{"product_id":"bently-nevada-330141-08-50-02-00-armored-proximity-sensor-probe","title":"Bently Nevada 330141-08-50-02-00 Armored Proximity Sensor Probe","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 330141-08-50-02-00\u003c\/strong\u003e\u003c\/span\u003e is a rugged \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL 8 mm Proximity Probe\u003c\/strong\u003e\u003c\/span\u003e designed for non-contact vibration and position measurements. Engineers use this eddy current transducer system on critical rotating machinery like turbines, compressors, and pumps.\u003c\/p\u003e\n\u003cp\u003eThis model features a 0.8-inch case length and flexible stainless steel armor. The internal polyphenylene sulfide tip encapsulation protects sensitive components from mechanical stress and harsh process fluids.\u003c\/p\u003e\n\u003cp\u003eIntegrated \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTipLoc\u003c\/strong\u003e\u003c\/span\u003e molding and \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eCableLoc\u003c\/strong\u003e\u003c\/span\u003e construction deliver up to 330 N cable pull strength. The system ensures precise shaft displacement tracking in severe industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Insights \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur field reliability team evaluates proximity probes in demanding power generation and petrochemical applications. The \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 3300 XL Series\u003c\/strong\u003e\u003c\/span\u003e consistently demonstrates superior mechanical resilience compared to legacy designs.\u003c\/p\u003e\n\u003cp\u003eDuring a recent gas turbine overhaul, technicians noticed severe cable fatigue on non-armored sensors due to high pipe vibration. Replacing them with the armored \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330141-08-50-02-00\u003c\/strong\u003e\u003c\/span\u003e eliminated false vibration spikes completely.\u003c\/p\u003e\n\u003cp\u003eThe patented \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eCableLoc\u003c\/strong\u003e\u003c\/span\u003e design prevents cable pull-out when technicians work in tight bearing housings. This feature significantly reduces accidental sensor damage during routine maintenance overhauls.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330141-08-50-02-00\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL 8 mm System\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Type:\u003c\/strong\u003e Proximity Probe with Armor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase Length:\u003c\/strong\u003e 0.8 inches (Unthreaded)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Cable Length:\u003c\/strong\u003e 5.0 meters (16.4 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e Miniature coaxial ClickLoc connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Option:\u003c\/strong\u003e Standard cable with armor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Range:\u003c\/strong\u003e 2.0 mm (80 mils)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale Factor (ISF):\u003c\/strong\u003e 7.87 V\/mm (200 mV\/mil) ± 5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Linear Deviation:\u003c\/strong\u003e Less than ±0.025 mm (±1 mil)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Resistance:\u003c\/strong\u003e 8.73 ± 0.50 Ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTip Material:\u003c\/strong\u003e Polyphenylene sulfide (PPS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase Material:\u003c\/strong\u003e AISI 303 or 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -52°C to +177°C (-62°F to +350°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals:\u003c\/strong\u003e Option 00 (Not required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330141-08-50-02-00\u003c\/strong\u003e\u003c\/span\u003e probe requires matching system components for accurate measurement scale factors. Always pair this 5-meter probe directly with a 5-meter \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eDo not use extension cables with a 5-meter probe configuration. Using an extension cable alters the total electrical length, causing severe calibration error across the linear range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the target material matches standard AISI 4140 steel calibration.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum probe tip clearance of 1.5 mm from surrounding metal walls.\u003c\/li\u003e\n\u003cli\u003eMount the probe securely using proper torque to prevent mechanical loosening.\u003c\/li\u003e\n\u003cli\u003eEnsure the armor jacket terminates outside any severe bend radius zones.\u003c\/li\u003e\n\u003cli\u003eClean coaxial connectors thoroughly before hand-tightening the ClickLoc mechanism.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSet the initial mechanical gap using a calibrated DC voltmeter connected to the Proximitor output. Adjust probe position until the gap voltage reaches approximately -9.0 VDC to achieve mid-scale positioning.\u003c\/p\u003e\n\u003cp\u003eInspect armor jackets periodically for physical crushing or excessive corrosion. Measure center-to-outer conductor DC resistance during turnarounds to verify the 8.73 Ohm baseline.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications \u0026amp; Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe excels at shaft radial vibration monitoring, axial thrust position measurement, and keyphasor speed sensing. It provides vital raw signals for machinery protection systems like \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e\u003c\/span\u003e racks.\u003c\/p\u003e\n\u003cp\u003eDiagnostic capabilities include detecting rotor unbalance, shaft misalignment, journal bearing wear, and oil whirl instabilities before catastrophic equipment failure occurs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSelection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelect your \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL Probe\u003c\/strong\u003e\u003c\/span\u003e based on specific physical geometry and required overall electrical length:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330101:\u003c\/strong\u003e 8 mm probe, 3\/8-24 UNF thread, unarmored.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e330102:\u003c\/strong\u003e 8 mm probe, 3\/8-24 UNF thread, armored.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e330140:\u003c\/strong\u003e 8 mm probe, smooth case without armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e330141:\u003c\/strong\u003e 8 mm probe, smooth case with protective armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength Selection:\u003c\/strong\u003e Choose 5.0m for direct connection without extension cables, or 1.0m when using standard 4.0m extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping, Warranty, \u0026amp; Package List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe process and dispatch orders within 24 to 48 hours via express air couriers including FedEx, UPS, and DHL worldwide.\u003c\/p\u003e\n\u003cp\u003eEvery shipment includes a comprehensive 12-month warranty covering manufacturing defects under standard operating conditions.\u003c\/p\u003e\n\u003cp\u003ePackage List: 1 x \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 330141-08-50-02-00 Proximity Probe\u003c\/strong\u003e\u003c\/span\u003e with protective connector cap and documentation sheet.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I connect this 5-meter probe to a 9-meter Proximitor sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No, matching system lengths is critical. A 5-meter probe must connect directly to a 5-meter Proximitor sensor to maintain accurate scale factors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Why does this probe feature armor cable protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The flexible stainless steel armor shields the inner cable from sharp conduit edges, hot surfaces, and mechanical impact in harsh plant areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What happens if ambient temperature drops below -34°C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Temperatures below -34°C (-30°F) do not stop probe operation, but they may cause premature failure of the internal Viton pressure seal.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330140_330141_330197_330198.png?v=1784785679\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How do I verify if the probe cable is damaged without specialized tools?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Check resistance with a digital multimeter between the center and outer conductor. A normal reading for this 5-meter model is approximately 8.73 Ohms.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45014035103926,"sku":"330141-08-50-02-00","price":248.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330140_3_abd3fb82-b2f9-480c-a1d9-a0b3c5937151.jpg?v=1784785702","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-330141-08-50-02-00-armored-proximity-sensor-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}