{"product_id":"bently-nevada-330905-05-08-10-01-05-3300-nsv-probe","title":"Bently Nevada 330905-05-08-10-01-05 3300 NSv Probe","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #1677c8;\"\u003eBently Nevada 330905-05-08-10-01-05\u003c\/span\u003e\u003c\/strong\u003e is a \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e designed for non-contact shaft displacement and vibration measurements. It uses eddy-current technology to monitor conductive targets in rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThis configuration features an \u003cstrong\u003eM10 × 1 mounting thread\u003c\/strong\u003e, a 50 mm unthreaded section, an 80 mm overall case length, and a 1.0 m probe cable. The standard FEP-insulated cable terminates in a miniature coaxial ClickLoc connector with a connector protector.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3300 NSv series\u003c\/strong\u003e supports machinery monitoring where installation space, target geometry, and environmental resistance influence sensor selection. Its chemical resistance improves suitability for many process compressor applications compared with the earlier 3300 RAM probe.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 3300 NSv Proximity Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cspan style=\"color: #1677c8;\"\u003e\u003cstrong\u003e330905-05-08-10-01-05\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New and original, factory packing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, UPS, or DHL; dispatch within 24–48 hours after order confirmation, subject to stock verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 NSv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330905-05-08-10-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor principle\u003c\/td\u003e\n\u003ctd\u003eEddy-current proximity measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting thread\u003c\/td\u003e\n\u003ctd\u003eM10 × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe armor\u003c\/td\u003e\n\u003ctd\u003eWithout armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded length\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall case length\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal probe cable length\u003c\/td\u003e\n\u003ctd\u003e1.0 m (39 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable construction\u003c\/td\u003e\n\u003ctd\u003eStandard 75 Ω coaxial cable, FEP insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe tip material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe case material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear measurement range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear operating interval\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.25–1.75 mm (10–70 mils) from the target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended gap setting\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental scale factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale factor tolerance\u003c\/td\u003e\n\u003ctd\u003e+12.5% \/ −20%, including interchangeability error under specified test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity deviation\u003c\/td\u003e\n\u003ctd\u003eLess than ±0.06 mm (±2.3 mils) from the best-fit straight line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency response\u003c\/td\u003e\n\u003ctd\u003e0–10 kHz, +0\/−3 dB typical, with up to 305 m of field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance\u003c\/td\u003e\n\u003ctd\u003e4.2 ± 0.5 Ω, center conductor to outer conductor, for the 1.0 m probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension cable capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft), typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension cable resistance\u003c\/td\u003e\n\u003ctd\u003eCenter conductor: 0.220 Ω\/m; shield: 0.066 Ω\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−52°C to +177°C (−62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e−52°C to +177°C (−62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum bend radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended installation torque\u003c\/td\u003e\n\u003ctd\u003eFinger-tight for the probe mounting case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum connector torque\u003c\/td\u003e\n\u003ctd\u003e0.56 N·m (5 in·lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum thread engagement\u003c\/td\u003e\n\u003ctd\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approval option\u003c\/td\u003e\n\u003ctd\u003e05 — Multiple Approvals; verify the applicable approval documents for the exact assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eResolution clarification:\u003c\/strong\u003e The manufacturer specifications provided here do not establish a standalone resolution value. Actual measurement resolution depends on the complete transducer chain, monitor electronics, signal conditioning, and acquisition settings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Code Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode segment\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003cth\u003eSelected configuration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330905\u003c\/td\u003e\n\u003ctd\u003eProbe family and mounting thread\u003c\/td\u003e\n\u003ctd\u003eM10 × 1, unarmored 3300 NSv probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eUnthreaded length\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eOverall case length\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eTotal probe cable length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eConnector and cable option\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector with protector and standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eAgency approval option\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Measurement Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaft vibration monitoring:\u003c\/strong\u003e Measures dynamic changes in the gap between the probe tip and a conductive shaft target.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaft displacement monitoring:\u003c\/strong\u003e Supports relative shaft vibration measurements when paired with a compatible signal conditioner and monitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAxial position monitoring:\u003c\/strong\u003e Helps track shaft movement when the target geometry and system configuration support the required measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance-related monitoring:\u003c\/strong\u003e Provides gap-dependent signals for engineering assessment of shaft position and movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-frequency signal response:\u003c\/strong\u003e Supports dynamic measurements within the specified 0–10 kHz response range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe probe provides a measurement signal rather than an independent diagnostic report. A compatible monitor interprets that signal alongside alarm limits, operating conditions, and other machine measurements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003cth\u003eEngineering purpose\u003c\/th\u003e\n\u003cth\u003eField consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess gas compressors\u003c\/td\u003e\n\u003ctd\u003eMonitor shaft vibration and relative movement\u003c\/td\u003e\n\u003ctd\u003eCheck gas compatibility, mounting access, and target material.