{"product_id":"bently-nevada-330908-12-36-05-02-00-nsv-proximity-sensor-probe","title":"Bently Nevada 330908-12-36-05-02-00 NSv Proximity Sensor Probe","description":"\u003ch3 style=\"font-weight: bold;\"\u003eEngineering Architecture \u0026amp; Transducer Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330908-12-36-05-02-00\u003c\/strong\u003e\u003c\/span\u003e is a precision-engineered 3300 NSv proximity probe designed specifically for machinery management systems requiring high-accuracy radial vibration and axial position measurements on small or high-speed shafts. Built with an AISI304 stainless steel case and a polyphenylene sulfide (PPS) probe tip, this transducer withstands severe thermal and mechanical stresses. It incorporates a 75-ohm FEP-insulated coaxial cable terminated with a miniature ClickLoc connector, ensuring signal integrity across high-electromagnetic industrial environments.\u003c\/p\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: During a critical startup phase on a high-speed centrifugal compressor train at an oil refinery in Alberta, our instrumentation team utilized the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330908-12-36-05-02-00\u003c\/strong\u003e\u003c\/span\u003e probe to monitor micro-vibrations near the thrust bearing. Because NSv transducers are purpose-built for low-range linear applications such as partial-admission steam turbines and small gearboxes, this probe delivered clean, noise-free gap voltage signals where standard probes suffered from saturation limits.\u003c\/p\u003e\n\u003ch3 style=\"font-weight: bold;\"\u003eModel Configuration Breakdown \u0026amp; Suffix Architecture\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%; border-color: #ddd;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003cth style=\"text-align: left;\"\u003ePart Segment\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eDesignator\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eEngineering Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330908\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Probe Platform, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e1.2 inches of smooth unthreaded case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e3.6 inches total structural probe case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 meter (20 in) integrated coaxial cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector \u0026amp; Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with standard FEP cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required \/ Standard commercial baseline release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-weight: bold;\"\u003eCore Technical Specifications \u0026amp; Limits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Materials:\u003c\/strong\u003e AISI304 stainless steel probe case with rugged Polyphenylene Sulfide (PPS) tip\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Resistance:\u003c\/strong\u003e Center conductor to outer shield DC resistance measures $4.0 \\pm 0.5\\text{ ohms}$ for a $0.5\\text{m}$ cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Maximum rated torque of $33.9\\text{ N}\\cdot\\text{m}$ ($300\\text{ in}\\cdot\\text{lb}$); recommended installation torque of $11.3\\text{ N}\\cdot\\text{m}$ ($100\\text{ in}\\cdot\\text{lb}$)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Maximum allowable thread engagement length of $0.563\\text{ in}$ for 3\/8-24 UNF threads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating \u0026amp; Storage Thermal Range:\u003c\/strong\u003e $-52^\\circ\\text{C}$ to $+177^\\circ\\text{C}$ ($-62^\\circ\\text{F}$ to $+351^\\circ\\text{F}$)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Sealing:\u003c\/strong\u003e Viton O-ring seal designed to contain differential pressure between probe tip and case; weight ranges from $14\\text{ to }150\\text{ g}$\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-weight: bold;\"\u003eTarget Machinery \u0026amp; Industrial Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Turbomachinery:\u003c\/strong\u003e Radial vibration monitoring on centrifugal compressors, turbo-expanders, and specialized multi-stage pumps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecialized Gearboxes:\u003c\/strong\u003e Precision shaft position and axial displacement tracking on high-reduction industrial gear drives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall Machinery Trains:\u003c\/strong\u003e Applications where physical shaft clearance restricts the use of standard 3300 XL proximity probes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Steam and gas turbine monitoring networks requiring high linear range compliance on small-diameter journals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-weight: bold;\"\u003eLogistics, Warranty \u0026amp; Fulfillment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Fully protected by a comprehensive 12-month manufacturer warranty covering material defects and workmanship.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Delivery Network:\u003c\/strong\u003e Fast and secure worldwide transportation dispatched via premium couriers including FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing Lead Time:\u003c\/strong\u003e Standard stock items undergo strict quality verification and ship within 24 to 48 hours of order confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"font-weight: bold;\"\u003eProfessional Frequently Asked Questions \u0026amp; Buying Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What specific mechanical advantage does the NSv design provide over standard proximity probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The NSv design features specialized tip and internal circuitry tuning that delivers an extended linear measurement range for small-shaft applications, preventing signal clipping in tight radial spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Purchasing Guidance: How do I select the correct case length and unthreaded portion for replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Match the exact depth of your existing machinery mounting hole; the unthreaded length (1.2 inches for code 12) ensures proper clearance through guide sleeves, while the overall length (3.6 inches for code 36) dictates total housing reach.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What strict precaution must technicians follow regarding low-temperature installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Avoid exposing the probe tip and Viton O-ring seal to temperatures below -34°C (-30°F) for sustained periods during handling, as extreme cold can compromise pressure seal integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is maintaining the recommended installation torque of 11.3 N·m critical?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Applying the recommended torque prevents thread galling in stainless steel mounting holes while ensuring the Viton O-ring forms a reliable pressure-tight seal without distorting the probe case geometry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What diagnostic check should be performed if probe DC resistance reads outside the 4.0 ohms baseline?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Disconnect the ClickLoc connector and inspect the center pin and outer shield for moisture contamination, micro-fractures in the FEP cable jacket, or internal conductor short circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330901-330910_432da41b-a3bf-4c98-a960-7a1ed65c995c.png?v=1782895913\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013976940726,"sku":"330908-12-36-05-02-00","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330908.jpg?v=1787731097","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-330908-12-36-05-02-00-nsv-proximity-sensor-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}