{"product_id":"bently-nevada-46000-01-magnetic-base-for-velomitor-transducers","title":"Bently Nevada 46000-01 Magnetic Base for Velomitor Transducers","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 46000-01\u003c\/span\u003e\u003c\/strong\u003e magnetic base delivers secure temporary mounting for \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eVelomitor\u003c\/span\u003e\u003c\/strong\u003e vibration sensors.\u003c\/p\u003e\n\u003cp\u003eThis high-strength adapter features a standard 1\/4-28 UNF thread connection for seamless mounting integration.\u003c\/p\u003e\n\u003cp\u003ePlant engineers utilize this mounting solution to conduct quick machinery diagnostics without permanent drilling.\u003c\/p\u003e\n\u003cp\u003eThe robust construction ensures stable signal transmission during critical vibration measurement passes.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features \u0026amp; Mechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe table below outlines the core technical parameters for the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 46000-01\u003c\/span\u003e\u003c\/strong\u003e magnetic mount.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e46000-01\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eVelomitor Transducer Accessories\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF female thread adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePull Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 lbs (200 N) vertical magnetic holding force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBroadband industrial machinery vibration measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlat response up to 1,000 Hz (60,000 CPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity Transmission\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect mechanical coupling with minimal signal damping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity \u0026amp; Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePreserves sensor native linearity and sub-micron resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +121°C (-40°F to +250°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCorrosion-resistant stainless steel body with industrial magnet core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterference Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsolated magnet design minimizes stray electromagnetic field noise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 330500 Velomitor\u003c\/span\u003e\u003c\/strong\u003e Piezo-velocity sensors.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eVelomitor CT\u003c\/span\u003e\u003c\/strong\u003e and high-temperature accelerometer variants.\u003c\/li\u003e\n\u003cli\u003eFits electric motor bearing housings, gearbox casings, and centrifugal pumps.\u003c\/li\u003e\n\u003cli\u003eSupports portable data collectors during walk-around predictive maintenance routes.\u003c\/li\u003e\n\u003cli\u003eIdeal for temporary vibration assessment on balance-of-plant rotating equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation, Commissioning \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClean the target metal surface to remove paint chips, rust, and oil debris.\u003c\/li\u003e\n\u003cli\u003eThread the 1\/4-28 UNF stud tightly into the magnetic base top socket.\u003c\/li\u003e\n\u003cli\u003eAttach the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eVelomitor\u003c\/span\u003e\u003c\/strong\u003e sensor hand-tight onto the adapter stud.\u003c\/li\u003e\n\u003cli\u003eGently roll the magnet onto the flat machinery casing to avoid sensor shock.\u003c\/li\u003e\n\u003cli\u003eWipe the magnetic face clean after every measurement pass to prevent particle buildup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance, Warranty \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e Manufactured under ISO 9001 quality management procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage List:\u003c\/strong\u003e One \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 46000-01\u003c\/span\u003e\u003c\/strong\u003e magnetic base with thread adapter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Full 12-month operational warranty against manufacturing defects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Time:\u003c\/strong\u003e Ships within 24 to 48 hours from order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Shipping:\u003c\/strong\u003e Express delivery via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eDHL\u003c\/strong\u003e, and \u003cstrong\u003eUPS\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSelection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eChoose permanent stud mounting for continuous machine protection and critical safety shutdown systems.\u003c\/p\u003e\n\u003cp\u003eChoose the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e46000-01\u003c\/span\u003e\u003c\/strong\u003e magnetic base when conducting temporary diagnostics across multiple machines.\u003c\/p\u003e\n\u003cp\u003eEnsure the mounting surface is ferrous metal with at least 1.5 inches of flat area.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Can I leave the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 46000-01\u003c\/span\u003e\u003c\/strong\u003e installed permanently on hot turbines?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Continuous exposure above 121°C degrades magnet strength over time. Use permanent studs for high-temperature continuous monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How do magnetic bases affect high-frequency vibration signal readings?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Magnetic bases reduce resonant frequency compared to solid stud mounting. Frequency response remains accurate up to 1 kHz for standard velocity checks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What causes inconsistent vibration readings during route monitoring?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Curved surfaces or dirt under the magnet reduce contact area. Always clean the surface and place the magnet flat on smooth metal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Does the magnet interfere with internal \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eVelomitor\u003c\/span\u003e\u003c\/strong\u003e electronics?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The stainless steel housing shields internal piezoelectric elements from magnetic flux interference during operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45282256814262,"sku":"46000-01","price":102.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/46000-01.jpg?v=1784879727","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-46000-01-magnetic-base-for-velomitor-transducers","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}