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCentrifugal compressors\u003c\/td\u003e\n\u003ctd\u003eSupport condition monitoring of rotating shafts\u003c\/td\u003e\n\u003ctd\u003eConfirm shaft diameter and probe mounting clearance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigeration compressors\u003c\/td\u003e\n\u003ctd\u003eTrack changes in shaft vibration during operation\u003c\/td\u003e\n\u003ctd\u003eVerify the environmental conditions and sensor compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial rotating machinery\u003c\/td\u003e\n\u003ctd\u003eProvide proximity signals for machinery protection systems\u003c\/td\u003e\n\u003ctd\u003eConfirm the required measurement direction and monitor input.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the mounting location.\u003c\/strong\u003e Confirm the M10 × 1 thread and available 80 mm case length before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the target surface.\u003c\/strong\u003e Check shaft condition, target material, runout, and available clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtect the probe cable.\u003c\/strong\u003e Maintain the specified 25.4 mm minimum bend radius and avoid sharp edges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall the probe carefully.\u003c\/strong\u003e Follow the machine manufacturer's mounting procedure and avoid excessive tightening force.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the signal chain.\u003c\/strong\u003e Use the specified ClickLoc connection and compatible NSv extension cable and Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute field wiring correctly.\u003c\/strong\u003e Use shielded three-conductor triad cable where required by the system design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the installation.\u003c\/strong\u003e Confirm the gap voltage, signal polarity, cable integrity, and monitor channel response before operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eWiring limit:\u003c\/strong\u003e The specified maximum field wiring length between the 3300 XL NSv Proximitor Sensor and monitor is 305 m (1,000 ft). Longer wiring can reduce high-frequency response.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap adjustment:\u003c\/strong\u003e Use the recommended 1.0 mm gap as the initial setup reference, then verify the system's specified voltage and calibration procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal verification:\u003c\/strong\u003e Compare static gap voltage and dynamic signal behavior against approved commissioning records.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector inspection:\u003c\/strong\u003e Check the ClickLoc connector for secure engagement, contamination, and physical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable inspection:\u003c\/strong\u003e Look for cuts, excessive bending, abrasion, and shield damage during scheduled maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrend analysis:\u003c\/strong\u003e Compare vibration amplitude, shaft position, and operating conditions against established machine baselines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault isolation:\u003c\/strong\u003e Check the probe, extension cable, Proximitor sensor, monitor input, and grounding path before replacing components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eField example:\u003c\/strong\u003e A compressor channel shows an unexpected vibration increase after maintenance. First, inspect probe clearance, connector engagement, cable routing, and target condition. Then compare the static gap voltage and signal trend with commissioning records. This sequence helps distinguish installation problems from actual machine changes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Interchangeability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv probe is mechanically and electrically compatible with the previous 3300 RAM probe and extension cable system, according to the supplied product information. Confirm the complete installed system before replacement.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse a compatible \u003cstrong\u003e3300 NSv Proximitor sensor\u003c\/strong\u003e and the specified extension cable.\u003c\/li\u003e\n\u003cli\u003eVerify the total electrical length and cable configuration required by the installed transducer system.\u003c\/li\u003e\n\u003cli\u003eDo not assume compatibility with other Bently Nevada proximity probe families based only on connector appearance.\u003c\/li\u003e\n\u003cli\u003eCheck the monitor input requirements, scale factor, target material, and calibration settings before commissioning.\u003c\/li\u003e\n\u003cli\u003eVerify approval requirements against the installed equipment documentation and the exact product marking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Selection Comparison\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCompare the requested probe with the following alternative before ordering. The two part numbers share the 330905 M10 × 1 probe family, but their configuration codes differ.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection item\u003c\/th\u003e\n\u003cth\u003eCurrent model\u003c\/th\u003e\n\u003cth\u003eAlternative model\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330905-05-08-10-01-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330905-05-13-05-12-00-3300-nsv-proximity-sensor-by-bently-nevada\"\u003e\u003cstrong\u003e330905-05-13-05-12-00\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eM10 × 1\u003c\/td\u003e\n\u003ctd\u003eM10 × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded length\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall case length\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003ctd\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal probe cable length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector and cable\u003c\/td\u003e\n\u003ctd\u003eClickLoc with protector; standard cable\u003c\/td\u003e\n\u003ctd\u003eClickLoc without protector; FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval option\u003c\/td\u003e\n\u003ctd\u003e05 — Multiple Approvals\u003c\/td\u003e\n\u003ctd\u003e00 — Approval not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary selection factor\u003c\/td\u003e\n\u003ctd\u003eShorter case, longer cable, standard cable configuration\u003c\/td\u003e\n\u003ctd\u003eLonger case, shorter cable, FluidLoc configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical recommendation:\u003c\/strong\u003e Select the current model when the 80 mm case, 1.0 m cable, connector protector, and specified approval option match the installation requirements. Consider the alternative when the 130 mm case and 0.5 m FluidLoc cable match the mounting and cable-routing constraints. Confirm the exact suffix, electrical compatibility, and approval requirements before substitution.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Resistance and Installation Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe PPS probe tip and stainless steel case support the specified industrial measurement configuration.\u003c\/li\u003e\n\u003cli\u003eThe NSv design offers improved chemical resistance compared with the 3300 RAM probe.