 mV\/mm\/s (500 mV\/in\/s) at 10 kΩ load\u003c\/li\u003e\n\u003cli\u003eFrequency Response: 4.5 Hz (270 cpm) minimum\u003c\/li\u003e\n\u003cli\u003eDynamic Range: 2.54 mm (0.100 in) peak-to-peak\u003c\/li\u003e\n\u003cli\u003eVelocity Range: 25 mm\/s (1 in\/s) at 100 Hz\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient: 0.2%\/°C\u003c\/li\u003e\n\u003cli\u003eCoil Resistance: 1.25 kΩ ±5%\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -29°C to +121°C (-20°F to +250°F)\u003c\/li\u003e\n\u003cli\u003eEnvironmental Protection: Dust and moisture resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003e9200\u003c\/strong\u003e probe securely to the machine casing for optimal signal path.\u003c\/li\u003e\n\u003cli\u003eApply correct torque to the mounting stud to ensure structural integrity.\u003c\/li\u003e\n\u003cli\u003eUse high-quality two-wire shielded cabling to eliminate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003ePerform annual inspections of the gasket to maintain environmental resistance.\u003c\/li\u003e\n\u003cli\u003eThe terminal block design facilitates rapid field maintenance and wiring checks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility and Applications\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003eBently Nevada 9200\u003c\/span\u003e\u003c\/strong\u003e series integrates perfectly with legacy and modern monitoring systems, including the 3500 and 3300 rack monitors. It is highly suited for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and Gas Turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps and Compressors\u003c\/li\u003e\n\u003cli\u003eIndustrial Fans and Blowers\u003c\/li\u003e\n\u003cli\u003eGearboxes and Motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB’s Insight\u003c\/h3\u003e\n\u003cp\u003eAs experts in automation, Global PLC Spare HUB recommends the \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003e9200-03-05-05-00\u003c\/span\u003e\u003c\/strong\u003e for its reliability and simplified two-wire architecture. This sensor provides critical diagnostic data essential for effective vibration trend analysis in rotating equipment.\u003c\/p\u003e\n\u003ch3\u003eLogistics and Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCondition: New and original in factory packaging.\u003c\/li\u003e\n\u003cli\u003eWarranty: 12 months comprehensive factory warranty.\u003c\/li\u003e\n\u003cli\u003eShipping: Expedited global delivery via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003eLead Time: Dispatch within 24-48 hours.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this sensor suitable for extreme vibration?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003e9200\u003c\/strong\u003e series is engineered specifically for high-vibration industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does mounting angle affect signal accuracy?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the 03 option requires a 90-degree orientation to meet calibration specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I select the right configuration?\u003c\/strong\u003e\u003cbr\u003eA: Always verify your machine casing stud size (05 equals 1\/2-in 20 UNF-3A) before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this at temperatures above 121°C?\u003c\/strong\u003e\u003cbr\u003eA: For temperatures up to 204°C, we recommend considering the 74712 series variant.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/9200_74712_Graphs_and_Figures.png?v=1775025635\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013929066678,"sku":"9200-03-05-05-00","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/Bently920074712_3.jpg?v=1780037519","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-9200-03-05-05-00-two-wire-velocity-seismoprobe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}