{"product_id":"bently-nevada-330909-05-30-05-02-00-3300-nsv-proximity-probe-request-a-quote","title":"Bently Nevada 330909-05-30-05-02-00 3300 NSv Proximity Probe | Request a Quote","description":"\u003cdiv\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003e330909-05-30-05-02-00\u003c\/strong\u003e\u003c\/span\u003e belongs to the advanced \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e series. Engineers deploy this proximity probe for precision vibration and position measurements in industrial machinery. The \u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003e330909\u003c\/strong\u003e\u003c\/span\u003e model features a robust \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3\/8-24 UNF\u003c\/strong\u003e\u003c\/span\u003e thread with integrated armor for superior mechanical protection. It accurately captures dynamic signals in confined spaces and harsh environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003e330909-05-30-05-02-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e Proximity Sensor Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 metre (20 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot required (\u003cstrong\u003e00\u003c\/strong\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 ± 0.5 ohms (center to outer conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Sealing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViton O-ring differential pressure seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 to 150 g (0.5 to 5.3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThread the \u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003e330909\u003c\/strong\u003e\u003c\/span\u003e probe into the mounting hole carefully.\u003c\/li\u003e\n\u003cli\u003eApply recommended torque of \u003cstrong\u003e11.3 N•m (100 in•lb)\u003c\/strong\u003e for standard \u003cstrong\u003e3\/8-24\u003c\/strong\u003e cases.\u003c\/li\u003e\n\u003cli\u003eLimit first three threads torque to \u003cstrong\u003e7.5 N•m (66 in•lb)\u003c\/strong\u003e to prevent thread distortion.\u003c\/li\u003e\n\u003cli\u003eEnsure maximum thread engagement does not exceed \u003cstrong\u003e0.563 in\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eRoute the fluoroethylene propylene (FEP) insulated cable away from high-voltage lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify DC resistance matches \u003cstrong\u003e4.0 ± 0.5 ohms\u003c\/strong\u003e prior to system startup.\u003c\/li\u003e\n\u003cli\u003eInspect the ClickLoc connector for secure mechanical locking.\u003c\/li\u003e\n\u003cli\u003eAvoid exposing the probe tip to temperatures below \u003cstrong\u003e-34°C (-30°F)\u003c\/strong\u003e during operation to protect the Viton O-ring pressure seal.\u003c\/li\u003e\n\u003cli\u003ePerform routine calibration checks using standard vibration simulators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFully compatible with \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e monitoring systems and proximitor sensors.\u003c\/li\u003e\n\u003cli\u003eProvides high-resolution gap voltage measurements for shaft radial vibration and axial position.\u003c\/li\u003e\n\u003cli\u003eEnables early fault detection of radial preload issues and rotor dynamic anomalies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured in the U.S.A. to strict quality standards.\u003c\/li\u003e\n\u003cli\u003eBacked by a comprehensive \u003cstrong\u003e12-month warranty\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eComplies with industrial durability requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFast order processing within \u003cstrong\u003e24-48 hours\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eGlobal shipping supported via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003e330909-05-30-05-02-00\u003c\/strong\u003e\u003c\/span\u003e Proximity Probe\u003c\/li\u003e\n\u003cli\u003eIntegrated Armor and ClickLoc Connector Cable\u003c\/li\u003e\n\u003cli\u003eFactory Specification Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBuying Guide and Selection Tips\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify your mounting thread size matches the \u003cstrong\u003e3\/8-24 UNF\u003c\/strong\u003e specification before ordering.\u003c\/li\u003e\n\u003cli\u003eConfirm total probe length requirements match your machinery casing depth.\u003c\/li\u003e\n\u003cli\u003eSelect armored variants when cables face severe mechanical abrasion risks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What causes premature pressure seal failure in the \u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003e330909\u003c\/strong\u003e\u003c\/span\u003e probe?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Exposing the probe to temperatures below \u003cstrong\u003e-34°C (-30°F)\u003c\/strong\u003e for sustained periods degrades the Viton O-ring seal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How do field engineers verify probe health during commissioning?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Technicians measure DC resistance from the center conductor to the outer conductor, expecting a baseline of \u003cstrong\u003e4.0 ± 0.5 ohms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Can the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e\u003c\/span\u003e system operate in high-temperature environments?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Yes, the probe withstands continuous operating temperatures up to \u003cstrong\u003e+177°C (+351°F)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eField engineers frequently encounter high vibration readings caused by loose mounting threads on proximity probes. Global PLC Spare HUB recommends strictly adhering to the \u003cstrong\u003e11.3 N•m\u003c\/strong\u003e torque specification during installation. Maintaining proper mechanical preload prevents false vibration spikes and extends sensor lifespan in critical turbomachinery applications.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330909_987d0827-8363-481e-b6e2-b08d406fcd97.png?v=1778832827\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013968978102,"sku":"330909-05-30-05-02-00","price":216.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330909_5_f03b9663-7294-41eb-8ed9-ff9e14c46edc.jpg?v=1788493628","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-330909-05-30-05-02-00-3300-nsv-proximity-probe-request-a-quote","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}