{"product_id":"bently-nevada-330140-08-15-02-00-3300-xl-8mm-proximity-probe","title":"Bently Nevada 330140-08-15-02-00 3300 XL 8mm Proximity Probe","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 330140-08-15-02-00\u003c\/strong\u003e\u003c\/span\u003e is a premium \u003cstrong\u003e3300 XL 8 mm Proximity Probe\u003c\/strong\u003e engineered for non-contact vibration and position measurements. Manufactured in the USA, this eddy current sensor features a 0.8-inch unthreaded case and a 1.5-meter continuous cable. It includes a ClickLoc coaxial connector to ensure stable signal transmission on critical industrial rotating machinery.\u003c\/p\u003e\n\u003cp\u003eEngineering upgrades make the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL Series\u003c\/strong\u003e\u003c\/span\u003e exceptionally durable in harsh plant environments. The patented TipLoc molding reinforces the bond between the probe tip and body. Additionally, the CableLoc design provides 330 N (75 lbf) of pull strength. The 8 mm molded PPS plastic tip offers superior mechanical protection against harsh physical conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn our field experience, proximity probes often fail due to joint strain and fluid ingress along cable paths. The \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 330140-08-15-02-00\u003c\/strong\u003e\u003c\/span\u003e solves these failure points with integrated Viton O-ring seals and high-tensile cable locking. When retrofitting older turbomachinery, technicians benefit from its consistent 7.87 V\/mm linear output. This output matches existing 3300 XL Proximitor Systems without requiring field recalibration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330140-08-15-02-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL 8 mm System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEddy Current Proximity Probe (Without Armor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 inches (Option 08)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 meters \/ 4.9 feet (Option 15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable (Option 02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm \/ 80 mils (starts at ~0.25 mm gap)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity \/ ISF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) ±5% (5m system at 0°C to +45°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity \/ DSL Deviation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than ±0.025 mm (±1 mil) over linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Resistance (RPROBE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.73 ± 0.50 Ω (Center conductor to outer conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Body Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +350°F) standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViton O-ring sealing; less than 3% ASF shift at 93% RH (IEC 68-2-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC \u0026amp; Noise Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShielded coaxial architecture minimizes external industrial RFI\/EMI interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain minimum target area clearance around the tip to prevent target side-effects.\u003c\/li\u003e\n\u003cli\u003eEnsure precise mechanical mounting using appropriate brackets to prevent gap drift.\u003c\/li\u003e\n\u003cli\u003eTighten the ClickLoc coaxial connector firmly to maintain low contact resistance.\u003c\/li\u003e\n\u003cli\u003eAvoid bending cable tighter than minimum bend radius limits during installation.\u003c\/li\u003e\n\u003cli\u003eAvoid exposing seals below -34°C to prevent pressure seal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCalibration and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify DC resistance across conductors matches 7.73 ± 0.50 Ω during routine checks.\u003c\/li\u003e\n\u003cli\u003eCheck probe tip surfaces regularly for foreign particle build-up or mechanical abrasion.\u003c\/li\u003e\n\u003cli\u003eValidate output voltage linearity across the 80 mil gap using a spindle micrometer.\u003c\/li\u003e\n\u003cli\u003eInspect ClickLoc connection points for moisture or contamination during turnarounds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFully compatible with standard \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL 5 Meter Systems\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eConnects seamlessly to matching 3300 XL extension cables and Proximitor Sensors.\u003c\/li\u003e\n\u003cli\u003eBackwards compatible with legacy 3300 series monitor racks and signal channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications and Approvals\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard Option 00 (No special agency approvals required for general safe zones).\u003c\/li\u003e\n\u003cli\u003eManufactured under ISO 9001 certified quality control systems.\u003c\/li\u003e\n\u003cli\u003eMeets IEC 68-2-3 environmental and humidity testing standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft radial vibration monitoring on high-speed steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eAxial thrust position measurement on boiler feed pumps and multi-stage compressors.\u003c\/li\u003e\n\u003cli\u003ePhase reference (Keyphasor) speed tracking on industrial gearboxes and generators.\u003c\/li\u003e\n\u003cli\u003eEccentricity and thermal expansion tracking on heavy rotating plant assets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Warranty, and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e 100% Brand New and original factory packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-Month full coverage warranty included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Time:\u003c\/strong\u003e Fast processing, ships within 24-48 hours from stock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Logistics:\u003c\/strong\u003e Express shipping via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What cable option does this specific model use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330140-08-15-02-00\u003c\/strong\u003e\u003c\/span\u003e features option 02, which supplies a standard cable equipped with a ClickLoc miniature coaxial connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I install this probe in high-humidity machinery housings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, it resists humidity well, showing under 3% scale factor shift after 56 days at 93% RH under IEC standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What happens if ambient temperatures drop below -34°C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Exposing the probe seal below -34°C (-30°F) can cause premature failure of its internal pressure seal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How do I select the right system length for my installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Always match total probe and extension cable length to your Proximitor Sensor rating, such as a 5-meter total system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Why choose 8 mm probes over smaller 5 mm options?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: The 8 mm design features thicker PPS tip encapsulation and a sturdier body, providing greater mechanical resistance against physical damage.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330140_330141_330197_330198.png?v=1784785679\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013977727158,"sku":"330140-08-15-02-00","price":276.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330140_3_10a188a4-7c41-48e7-92e9-29679d90f81d.jpg?v=1785397020","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-330140-08-15-02-00-3300-xl-8mm-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}