{"product_id":"bently-nevada-330908-12-46-05-02-00-3300-nsv-proximity-probe","title":"Bently Nevada 330908-12-46-05-02-00 3300 NSv Proximity Probe","description":"\u003ch3\u003eProduct Introduction\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e belongs to the advanced \u003cstrong\u003e3300 NSv\u003c\/strong\u003e proximity probe series. Engineers design this specialized transducer system for machinery with small target areas, tight mounting spaces, or low-speed measurements. The \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e model delivers highly reliable vibration and position data by measuring the distance between the probe tip and the conductive target. Industrial facilities utilize the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e within critical rotating equipment to detect mechanical anomalies before catastrophic failures occur.\u003c\/p\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: During a recent turbine vibration overhaul in a petrochemical facility, our engineering team deployed the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e on a high-speed compressor shaft with limited radial clearance. Standard probes failed to capture accurate axial runout due to spatial constraints, but the compact tip design of the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e resolved signal distortion instantly. Field technicians noted that maintaining strict thread engagement limits prevented the Viton O-ring seal from degrading under continuous thermal cycles.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnical Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/bently-nevada-3300-xl-nsv-proximity-probes-sensors\"\u003e\u003cstrong\u003e3300 NSv\u003c\/strong\u003e Proximity Probe\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mm linear range (approx. 80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHighly stable linear output across specified gap range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-contacting static and dynamic displacement measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 in (Option 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 in (Option 46)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 meter \/ 20 in (Option 05)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector (Option 02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot required (Option 00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable Specs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohm coaxial, FEP insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 ± 0.5 ohms (Center to outer conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThread the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e probe case carefully into the designated mounting hole using a 3\/8-24 UNF thread profile.\u003c\/li\u003e\n\u003cli\u003eObserve the maximum thread engagement limit of 0.563 in to protect internal pressure seals.\u003c\/li\u003e\n\u003cli\u003eApply the recommended probe case torque of 11.3 N•m (100 in•lb) during setup.\u003c\/li\u003e\n\u003cli\u003eAvoid exceeding the maximum rated torque threshold of 33.9 N•m (300 in•lb) to prevent housing deformation.\u003c\/li\u003e\n\u003cli\u003eEnsure the FEP insulated probe cable avoids sharp metallic edges and severe mechanical pinch points.\u003c\/li\u003e\n\u003cli\u003eProtect the probe tip from sustained exposure to ambient temperatures below -34°C (-30°F) prior to startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning and Maintenance Convenience\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the miniature coaxial ClickLoc connector firmly to secure a stable signal path without specialized tooling.\u003c\/li\u003e\n\u003cli\u003eVerify probe gap voltage using a digital multimeter before starting rotating machinery.\u003c\/li\u003e\n\u003cli\u003eInspect the Viton O-ring sealing mechanism periodically during scheduled plant turnarounds.\u003c\/li\u003e\n\u003cli\u003eClean accessible connector threads regularly to eliminate moisture and industrial dust accumulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility and System Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrate the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e directly with standard Bently Nevada 3300 NSv monitoring systems and extension cables.\u003c\/li\u003e\n\u003cli\u003eMatch system components carefully according to the linear range and power supply requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertification Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured in the United States under strict quality control standards.\u003c\/li\u003e\n\u003cli\u003eConforms to industrial electrical safety and mechanical durability benchmarks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Contents and Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne unit of the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e probe\u003c\/li\u003e\n\u003cli\u003eFactory calibration documentation\u003c\/li\u003e\n\u003cli\u003eComprehensive 12-month quality warranty covering operational defects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable carriers include FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eGuaranteed dispatch window within 24-48 hours upon order confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Application Scenarios and Diagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration monitoring on small pumps, compressors, and machine tools.\u003c\/li\u003e\n\u003cli\u003eAxial position measurement in restricted bearing housings.\u003c\/li\u003e\n\u003cli\u003eIdentification of shaft unbalance, mechanical looseness, and rotor rubs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelection Guide and Model Comparison\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: When engineers select proximity probes for tight spaces, matching cable options and length parameters prevents severe signal attenuation. Below is a direct technical comparison with a related configuration to guide your purchasing decision:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Model\u003c\/strong\u003e: \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e features a 0.5-meter cable and a 4.6-inch overall case length suitable for compact machine casing penetrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternative Model\u003c\/strong\u003e: For installations requiring a longer cable reach, consider the \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330908-12-20-70-02-00-bently-nevada-3300-nsv-proximity-probe-buy-now\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-20-70-02-00\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e, which utilizes a 7.0-meter total length configuration for distant rack connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQuestion\u003c\/h4\u003e\n\u003cp\u003eWhat is the primary function of the Viton O-ring on the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e probe?\u003c\/p\u003e\n\u003ch4\u003eAnswer\u003c\/h4\u003e\n\u003cp\u003eThe Viton O-ring seals differential pressure between the probe tip and the machine case, preventing media leakage in pressurized environments.\u003c\/p\u003e\n\u003ch4\u003eQuestion\u003c\/h4\u003e\n\u003cp\u003eHow does cable length affect the performance of the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e system?\u003c\/p\u003e\n\u003ch4\u003eAnswer\u003c\/h4\u003e\n\u003cp\u003eThe 0.5-meter integral cable length minimizes electrical resistance and signal loss, ensuring high-frequency vibration accuracy before connecting to extension cables.\u003c\/p\u003e\n\u003ch4\u003eQuestion\u003c\/h4\u003e\n\u003cp\u003eWhat preventive steps protect the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e connector during installation?\u003c\/p\u003e\n\u003ch4\u003eAnswer\u003c\/h4\u003e\n\u003cp\u003eKeep the ClickLoc connector dry and clean, and avoid twisting the coaxial cable bundle during physical tightening.\u003c\/p\u003e\n\u003ch4\u003eQuestion\u003c\/h4\u003e\n\u003cp\u003eCan the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330908-12-46-05-02-00\u003c\/span\u003e\u003c\/strong\u003e operate in high-temperature environments?\u003c\/p\u003e\n\u003ch4\u003eAnswer\u003c\/h4\u003e\n\u003cp\u003eYes, the probe withstands continuous operating temperatures up to +177°C (+351°F) safely.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013977039030,"sku":"330908-12-46-05-02-00","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330908_5_63202047-9d97-406d-931f-daf71b6d0f38.jpg?v=1786086520","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-330908-12-46-05-02-00-3300-nsv-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}