{"product_id":"bently-nevada-330103-00-07-10-02-05-8mm-sensor-3300-xl-series-buy","title":"Bently Nevada 330103-00-07-10-02-05 8mm Sensor 3300 XL Series - Buy","description":"\u003ch3\u003e\u003cb\u003eProbe Architecture and Core Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #b91c1c;\"\u003e\u003cb\u003e330103-00-07-10-02-05\u003c\/b\u003e\u003c\/span\u003e is an advanced 8mm proximity probe engineered by \u003cspan style=\"color: #b91c1c;\"\u003e\u003cb\u003eBently Nevada\u003c\/b\u003e\u003c\/span\u003e under the \u003cspan style=\"color: #b91c1c;\"\u003e\u003cb\u003e3300 XL\u003c\/b\u003e\u003c\/span\u003e series. Designed for high-accuracy displacement and vibration telemetry, it incorporates patented TipCooler and ClickLoc connector technologies to ensure uncompromised signal fidelity. Its robust stainless steel case and PPS probe tip provide exceptional durability in harsh turbomachinery environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eModel Configuration Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConfiguration Parameter\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eSelected Suffix Option \u0026amp; Description\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBase Model \u0026amp; Thread Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e330103\u003c\/b\u003e = 3300 XL 8 mm Probe, M10 x 1 thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eUnthreaded Length Option\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e00\u003c\/b\u003e = 00 mm unthreaded portion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOverall Case Length Option\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e07\u003c\/b\u003e = 70 mm total case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTotal Cable Length Option\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e10\u003c\/b\u003e = 1.0 meter (3.3 feet) integrated cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConnector and Cable Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e02\u003c\/b\u003e = Miniature coaxial ClickLoc connector with standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAgency Approval Rating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e05\u003c\/b\u003e = CSA, ATEX, and IECEx hazardous area certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications \u0026amp; Performance Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePerformance Category\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eEngineering Specification Detail\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLinear Measuring Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils); spans from 0.25 to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRecommended Gap Setting\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-9 Vdc (approximately 1.27 mm or 50 mils from target face)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDC Resistance (RPROBE)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e7.59 +\/- 0.50 ohms from center conductor to outer conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-52C to +177C (-62F to +350F) for standard probe tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eField Wiring Compatibility\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) 3-conductor shielded triad cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Transmission Distance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 305 meters (1,000 feet) between probe and Proximitor sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eInstallation and Mechanical Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the probe using standard M10x1 metric threads with a maximum thread engagement of 15 mm.\u003c\/li\u003e\n\u003cli\u003eEnsure the Viton O-ring seal is undamaged to prevent differential pressure leaks between probe tip and case.\u003c\/li\u003e\n\u003cli\u003eAvoid exposing the probe tip to temperatures below -34C during installation to prevent pressure seal degradation.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring away from high-voltage power conduits to minimize electromagnetic induction noise.\u003c\/li\u003e\n\u003cli\u003eCalibrate the system gap voltage precisely to -9 Vdc using a digital voltmeter prior to machine startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Capabilities and Asset Protection\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eContinuous monitoring of output voltage shifts allows engineers to detect rotor unbalance, shaft bow, and journal bearing wear before catastrophic failure occurs. The linear output scale factor of 7.87 mV\/um (200 mV\/mil) ensures precise dynamic tracking. Sudden changes in the DC gap voltage indicate mechanical rub conditions or mechanical loosening within the probe bracket assembly.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTarget Equipment and Application Scenarios\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge Steam, Gas, and Hydroelectric Turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal and Axial Process Air Compressors\u003c\/li\u003e\n\u003cli\u003eCritical Industrial Boiler Feed Pumps and High-Speed Fans\u003c\/li\u003e\n\u003cli\u003eLarge Electric Motors and Generator Sets\u003c\/li\u003e\n\u003cli\u003eGearboxes and Expander-Compressor Trains in Chemical Plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eCompliance and Hazardous Area Approvals\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX and IECEx intrinsically safe classifications for Zone 0 (Ex ia IIC T5...T1 Ga).\u003c\/li\u003e\n\u003cli\u003eCSA Class I, Division 1, Groups A, B, C, D and Class I, Zone 0 hazardous locations.\u003c\/li\u003e\n\u003cli\u003eNon-incendive ratings for Class I, Division 2 and Zone 2 explosive atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eComparative Selection Analysis\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen evaluating alternative system designs, engineers frequently compare options based on cable length and unthreaded body specifications. For an alternative configuration featuring an extended 150 mm case length and 3.0-meter cable arrangement, review the \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330103-03-10-15-01-00-bently-nevada-3300-xl-8mm-proximity-probe-sensor\"\u003e\u003cb\u003e330103-03-10-15-01-00\u003c\/b\u003e\u003c\/a\u003e model. While the subject model is optimized for compact machinery brackets with its 70 mm case and 1.0 m lead, the comparative option suits thicker mounting walls and extended penetration depths.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eInstrumentation specialists utilizing the \u003cspan style=\"color: #b91c1c;\"\u003e\u003cb\u003e330103-00-07-10-02-05\u003c\/b\u003e\u003c\/span\u003e observe that maintaining clean coaxial connector interfaces is vital for preventing high-frequency signal attenuation. For example, applying protective rubber boots over ClickLoc connections in oily turbine enclosures prevents moisture ingress and eliminates erratic vibration spikes on the supervisory control panel.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eLogistics, Fulfillment, and Warranty\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRapid order processing and dispatch within 24 to 48 hours of purchase confirmation.\u003c\/li\u003e\n\u003cli\u003eSecure international transport channels coordinated via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade antistatic and shock-absorbent packaging to prevent transit damage.\u003c\/li\u003e\n\u003cli\u003eFully backed by a comprehensive 12-month manufacturer replacement warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eBuying Guide and Engineering FAQ\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: What is the primary function of the ClickLoc miniature coaxial connector?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides a secure, vibration-resistant mechanical lock while maintaining proper electrical shielding to prevent signal degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Why is the recommended static gap setting established at -9 Vdc?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: It centers the probe operating point precisely in the middle of its 2.0 mm linear range to accommodate full peak-to-peak vibration excursions.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Can this probe be tested for pressure sealing before field deployment?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Probes are not pressure tested as standard factory procedure, but custom testing can be requested for high-pressure casing penetrations.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How does cable length affect overall system frequency response?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Field wiring extensions up to 305 meters introduce minor high-frequency signal roll-off, which must be verified against system manufacturer attenuation curves.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What precautions should be taken when tightening the M10x1 probe case thread?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Do not exceed the 15 mm maximum thread engagement limit, and use a calibrated torque wrench to prevent stripping machine mounting holes.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_4dbdd848-d340-4da7-8f4b-5538f195a28f.png?v=1785135121\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45014017310902,"sku":"330103-00-07-10-02-05","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330103_1_77eba446-5cc4-47ea-aebe-982f2db61602.jpg?v=1788427064","url":"https:\/\/www.plcsparehub.com\/products\/bently-nevada-330103-00-07-10-02-05-8mm-sensor-3300-xl-series-buy","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}