\u003c\/li\u003e\n\u003cli\u003eThe rated operating temperature range is −52°C to +177°C.\u003c\/li\u003e\n\u003cli\u003eThe probe uses a Viton O-ring to seal differential pressure between the probe tip and case.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer does not pressure-test probes before shipment. Request a specific seal test when the application requires one.\u003c\/li\u003e\n\u003cli\u003eConfirm actual chemical exposure, process pressure, target material, and environmental conditions before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification and Approval Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ordering suffix \u003cstrong\u003e05\u003c\/strong\u003e identifies the Multiple Approvals option. It does not independently identify every applicable certification or hazardous-area classification.\u003c\/p\u003e\n\u003cp\u003eRequest the applicable approval documentation for the exact part number and intended installation. Verify regional requirements, hazardous-area classification, and equipment nameplate details before commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Shipping, and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada 3300 NSv proximity probe, part number 330905-05-08-10-01-05.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e New and original factory packing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded item:\u003c\/strong\u003e Probe assembly in the ordered configuration. Confirm any separately required extension cable or accessories before purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to the seller's confirmed warranty terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping carriers:\u003c\/strong\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch target:\u003c\/strong\u003e 24–48 hours after order confirmation, subject to verified stock and order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder support:\u003c\/strong\u003e Contact Global PLC Spare HUB to confirm availability, delivery arrangements, and configuration details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFrom a field engineering perspective, probe selection should begin with the installed transducer system rather than the mounting thread alone.\u003c\/p\u003e\n\u003cp\u003eFor example, an engineer replacing a compressor probe may find that both candidates use M10 × 1 threads. However, the longer case, shorter cable, and FluidLoc option can change installation access and cable-routing requirements.\u003c\/p\u003e\n\u003cp\u003eThe engineer should also confirm the complete transducer chain. Probe, extension cable, and Proximitor sensor characteristics must match the monitoring system's design. A physically compatible connector does not guarantee correct electrical performance.\u003c\/p\u003e\n\u003cp\u003eDuring troubleshooting, compare the static gap voltage with the commissioning baseline before interpreting vibration changes as mechanical faults. Inspect cable routing and connectors when readings change immediately after maintenance. Use independent machine measurements and operating data to confirm any suspected machinery condition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelection priority:\u003c\/strong\u003e Match the full part number, mounting dimensions, cable option, approval requirements, target material, and monitoring electronics before purchase.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What does the Bently Nevada 330905-05-08-10-01-05 measure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt measures the gap between the probe tip and a conductive target. A compatible transducer system converts this measurement into a signal for shaft vibration or displacement monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Can this probe connect directly to a PLC analog input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDo not connect the probe directly to a standard PLC analog input without the required interface. The probe requires a compatible Proximitor system to generate the appropriate measurement signal. Verify the PLC interface and signal-conditioning requirements before integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What should engineers check when vibration readings suddenly change?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, inspect probe clearance, connector seating, cable damage, and the target surface. Next, verify the static gap voltage and compare the signal with commissioning records. Finally, check the Proximitor sensor, monitor channel, and independent vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Does the 1.0 m probe cable eliminate the need for an extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot necessarily. The required total electrical length depends on the complete NSv transducer configuration. Confirm the specified extension cable and Proximitor combination before ordering or modifying the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Can the alternative 330905-05-13-05-12-00 replace this model directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot automatically. The alternative has a 130 mm case, a 0.5 m cable, a FluidLoc configuration, and a different approval option. Verify mechanical clearance, cable requirements, system compatibility, and certification needs before substitution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. What target size is recommended for reliable measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied specifications identify a minimum flat target diameter of 8.9 mm and a recommended minimum of 13 mm. Smaller shaft diameters can change the scale factor during axial position measurements. Verify the target geometry and consult the manufacturer's application guidance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. How should buyers verify the approval suffix?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the complete part number and product marking against the required site approvals. The suffix 05 indicates Multiple Approvals, but the exact certification scope requires confirmation through the relevant documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. What information should buyers provide when requesting a quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete part number, required quantity, delivery destination, and expected delivery date. Include the existing Proximitor model, extension cable length, mounting dimensions, and approval requirements when requesting a replacement recommendation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eContact \u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e for pricing, availability, and technical selection assistance for the \u003cstrong\u003e\u003cspan style=\"color: #1677c8;\"\u003eBently Nevada 330905-05-08-10-01-05\u003c\/span\u003e\u003c\/strong\u003e. Provide your existing system configuration to help confirm compatibility before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330901-330910_432da41b-a3bf-4c98-a960-7a1ed65c995c.png?v=1782895913\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013975662774,"sku":"330905-05-08-10-01-05","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330905-00-15-05-02-00_75a43562-a4bc-4728-af29-b1625cb4746c.jpg?v=1792463206","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-330905-05-08-10-01-05-3300-nsv-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}